Intex Newel Скачать руководство пользователя страница 2

 

LEDINST | REV B

 

2.

 

Run Cabling to Planned Layout 

Lay all cabling according to planned layout. You may wish to leave extra length at each intersection to allow for minor 
field adjustments. If running wiring through railing, ensure that rail caps are not installed until all connections are made 
and verified. 

 

3.

 

Connect all Caps 

Set caps in place and make all connections. Locate the packs of gel connectors provided with each cap. Note that each 
cap connected will require 2 connectors. For a typical connection - split the two-conductor wire and include a lead from 
the source, cap, and continued run on each connector as shown below. 

Note: To use the gel connectors, wires do not 

need to be stripped. Simply insert all 3 leads fully into the connector and use a pair of pliers to clamp the blue cap down 
onto the leads until it clicks into place.

 

 

4.

 

Install and Connect Transformer 

Follow the transformer’s included instructions to install it in a suitable location. Ensure it is unplugged before connecting 
the wiring to the terminals. Using a pair of wiring strippers, strip the source leads about ½” back before inserting them 
into the terminals and snapping them in place. 

Note: INTEX Millwork Solutions recommends using the 15V terminals only 

on the power supply. If you are unable to evenly balance the number of lights per terminal, you may wish to connect the 
smaller run of lights to the 12V terminal to more evenly balance the brightness. 

 

5.

 

Verify Installation and Finalize 

Once all connections are made, plug the power supply in and turn it on to ensure all lights are properly connected and 
are functional. Once verified, tuck cap wiring into newels and secure caps to newels using latex caulk. DO NOT USE PVC 
GLUE TO ATTACH CAPS TO NEWEL. 

If necessary, finish rail installation by applying all rail caps in accordance with their provided installation instructions. 

 

 

Отзывы: