Mechanical installation
j
| BA 14.0175−EN | 11/2007
18
4.2.3
Mounting of armature assembly of designs 1, 2 and 5
The armature assembly is shifted onto the shaft. The maximum permissible centre offset of
the shafts, dimension "tw" can be obtained from Tab. 1. The air gap s
air
adjusted using a feeler gauge.
Use shims for the exact air gap setting and for the compensation of wear.
(
Stop!
The armature assembly must be fixed axially.
14.105
14.115
s
ai
r
s
ai
r
Fig. 5
Size
s
air
x
INTORQ 14.105
INTORQ 14.115
[mm]
[mm]
t
k
t
w
b [mm]
t
w
b [mm]
06
0.2
±
0.05
0.04
0.2
0.1
24
0.16
18
08
0.2
±
0.05
0.05
0.3
0.1
26.5
0.16
20
10
0.2
±
0.05
0.06
0.3
0.1
30
0.16
22
12
0.3
±
0.1
0.07
0.3
0.1
33.5
0.2
24
16
0.3
±
0.1
0.09
0.4
0.2
37.5
0.2
26
20
0.5
±
0.15
0.11
0.4
0.2
44
0.2
30
25
0.5
±
0.15
0.14
0.5
0.2
51
0.3
35
Tab. 1