TROUBLESHOOTING GUIDE

IMPORTANT

If you continue to experience difficulty, please contact our Consumer Service 
Department for assistance. See separate “Authorized Service Centers” sheet.

FILTER MOTOR 
FAILS TO START

FILTER DOESN’T 
CLEAN POOL

FILTER DOESN’T PUMP 
WATER OR FLOW IS 
VERY SLOW

PUMP DOESN’T WORK

TOP COVER 
LEAKING

HOSE LEAKING

AIR LOCK

•  The motor is not plugged in.
•  The GFCI/RCD circuit breaker    
 is 

tripped.

•  Motor too hot and overload  

 

  protection shut motor off.

•  Improper chlorine or pH 
 levels.
•  Filter cartridge is dirty.
• Damaged cartridge.
•  Excessively dirty pool.
•  The strainer screen is 
  restricting the water flow.

•  Clogged inlet or discharge.
•  An air leak on the intake line.
•  Scale or buildup on cartridge.
•  Excessively dirty pool.
•  Dirty filter cartridge.
•  The nozzle and strainer 
  connection are reversed.

•  Low water level.
•  Strainer screen plugged up.
•  An air leak on the intake hose.
•  Faulty motor or the impeller  

 

 is 

jammed.

•  An air lock inside the 
 cartridge 

chamber.

• O-ring missing.
•  Cover or air release valve are not 
 tight.

•  Hose clamps are not 
 well-fitted.
•  Hose o-ring dislodged when 
  connecting the hose.
• Hose broken.

•  There’s air trapped in the  

 

  pump housing and inlet hose.

  TROUBLE                                CAUSE                                           SOLUTION

•  Filter cord must be plugged into a 3 wire  

 

  outlet that is protected by a Class A  

 

  Ground Fault Circuit Interrupter, or RCD.
•  Reset circuit breaker. If circuit breaker
  trips repeatedly, your electrical system 
  may have a defect. Turn off circuit 
  breaker and call an electrician to   

 

  correct the problem.
•  Let motor cool down.

•  Adjust the chlorine and pH level. Consult
   your local swimming pool supply stores.
•  Clean or replace cartridge.
•  Check the cartridge for holes. Replace  

 

 if 

damaged.

•  Operate the filter for longer periods.
•  Clean the strainer screen at the inlet.

•  Clear any obstructions in the intake  

 

  hose by discharging it inside pool wall.
•  Tighten hose clamps, check hoses for
  damage, check pool water level.
•  Replace cartridge.  
•  Clean cartridge more often.
•  Install the nozzle at the upper position  

 

  of the pool inlet, and the strainer at the
   lower position of the pool outlet.

•  Fill pool to correct water level.
•  Clean strainer screens at pool inlet.
•  Tighten hose clamps, check hose for 
 damage.
•  Clear any sticks or leaves in the   

 

 intake 

hose.

•  Open the release valve at top of pump.

•  Remove cover & check for O-ring.
•  Tighten cover or valve (Manually).

•  Tighten or change hose clamps.
•  Put the o-ring back into the groove.
•  Replace a new hose.

•  Open air release valve, lift and lower  

 

  the inlet hose until water starts to flow  

 

  out of the air release valve, close air  

 

 release 

valve.

Содержание Krystal Clear 638G

Страница 1: ...los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilis es...

Страница 2: ...X 10 3 PANTONE 295U 06 28 2014 English Page 2 TABLE OF CONTENTS Warnings 3 Parts Reference 4 Setup Instructions 5 7 Maintenance 8 9 Pool Care and Chemicals 8 Long Term Storage 9 Troubleshooting Guide...

Страница 3: ...verify that the receptacle is protected by a GFCI RCD Use a qualified electrician to install the GFCI RCD which has a maximum rate of 30mA Do not use a portable residual current device PRCD Always unp...

Страница 4: ...er and part numbers NOTE Drawings for illustration purpose only Actual product may vary Not to scale 1 2 3 4 5 6 7 8 9 10 11 12 13 REF NO DESCRIPTION QTY SPARE PART NO 1 1 1 1 1 2 4 2 2 1 1 1 1 10460...

Страница 5: ...onnection and to the lower pump connection Make sure all the hose clamps 7 are tight 6 In a counter clockwise motion unscrew the threaded filter housing collar 13 from the filter housing Grasp and rem...

Страница 6: ...the air release valve remove the plugs allow any air to escape through the valve before tightening the valve again and replace the pool inlet nozzle 10 and strainer grid 11 The pump is now primed with...

Страница 7: ...ee holes form a triangle pattern and are 145mm from each other The holes are slotted with a 7mm width The filter pump can be mounted on a cement base or onto a wooden structure to prevent accidental f...

Страница 8: ...when filling the pool as well as during the season Consult your local swimming pool supply store for instructions The season s first filling of the pool may have brackish water requiring extra water a...

Страница 9: ...a dry place The storage s temperature should be controlled between 32 degrees Fahrenheit 0 degrees Celsius and 104 degrees Fahrenheit 40 degrees Celsius storage location 11 The original packing can be...

Страница 10: ...ken There s air trapped in the pump housing and inlet hose TROUBLE CAUSE SOLUTION Filter cord must be plugged into a 3 wire outlet that is protected by a Class A Ground Fault Circuit Interrupter or RC...

Страница 11: ...pool liner Pool liner is slippery and or has a bad odor Water turns blue brown or black when first treated with chlorine Water is cloudy or milky Level is lower than on previous day Dirt or sand on p...

Страница 12: ...Service Center will determine the validity of the claim IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE TO THE B...

Отзывы: