EN-V233
– 5005 – AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 5 / 12
CABLING
See EEN-CIC12 guide : V233 - 5002 - XX
See EEN-CEN12 guide: V233-5001-XX
A)
General points
POWER SUPPLY : The central unit supplies power to the call panel via the + / - terminals.
CABLING
:
Twisted pairs
– Diameter: 0.8 – Max. distance 100 metres.
Important note:
- The video function will only work if the call panel is installed with a 3G unit.
- If the call panel is installed with a PSTN line, only audio will work.
AUDIO
+
+
or
VIDEO
+
+
or
B)
For use in AUDIO calls only
Connect the following terminals up to the central unit:
Terminal
Detail
NB pair
+ / -
Power supply
1
D-+ / D-
Data
1
A+ / A-
Audio
1
C)
For use in VIDEO calls
Also connect the following terminals up to the V+ / V- (VIDEO 1) terminals on the
3G unit:
Terminal
Detail
NB pair
V+ / V-
Video
1
EEN-CIC12
EEN-
M3G
EEN-M3G
EEN-M3G
EEN-PVICBV3
EEN-PVICBV3
THE CENTRAL UNITS
THE CENTRAL UNITS
+
-
D+
D-
+ - D+ D-
V+
V-
A+
A-
Power supply: 12 / 24 V
– 2 to 4 A
Not supplied
+ - D+ D-
A+A-
V+
V-
EEN-
M3G
EEN-CEN12
+
-
D+
D-
A+
A-
Twisted pair
MANDATORY
for video
Twisted pair
recommended