(106) MODEL 638R FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2014
106A
SAVE THESE INSTRUCTIONS
English
Page 7
FILTER PUMP STATIONARY MOUNTING OPTION
There are three mounting holes located at the bottom of the filterpump base. These holes are
provided because various country’s regulations, especially in the European community, require the
filterpump to be secured to the ground or to a base in a permanent upright position.
These three holes form a triangle pattern and are 145mm from each other. The holes are
slotted with a 7mm width.
The filterpump can be mounted on a cement base or onto a wooden structure to prevent
accidental falling over. Total assembly must exceed 18kg. The drawings on the following show two
possible ways of upright mounting.
145mm
145mm
145mm
145mm
145mm
145mm
-- (3) x M6 HEXAGON HEAD BOLTS
-- (3) x M6 HEXAGON LOCK-NUTS
It is recommended that the filter cartridge be replaced at least every 2
weeks.
1.
Make sure filter pump is not operating. Disconnect line cord.
2.
To prevent water from escaping the pool, unscrew the pool inlet nozzle
(10)
and strainer grid
(11)
from the strainer connectors and insert the hat-like plugs into the strainer connectors.
3.
In a counter-clockwise motion, remove the filter housing collar
(12)
and threaded cover
(3)
.
Be careful not to lose the cover seal
(4)
.
4.
Remove filter cartridge
(5)
to clean it. The filter may be cleaned from the spray from a water
hose.
5.
Use judgement as to whether cartridge needs to be replaced.
6.
Return cartridge to filtering position.
7.
Return the seal
(4)
and threaded cover
(3)
to their original positions and in a clockwise
direction rescrew the housing collar
(12)
onto the filter housing.
8.
After service, open the air release valve, remove the plugs, allow any air to escape through
the valve before tightening the valve again and replace the pool inlet nozzle
(10)
and strainer
grid
(11)
. The pump is now primed with water again and may be turned on.
CLEANING OR REPLACING FILTER CARTRIDGES