MAINTENANCE AND CHEMICALS

Water Sanitation

The spa owner must regularly check and keep the spa water sanitized with scheduled maintenance (daily, if 

necessary). Adding sanitizer and other chemical will control bacteria and viruses present in the spa water. 

The maintenance of a proper water balance through appropriate use of sanitizers is the single most important 

factor in maximizing the life and appearance of the spa tub as well as ensuring clean, healthy and safe water. 

Proper technique is important for water testing and treating the spa water. See your pool/spa professional for 

chemical, sanitizer, test kits and testing procedures questions.

CATUTION:

 ALWAYS FOLLOW THE CHEMICAL MANUFACTURER’S DIRECTIONS, 

AND THE HEALTH AND HAZARD WARNINGS.

Do not add chemicals if the spa is occupied. This can cause skin or eye irritation.

 Concentrated chlorine 

solutions can damage the spa tub. In no event is Intex Recreation Corp., Intex Development Co. Ltd., their 

related companies, authorized agents and service centers, retailers or employees liable to the buyer or any other 

party for costs associated with the loss of spa water, chemicals or water damage.

Maintenance of Spa Water and Cartridge

Protect all the spa occupants from possible water-related illnesses by keeping the spa water clean and sanitized. 

Always practice good hygiene. To ensure proper spa water quality follow these procedures:

1.

  Inspect and clean the 

fi

 lter cartridge every day, and change the 

fi

 lter 

 

cartridge every 3 days.

 a.

  Unscrew the cartridge housing assembly from the spa tub wall and 

  remove 

the 

cartridge 

(see drawing 11)

.

 

b.

  Use a garden hose to rinse off the cartridge. If the cartridge remains 

 

 

soiled and discolored it should be replaced. Keep spare cartridges 

  on 

hand.

 

c.

  Reinstall the clean cartridge back into the cartridge housing and  

 

 

replace the cartridge housing assembly back onto the spa tub wall.

2.

  Change the spa water every 3 days. See “Spa Tub Drainage” and “Spa 

 

Tub Cleaning” sections for details.

3.

  Use spa chemicals to maintain proper water chemistry. Spa damage 

 

resulting from misuse of chemicals and mismanagement of spa water 

 

is not covered by the warranty.

4.

  All occupants must shower before entering the spa.

Water Chemistry Balance

Maintain the spa water pH level between 7.2 and 7.8, total alkalinity level between 80 and 120 ppm and free 

chlorine level between 2 to 4 ppm. Use the included test strips to test the spa water chemistry before each use 

of the spa and continue to test the water no less than once a week.

The Test Strips can test the “Free Chlorine”, “pH”, “Total Alkalinity” and “Calcium Hardness” levels at the same 

time:

1.

  Dip the entire strip into the water and remove immediately.

2.

  Hold the strip level for 15 seconds. Do not shake excess water from the strip.

3.

  Compare the strip pad to the color chart on the packaging label. If necessary, adjust the chemical level in 

 

the pool water.

NOTE:

 Check the expiry date of the test kit as the test results may be inaccurate if the kit is used after that date.

Low pH will damage the spa tub and pump. Damage resulting from chemical imbalance is not covered by the 

warranty.

Use the included chemical 

fl

 oater dispenser to administer chlorine [chemical tablet size: less than 1” (2.5 cm) 

diameter] into the spa water. Add 1 tablet into the dispenser. Always follow the chemical manufacturer’s 

directions. Remove the chemical 

fl

 oater dispenser when the spa is in use.

Never let chlorine come in contact with the spa tub if it is not completely dissolved. 

IMPORTANT: 

Press the          button on the spa control panel to activate the jet system and help dissolve the 

chemicals into the water.

Never mix chemicals together. Add the chemicals to the spa water separately. Thoroughly dissolve each 

chemical before adding another one to the water.

WARNING

Always unplug this product from the electrical outlet before removing, cleaning, 

servicing or making any adjustment to the product.

