EN-V233 – 5005 – AA Installation and use of built-in Visio call panel EEN-PIVIV3GB  

Page 8 / 12 

C) 

C

ONFIGURATION WITH AN 

I

NTRACODE 

EEN-CIC12

 CENTRAL UNIT

 

 

 

 
 
 

 

 

 
-  How do I enter settings mode? 

o

  Check that the welcome message is scrolling on the LCD 

o

  Press the 

֠

֠

֠

֠

 key until the "Enter password" menu appears. 

o

  Type the serial number of the EEN-CIC12 central unit (7xxxxxx3). 

o

  Validate with the 

֠

֠

֠

֠

 key« You are in menu settings mode" 

-  To exit settings mode: 

o

  Press the   arrow key several times until you return to the scrolling message. 

 

Menu options in settings mode: 

Setting 
the clock
 

 

Date: 28/01/13 
Day: Monday
  

Numeric keys for date entry 
Key  to select day 

 

 

 


 

Time: 09:15 
Type: winter
  

Numeric keys for time entry 
Key   to select summer/winter season 

 

 

 


 

Accept remote 
time: YES
  

Key  to select YES or NO 

 

 

 

 

Door 
settings 
 

 

Door settings 
PB:NO Opening time: 
05s
 

Key  to select: NO or NC 
Numeric keys for door-opening time entry 

 

 

 


 

֠

֠

֠

֠

 or 

 

Key   to Exit  
Key 

֠

 to Validate 

 

 

 

 

Volume of 
call panels
 

 

Direct selection 
of the volume
 

Enables direct input via the keypad of the 
volume of the call panel connected 

 

 

 

 

INTERNET Update 
Request 

 

Request an Update?  

Key 

֠

 to Validate 

 

 

 

 

Check fitting 

 

Test number:  

Enables direct input of the telephone number 
via the keypad to call for test purposes. 

 

 

 

 

 

֠

֠

֠

֠

 

Start test procedure 

Warning: the "door settings" menu will appear only if switches 4 / 5 / 6 on the EEN-
CIC12 central unit are set to OFF.

 

Entering numbers 

Exit from menus or 
Return to scrolling menu 

Go into menus or Make a 
selection 

Validation  

"Save changes" 

Содержание EEN-PIVIV3GB

Страница 1: ...ef EEN CIC12 Ideal for installation near an entrance gate four opening methods are possible By using an authorised fob By typing in a specific trade code By calling a tenant using the call panel who then opens the door using a key on his her telephone Using a mobilekey You can select the tenant to call just by entering his her flat number on the keypad or by pressing the arrows Product description...

Страница 2: ...E GATE WITH THE 2 TYPES OF CENTRAL UNITS 6 E SCENARIO OF CONNECTING AN ENTRANCE GATE PLUS A BUILDING 6 EQUIPMENT CONFIGURATION 7 A GENERAL POINTS 7 B CONFIGURATION WITH A TENANTIAL CENTRAL UNIT EEN CEN12 7 C CONFIGURATION WITH AN INTRACODE EEN CIC12 CENTRAL UNIT 8 POST FITTING CHECK 9 D ON THE PANEL 9 E DOOR CONNECTION 9 F CALLS 9 G IN THE CASE OF A FITTING WITH A 3G UNIT 9 H IN THE CASE OF A FITT...

Страница 3: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3GB Page 3 12 DIMENSIONS AND ASSEMBLY A DIMENSIONS OF CALL PANEL ...

Страница 4: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3GB Page 4 12 B BUILT IN BOX DIMENSIONS ...

Страница 5: ...nel is installed with a 3G unit AUDIO or VIDEO or B FOR USE IN AUDIO CALLS ONLY Connect the following terminals up to the central unit Terminal Detail NB pair Power supply 1 D D Data 1 A A Audio 1 C FOR USE IN VIDEO CALLS Also connect the following terminals up to the V V VIDEO 1 terminals on the 3G unit Terminal Detail NB pair V V Video 1 EEN CIC12 EEN M3G EEN M3G EEN M3G EEN PIVIV3GB THE CENTRAL...

Страница 6: ...NNECTING AN ENTRANCE GATE PLUS A BUILDING It is mandatory to use an EEN CEN12 central unit with in this example an extension board Scenario Audio and Video calls from the entrance gate Only Audio calls can be made from the building entrance 4 2 6 6 6 Add an extension card doors 3 and 6 6 2 2 2 In this example door 4 remains available 41 49 and CRT Connections in red refer to Visio V V Connections ...

Страница 7: ...nu on the central unit With regard to the volume level you have 2 options in the Panel volume menu Direct selection of volume Enter a value between 1 and 4 corresponding to the sound level Settings on the Panels This menu starts a 15 minute timer During this time you can move between the call panel or panels connected to this central unit in order to adjust the sound level Step 1 Type in the keypa...

Страница 8: ...e 09 15 Type winter Numeric keys for time entry Key to select summer winter season Accept remote time YES Key to select YES or NO Door settings Door settings PB NO Opening time 05s Key to select NO or NC Numeric keys for door opening time entry or Key to Exit Key to Validate Volume of call panels Direct selection of the volume Enables direct input via the keypad of the volume of the call panel con...

Страница 9: ...t o Audio Call o Video Call Check that during the call the tenant can open the door by pressing the key on his her telephone See Test Procedure in the central unit guide G IN THE CASE OF A FITTING WITH A 3G UNIT If you use a 3G unit with your call panel you can see the signal reception level for the unit by pressing the 2 scrolling arrow keys on the display Depending on the situation you will see ...

Страница 10: ... the and or terminals Check cabling between the central unit and the call panel When swiping a badge the green LED on the reader lights up but the door does not open Relay on the central unit not working Cable to the door Check if relay sticks Check cabling between the central unit and the door If the call panel says Call in progress but the tenant cannot hear the visitor Incorrect cabling on the ...

Страница 11: ...e telephone network standards TS 103 021 and TR 103 000 Cabling The cables connected to the central unit must not be placed in the vicinity of other sources of electrical power e g mains power supply Operating warranty The call panel is guaranteed for a temperature range of between 20 C and 70 C and for relative humidity not exceeding 70 End of life product recycling The panel and its accessories ...

Страница 12: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3GB Page 12 12 B CERTIFICATE ...

Отзывы: