ALARM CODES
No chlorine production will occur if “Low Water Flow”, “Low Salt Level” or “High Salt
Level” are detected. If any of these conditions occur then the Saltwater System will
sound an alarm that indicates chlorine production has stopped. A buzzer will sound
and a Code (see below) will keep flashing on the LED for 1 hour. The buzzer and
flashing light will end after one hour and the Saltwater System will go to Power
Saving Mode. If this occurs then press any button ( or ) to view the code of
the original problem so that it can be corrected.
Turn off the power of the unit and follow the solutions below to solve the problem.
Turn on the unit again by following the “Operating Instructions”.
AA
LLAA
RR
MM
SS
Code
Cause
Remedy
Flashing Buzzer
1. Circulation line
blocked.
2. Incorrect inlet and
outlet hose
direction.
3. Scale on the flow
sensor.
4. Flow sensor cord
is loose.
5. Flow sensor failure.
1. Dirt or scale on
titanium plates.
2. Low salt level / No
salt.
3. Possible electrolytic
cell failure.
1. High salt level.
• Ensure the plunger valves are
opened (if any).
• Ensure your filter cartridge, cell
are clear from debris and dirt. See
“Maintenance”.
• Release all trapped air in the
circulation line. See Filter Pump
Manual.
• Check for the direction of water
inlet and water outlet hose. Reverse
the hoses if necessary. See “Set
Up Instructions”.
• Ensure the flow sensor (especially
the hinge) is clean. See
“Maintenance”.
• Check for flow sensor loose or not
connected properly. Plug the flow
sensor firmly into the flow sensor
receptacle.
• Contact Intex Service Center for
replacement.
• Remove the electrolytic cell for
inspection and clean it if necessary.
See “Maintenance”.
• Add salt. See “Salt & Pool Water
Volumes”.
• Contact Intex Service Center.
Replace the cell if needed.
• Partially drain the pool and refill
with fresh water. See “Salt & Pool
Water Volumes”.
Low
Water
Flow or
No Flow
Low Salt
Level
High Salt
Level
Yes
Yes
Yes
Yes
Yes
Yes
• The expected life expectancy of the electrolytic cell is 3,000 hours under normal
use conditions.
• When replacing the cell, only use replacement cells having a label that clearly
states that it is a replacement cell for the
Krystal Clear™ Deluxe Saltwater
System (salt in pool) Model 8110
.