11

14

12

13

Содержание PureSpa SPJ-H-20-1C

Страница 1: ...d Intex Development Co Ltd Intex Trading Ltd Intex Recreation Corp All rights reserved Tous droits réservés Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprimé en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilisées dans certains pays sous licence de Marcas registradas utilizadas en algunos países de...

Страница 2: ...O SPA JET HARD WATER ENGLISH 7 5 X 10 3 PANTONE 295U 07 26 2016 English Page 2 Warning 3 5 Parts 6 7 Set up 8 11 Operation 12 LED Code Chart 13 Maintenance and Chemicals 14 19 Storage 19 Troubleshooting 20 Warranty 21 TABLE OF CONTENTS ...

Страница 3: ...injury a The water in a spa should never exceed 40 C 104 F Water temperatures between 38 C 100 F and 40 C 104 F are considered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant w...

Страница 4: ... F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effects of hyperthermia include failure to perceive heat failure to recognize the need to exit spa or hot tub unawareness of impending hazard fetal damage in pregnant women physical inability to exit the spa or hot tub and unconsciousness resulting in the dange...

Страница 5: ...anty Always keep plug dry plug in with wet plug is definitely forbidden The plug of SPA must be directly connected only to a earthed socket outlet from a fixed electrical installation To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electrical supply provide a properly located outlet Do not attempt to plug in or unplug this ...

Страница 6: ...English Page 6 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale 10 11 18 17 19 21 5 22 6 3 4 12 13 15 16 20 14 2 23 7 27 26 25 A B 8 1 A B 9 24 ...

Страница 7: ...RE GAUGE 1 11741 6 CONTROL PANEL BOLT WRENCH 1 11053 7 SPA INFLATION HOSE 1 11830 8 SPA CONTROL INLET OUTLET O RING 2 11788 9 ELECTRIC AIR PUMP 1 11962 10 SPA DRAIN PLUG 1 11696 11 SPA DRAIN VALVE ADAPTOR 1 11718 12 FILTER CARTRIDGE HOUSING 1 11798 13 FILTER CARTRIDGE 2 11692 14 FILTER CARTRIDGE HOUSING LID 1 11797 15 INLET PLUG 1 11739 16 SPA TUB 1 12086 17 SPA COVER 1 11784 18 SPA COVER INFLATAB...

Страница 8: ...e full weight of the filled spa with the maximum number of occupants Check with a qualified contractor or a structural engineer to verify this requirement Make sure the floor is water resistant and non slip surface Do not install the spa on carpet or other materials that will be damaged by moisture condensation Do not install the spa indoors on a second floor above finished living space due to the...

Страница 9: ... provided bolt wrench 6 to secure the control panel see drawing 2 3 Plug the spa control unit into an electrical outlet Page 9 For indoor inflation Inflate the Spa Tub Wall 1 Take out the ground cloth 19 and spread it over the cleared area Then spread out the spa liner over the ground cloth and point the drain valve towards a suitable draining area 2 Assemble the inflation pumps by aligning the ri...

Страница 10: ...er 1 Open the inflation valve and insert one end of the inflation hose 7 into the valve the other end to the electric air pump turn on the pump to inflate until the air bladder is firm to the touch but not hard see drawing 7 2 Disconnect the inflation hose 7 from the valve and the inflation air pump 3 Close and recess the inflation valve NOTE If there is a need to add some air to the spa tub wall ...

Страница 11: ...on the inside of the spa wall Do not over fill the spa Never move the spa tub with water inside and or with the control base attached to the spa as the spa or control base may be damaged WARNING Never pour water with a temperature higher than 40 C 104 F into the spa directly It is recommended to fill the spa tub with lukewarm water for quick heating and energy saving 5 Place the spa cover and spa ...

Страница 12: ...uttons will cause the LED to flash When flashing you can adjust to the desired temperature setting If you hold these buttons down the values will rapidly increase or decrease The new and desired temperature setting will remain on the LED display for 5 seconds to confirm the new value NOTE The default temperature is 20 C 68 F NOTE Temperature adjustment ranges from 20 C 68 F to 40 C 104 F Water Fil...

Страница 13: ...emperature is below 4 C 39 F we recommend not to use the spa Turn off and unplug the control unit add some warm water to raise the spa water temperature above 5 C 41 F then press the button to heat up the water to the desired temperature If problem persists contact Intex Service Center E95 Water temperature is around 50 C 122 F Turn off and unplug the control unit When the water has cooled down pl...

Страница 14: ...e housing and replace the cartridge housing assembly back onto the spa tub wall 2 Change the spa water every 3 days See Spa Tub Drainage and Spa Tub Cleaning sections for details 3 Use spa chemicals to maintain proper water chemistry Spa damage resulting from misuse of chemicals and mismanagement of spa water is not covered by the warranty 4 All occupants must shower before entering the spa Water ...

Страница 15: ...n cloudy water shorter filter heater runs eye skin irritation high chlorine demand Calcium Hardness CaCO3 refers to the amount of calcium and magnesium dissolved in the water Result if too low Difficulty balancing water corrosion of metal components eye skin irritation and water foaming Result if too high Scale formation cloudy water eye skin irritation difficulty balancing water and filter heater...

Страница 16: ...you can also add 0 269 Lb 121 g of sodium bisulfate or 0 101 qt 96 ml of muriatic acid If the reading is more than 240 ppm you can add sodium bisulfate or muriatic acid to the water drop by drop until the test strip indicates a 240 ppm reading then add 0 528 Lb 238 g of sodium bisulfate or 0 202 qt 192 ml of muriatic acid NOTE After adjustment retest the water after 24 hours and adjust again if ne...

Страница 17: ...softener mix the spa hard water with the soft water according to the water volume ratio chart to lower the calcium hardness Initial level 1000 ppm 500 ppm 350 ppm 250 ppm Desired level 100 ppm Water Volume Ratio Vhard water Vsoft water 1 9 1 4 2 5 2 3 Lowering Calcium Hardness Using Soft Water Volume Total Alkalinity From To 6 8 7 2 210 gal 800 L 120 ppm 0 541 Lb 243 g 80 ppm 0 361 Lb 163 g Raisin...

Страница 18: ...on to wipe away any soil or stains on the inside of the spa wall Rinse thoroughly before refilling with clean water IMPORTANT Do not use steel wool hard brushes or abrasive cleaners Spa Tub Air Valve Fastening Check the spa tub air valve for leakage and tightness before use If air is leaking from the air valve use the provided wrench 22 to tighten the air valve as follow 1 Make sure the spa tub is...

Страница 19: ...ion port b Connect the inflation hose 7 to the inflation pump adaptor c Insert the other end of the inflation hose 7 into the valve and turn to the right to lock it in position Switch on the electric air pump to deflate 4 Make sure all the spa components and accessories are thoroughly clean and dry before storage Air dry the spa tub in the sun for an hour before folding 5 Fold the spa tub loosely ...

Страница 20: ...ge in time Check and clean filtration inlet and outlet regularly Contact Intex Service Center WATER NOT CLEAN Cartridge assembly not properly attached Insufficient filtering time Dirty filter cartridge Improper water maintenance Filtration inlet and outlet clogged Ensure the cartridge assembly is properly attached Increase filtration time Clean or replace the filter cartridge in time Keep the spa ...

Страница 21: ...e provisions of the warranty the item will be repaired or replaced with the same or comparable item at Intex s choice at no charge to you Other than this warranty and other legal rights in your country no further warranties are implied To the extent possibly in your country in no event shall Intex be liable to you or any third party for direct or consequential damages arising out of the use of you...

Отзывы: