SALT TABLE FOR COMMON NON-INTEX POOLS

OPERATING TIME TABLE FOR COMMON NON-INTEX POOLS (WITH CYANURIC ACID)

Water Capacity

Salt Needed for Startup

Salt Needed when
Low Salt Detected

(CODE “91”)

(Gals)

(Liters)

(Lbs)

(Kgs)

(Lbs)

(Kgs)

            2000 7500 

50 20 

10 5

 4000 

15000 

100 

45 

25 

10 

 6000 

22500 

150 

65 

40 

20

 8000 

30000 

200 

90 

55 

25

 10000 

37500 

250 

110 

70 

30

 12000 

45500 

300 

135 

80 

35

 14000 

53000 

350 

160 

95 

45

Salt Needed for Startup 

(Lbs) 

Salt Needed for Startup 

(Kgs)

Salt Needed when 

Low Salt Detected (Lbs) 

Salt Needed when 

Low Salt Detected (Kgs)

Water Capacity (Gals) x 0.025

Water Capacity (Liters) x 0.003

 

Water Capacity (Gals) x 0.0067

Water Capacity (Liters) x 0.0008

Water Capacity

Operating Time (hours)

at different ambient/air temperatures

(Gals)

(Liters)

10  -  19°C                   

(50 - 66°F)

20 - 28 °C 

(68 - 82 °F)

29 - 36 °C

(84 - 97 °F)

2000

4000

6000

8000

10000

12000

14000

7500

15000

22500

30000

37500

45500

53000

7

2

3

4

5

6

7

8

3

4

5

6

7

CYANURIC ACID TABLE FOR COMMON NON-INTEX POOLS

Water Capacity

Cyanuric Acid Needed for Startup

0.03g/L (30ppm)

(Gals)

(Liters)

(Lbs)

(Kgs)

2000

4000

6000

8000

10000

12000

14000

7500

15000

22500

30000

37500

45500

53000

0.23

0.45

0.68

0.90

1.13

1.37

1.59

0.5

1.0

1.5

2.0

2.5

3.0

3.5

SALT CALCULATION FORMULA FOR ALL POOLS

Содержание L ZS6220

Страница 1: ...7 2017 Intex Marketing Ltd Intex Development Co Ltd Intex Trading Ltd Intex Recreation Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in Ch...

Страница 2: ...lt Table 9 Intex Pools Cyanuric Acid Table 10 Intex Pools Operating Time Table 11 Non Intex Pools Salt Table 12 Non Intex Pools Cyanuric Acid Table 12 Non Intex Pools Operating Time Table 12 Operating...

Страница 3: ...installed Do not bury the electrical cord Locate the cord where it will not be damaged by lawn mowers hedge trimmers and other equipment If the supply cord is damaged it must be replaced by the manufa...

Страница 4: ...t may vary Not to scale When ordering parts be sure to quote the model number and part numbers 4 1 3 9 8 7 6 5 2 10 2 12 11 REF NO DESCRIPTION QTY SPARE PART NO 1 ADAPTOR A WITH THREADED COLLAR OPTION...

Страница 5: ...rts destroying bacteria and algae It also oxidizes all other organic materials Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into...

Страница 6: ...filter pump 1500 4000 gph 5680 15140 lph to drive the water and function properly The Ozone Saltwater System must be installed as the last piece of pool equipment in the water return line to the pool...

Страница 7: ...pump outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Ozone Saltwater System to the pump connect it to the pool This...

Страница 8: ...ue only to pool water being physically removed from the pool Salt is not lost due to evaporation Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Ozone Saltwater Syste...

Страница 9: ...549cm x 132cm 20 x 48 610cm x 122cm 22 x 52 671cm x 132cm 24 x 52 732cm x 132cm 26 x 52 792cm x 132cm 15 8 x 49 478cm x 124cm 16 8 x 49 508cm x 124cm 18 8 x 53 569cm x 135cm 18 x 10 x 42 549cm x 305c...

Страница 10: ...x 122cm 7947 30079 2 0 0 9 22 x 52 671cm x 132cm 10472 39637 2 6 1 2 24 x 52 732cm x 132cm 12481 47241 3 1 1 4 26 x 52 792cm x 132cm 14667 55515 3 7 1 7 GRAPHITE GRAY PANEL Pool SET 15 8 x 49 478cm x...

Страница 11: ...18 x 52 549cm x 132cm 20 x 48 610cm x 122cm 22 x 52 671cm x 132cm 24 x 52 732cm x 132cm 26 x 52 792cm x 132cm 15 8 x 49 478cm x 124cm 16 8 x 49 508cm x 124cm 18 8 x 53 569cm x 135cm 18 x 10 x 42 549cm...

Страница 12: ...artup Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0...

Страница 13: ...timer will now activate your Ozone Saltwater System at the same time each day for the number of hours you have set NOTE The Ozone Saltwater System will not operate if the filter pump is not operating...

Страница 14: ...LEEP indicator on the control panel lights up and the LED display flashes 93 The system is now in Stand By mode After a while it shuts down and sets itself in a Power Saving mode The system will autom...

Страница 15: ...aining 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaini...

Страница 16: ...your local authorities to determine if there is a regulation in your area regarding above the ground swimming pool filter pumps If yes then the product can be mounted to a platform using the two hole...

Страница 17: ...its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell has a self cleaning function incorporated into the electronic control s programming In most cases this self cleaning a...

Страница 18: ...the flow sensor from the electrolytic cell 9 housing 5 Pour kitchen grade vinegar into the electrolytic cell 9 to immerse the titanium electrodes Soak for 1 hour 6 Open one side of the cell cover 11...

Страница 19: ...label If necessary adjust the chemical level in the pool water It is very important to use the proper technique when testing the water s chemical level Read and follow the written strip instructions c...

Страница 20: ...ffect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved in the water Result if...

Страница 21: ...manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special attention to the hinge See Maintenance Plug the...

Страница 22: ...propriate stabilizer See Cyanuric Acid table Use a pool cover when the pool is not in use and or when the unit is operating Increase the daily Ozone Saltwater System operating time See Operating Instr...

Страница 23: ...duct package and package insert warnings and instructions Remember however that product warnings instructions and safety guidelines cover some common risks of water recreation but do not cover all ris...

Страница 24: ...er will inspect the item and determine the validity of the claim If the item is covered by the provisions of the warranty the item will be repaired or replaced with the same or comparable item at Inte...

Отзывы: