OPERATING INSTRUCTIONS
• Risk of electric shock. Connect this product only to a grounding type receptacle protected
by a ground-fault circuit interrupter (GFCI) or residual current device (RCD). Contact a
qualified electrician if you cannot verify that the receptacle is protected by a GFCI/RCD.
Use a qualified electrician to install the GFCI/RCD, which has a maximum rate of 30 mA.
Do not use a portable residual current device (PRCD).
•
To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or
converter plugs to connect unit to electric supply; provide a properly located outlet.
•
Do not attempt to plug in or unplug this product while standing in water or when your
hands are wet.
• Never operate this product above the maximum working pressure stated on the filter tank.
• Always switch off pump before changing the 4-way valve position.
• Operating this product without water flowing through the system can cause a build up of
hazardous pressure which can result in an explosive situation, serious injury, property
damage or death.
• Never test this pump with compressed air. Never operate the system with water
temperature above 35°C (95°F).
WARNING
Valve Position
Function
Water Flow Direction
FILTER
(see drawing 14)
Normal filtration and regular vacuuming
of pool
From pump through filter media to
pool
BACKWASH
(see drawing 15)
Reverses water flow to clean filter
media
From pump through filter media to
valve waste/drain outlet
RECIRCULATE
(see drawing 16)
For circulating water back to pool
without going through the filter media
From pump through valve to
pool bypassing the filter media
DRAIN
(see drawing 17)
For vacuuming directly to waste,
lowering pool level or to drain the pool
From pump to valve waste/drain
outlet bypassing the filter media
4-way valve positions and function:
Control panel description:
ON / OFF button
LOCK / UNLOCK button
TIMER button
LED Reading
Definition
00
Stand-by mode (start-up / operating cycle finished)
01
Minimum operating hour (1 hour remaining)
02-11
Operating hours (2 – 11 hours remaining)
12
Maximum operating hours (12 hours remaining)
FP
Timer OFF (pump operating continuously)
•
Power saving mode
14
17
15