SETUP INSTRUCTIONS

Power: 

110-120 Volt AC

Amperage: 

6.0 A

Maximum working pressure: 

3.5 bar (50 psi)

Effective filtering area: 

0.13 m

2

 (1.44 ft

2

)

Maximum Flow Rate: 

10030 liters/hour (2650 gallons/hour)

Recommended filtering media: 

No. 20 silica sand or glass sand. Particle size 

(Not included)  

range 0.45 to 0.85 mm (0.018 to 0.033 inches). 

   

 Uniformity Coefficient less than 1.75.

Recommended filtering media quantity: 

No. 20 silica sand 45 Kg (100 Lbs) 

or glass 

  

sand 

32 Kg (70 Lbs).

Limited Warranty: 

see “Limited Warranty”

NOTE: 

NOT SUITABLE FOR USE WITH KCP-LOW -SALT AUTOMATIC SALTWATER 

SYSTEM (MODEL 6110/6220

)

The sand filter removes suspended particles but does not sanitize your pool. 

Pool chemistry is a specialized area and you should consult your local pool 

service specialist for details.

TOOLS REQUIRED:  One (1) Phillips screwdriver

Pump location and mounting:

•  The system must be installed on a solid level and vibration-free base.

•  Provide a location protected from the weather, moisture, flooding and    

  freezing temperature.

•  Provide adequate access, space and lighting for routine maintenance.

•  Pump motor requires free circulation of air for cooling. Do not install    

  the pump in a damp or non-ventilated location.
A team of 2 or more people is recommended for setting up this product.

Motor pre-filtering assembly setup:

1. 

Remove the sand filter and its accessories   

    from the packaging carefully and inspect for  

    any visible damage. If parts are damaged    

    contact your local service center listed at    

    the back of this owner’s manual.

2. 

In a counter-clockwise motion unscrew the   

    leaf trap cover 

(14) 

from the pre-filter 

    housing. Take out the basket 

(16) 

and filter   

    housing nut 

(17) (see drawing 10)

3.

  Connect the pre-filter housing to the motor    

    water inlet. Note

: Align the connector in the   

    pre-filter housing with the water inlet on the   

   motor 

(see drawing 11)

.

10

11

35

17

16

14

Содержание SF20110

Страница 1: ...at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may result in updates to the instruction...

Страница 2: ...CONTENTS Warnings 3 Parts List References 4 8 Setup Instructions 9 16 Product Specifications 11 Operating Instructions 17 19 Intex Pools Operating Time Table 20 Non Intex Pools Operating Time Table 21...

Страница 3: ...unit to electric supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Do not use an appliance leakage current i...

Страница 4: ...LISH 7 5 X 10 3 PANTONE 295U 06 26 2012 127 SAVE THESE INSTRUCTIONS Page 4 PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale English PARTS LIST 7 1 9 4 5 2 6...

Страница 5: ...ANTONE 295U 06 26 2012 127 SAVE THESE INSTRUCTIONS Page 5 English PARTS LIST continued PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale 23 25 22 24 26 27 28...

Страница 6: ...tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a...

Страница 7: ...S REFERENCE PARTS REFERENCE continued Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only...

Страница 8: ...ERCONNECTING HOSE 1 11535 14 LEAF TRAP NUT 1 11479 15 LEAF TRAP O RING 1 11232 16 BASKET 1 11260 17 FILTER HOUSING NUT 1 11261 18 L SHAPE O RING 1 11412 19 SEDIMENT RELEASE VALVE 1 10460 20 VALVE O RI...

Страница 9: ...the inside of the pool liner insert the connector 26 into one of the pre cut holes with the washer remaining on the connector to be placed against the inside of the liner wall 4 Before assembly lubri...

Страница 10: ...ut 24 facing the outside wall of the liner in a clockwise motion screw the strainer nut 24 back onto the threaded connector 26 see drawing 6 5 Finger tighten the adjustable pool inlet nozzle 27 and th...

Страница 11: ...our local pool service specialist for details TOOLS REQUIRED One 1 Phillips screwdriver Pump location and mounting The system must be installed on a solid level and vibration free base Provide a locat...

Страница 12: ...14 2 NOTE Ensure the pre filter housing water inlet hose connection is facing towards the pool IMPORTANT Some countries especially in the European community require the product to be secured to the gr...

Страница 13: ...top of the center pipe Pour the sand into the tank at a slow rate see drawing 15 2 Fill the tank approximately half way remove the sand shield 6 from the top see drawing 16 3 Evenly distribute the sa...

Страница 14: ...o valve is aligned with the motor outlet see drawing 20 SETUP INSTRUCTIONS SETUP INSTRUCTIONS continued WARNING Improper tank valve and clamp assembly could cause the valve and clamp to blow off and c...

Страница 15: ...inlet nozzle Ensure the hose nuts are securely tighten 3 The third hose connection port drain waste outlet on the 6 way valve shall be directed to a proper draining receptacle using a hose or pipe no...

Страница 16: ...is in place Connect adaptor B 28 to plunger valve union 3 Remove wall plug and then insert the strainer 29 31 into the lower position of protruding hose connection and the nozzle 29 30 into the upper...

Страница 17: ...ng 23 Normal filtration and regular vacuuming of pool From pump through filter media to pool BACKWASH see drawing 24 Reverses water flow to clean filter media From pump through filter media to valve w...

Страница 18: ...per draining receptacle 3 Ensure the pump is off depress the 6 way valve and turn it to the BACKWASH position see drawings 24 29 IMPORTANT To prevent damage to the 6 way valve always depress the valve...

Страница 19: ...acuuming device attached to the system and the pressure gauge reading is in the yellow zone it is time to backwash the sand media see BACKWASH under initial startup and operation section Vacuuming dev...

Страница 20: ...48 549cm x 122cm 5455 20647 2 ROUND METAL FRAME POOL 18 x 48 549cm x 122cm 6423 24311 4 21 x 52 640cm x 132cm 9533 36082 4 24 x 52 732cm x 132cm 12481 47241 6 ULTRA FRAME POOL 18 x 48 549cm x 122cm 64...

Страница 21: ...mp with above ground pools Water Capacity Sand filter pump operating time For one cycle Gals Liters Hours 2 2 2 4 4 4 4 6 6 6 6 6 8 8 8 8 12 12 12 12 12 12 12 12 4000 4440 5000 6000 7000 8000 9000 100...

Страница 22: ...opening the sediment release valve 19 located on the lower side of the pre filter housing see drawing 32 4 In a counter clockwise motion unscrew the leaf trap cover 14 then remove the basket 16 and l...

Страница 23: ...Fahrenheit POOL CARE CHEMICALS All pools require care to keep the water clear and hygienically clean With proper chemical control your filter will help attain this objective Consult your pool supply...

Страница 24: ...nd ensure the o ring is in place Clean sand tank o ring with garden hose water Tighten the clamp with wrench supplied Contact Intex service center Tighten reinstall hose nut Ensure o ring L shape o ri...

Страница 25: ...Super chlorinate with shock treatment Correct pH to your pool store s recommended level Vacuum pool bottom Maintain proper chlorine level Adjust pH level to the recommended level Run filter until wate...

Страница 26: ...ompetent adult should be appointed as a lifeguard or water watcher especially when children are in and around the pool Learn to swim Take the time to learn CPR and first aid Instruct anyone who is sup...

Страница 27: ...and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried fort...

Отзывы: