Intex Hydro Flow SM24101 Скачать руководство пользователя страница 2

(303PO)  MODEL SM24101 SWIMMING MACHINE  ENGLISH  7.5” X 10.3”  PANTONE 295U  02/21/2017

303

PO

    

SAVE THESE INSTRUCTIONS

English

Page 2

Warnings

..................................................................................... 

3

 

Parts Reference

.......................................................................... 

4-5

 

Product Specification

................................................................ 

6

Setup Instructions

...................................................................... 

6-13

 

Operating Instructions

............................................................... 

14-15 

Maintenance

...............................................................................  

15

Internal Parts Replacements

.....................................................

 16-17

Troubleshooting Guide

..............................................................

 18-19

Limited Warranty

......................................................................... 

20

TABLE OF CONTENTS

Operation is subject to the following two conditions: (1) this device may not cause interference, 
and (2) this device must accept any interference, including interference that may cause 
undesired operation of the device.

Changes or modifications not expressly approved by the party responsible for compliance could 
void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with the limits for Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:
•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and the receiver.
•  Connect the equipment into an outlet on a circuit different from that to which the 
  receiver is connected.
•  Consult the dealer or an experienced radio/TV technician for help.

Содержание Hydro Flow SM24101

Страница 1: ...ories or to obtain non technical assistance Visit www intexcorp com For technical assistance and missing parts call us toll free for U S and Canadian Residents 1 800 234 6839 Monday through Friday 8 3...

Страница 2: ...Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generat...

Страница 3: ...mers and other equipment To reduce the risk of electric shock replace damaged cord immediately Use a qualified electrician to replace the cord To reduce the risk of electric shock do not use extension...

Страница 4: ...Bracket NOTE Drawings for illustration purpose only Actual product may vary Not to scale REF NO DESCRIPTION QTY IGP POOL Intex Rectangular Frame Pool Intex Round Frame Pool SPARE PART NO 1 Mounting Br...

Страница 5: ...control 1 12381 12381 12381 19 Emergency stop lanyard 1 12374 12374 12374 20 Clamp knob 2 12395 12395 12395 21 Circuitry box 1 12387 12387 12387 22 Support bracket 1 12398 12398 12398 23 Support plate...

Страница 6: ...zing temperature 3 Provide adequate access space and lighting for routine maintenance 4 The transformer requires free circulation of air for cooling Swim Trainer Unit and Support Bracket Assembly for...

Страница 7: ...nting Bracket Assembly A For Intex Rectangular Frame Pools 1 Mounting Bracket Assembly see figures 1 1 to 1 2 NOTE Center the swim trainer unit on the short end side of the pool 2 Installing the mount...

Страница 8: ...acket top surface is level 3 Swim Trainer Unit Assembly see figures 3 1 to 3 2 Be sure the swim trainer unit support bracket is closed before installing the swim trainer unit onto the mounting bracket...

Страница 9: ...ure 4 3 to 4 5 For shape pipe remove the bracket space filler 3 from the mounting bracket 2 see figure 4 2 For O shape pipe go to next step Insert the bracket poles 6 into the mounting bracket 2 inner...

Страница 10: ...igure 5 2 For shape vertical leg pipe do not include the A B C gap filler 11 For 38mm diameter vertical leg pipe include A gap filler For 44mm diameter vertical leg pipe include B gap filler For 48mm...

Страница 11: ...tention to the electrical gas and water lines when drilling the holes All screws provided must be used Drill two holes on the center of the short end side of the pool edge where the mounting bracket w...

Страница 12: ...with only the top surface of the housing exposed Lock the nuts in place after the height of the swim trainer unit is adjusted see figure 7 2 Attach the display panel 16 onto the swim trainer unit moun...

Страница 13: ...away from the pool so as to prevent children from climbing on it and accessing the pool 4 Test the GFCI or RCD before use a Press the RESET button The indicator on the RCD should be ON b Press the TE...

Страница 14: ...ease or decrease the speed setting NOTE The default speed is 3 speed adjustment ranges from 1 to 8 D Speed Setting Display Once activated the system displays the swim trainer unit speed automatically...

Страница 15: ...ver Long Term Storage and Winterization You must disassemble and store the product indoors when the temperature drops below 0O C 32O F or when the appliance will not be used for a long period of time...

Страница 16: ...0 3 PANTONE 295U 02 21 2017 303 PO SAVE THESE INSTRUCTIONS English Page 16 INTERNAL PARTS REPLACEMENTS Tools required one Philip screwdriver one flat screwdriver and one small adjustable wrench A Prop...

Страница 17: ...MING MACHINE ENGLISH 7 5 X 10 3 PANTONE 295U 02 21 2017 303 PO SAVE THESE INSTRUCTIONS English Page 17 INTERNAL PARTS REPLACEMENTS continued B Swim trainer unit bracket and circuitry box disassembly 2...

Страница 18: ...al Make sure the device is under the water It s normal Turn off the transformer for 1 minute then plug in Check the voltage is within the range stated on the device housing H Household voltage is too...

Страница 19: ...e motor cool down and restart again No LED display The transformer is unplugged or off The transformer is not connected with swim trainer unit Display panel cord is loose Display panel failure Emergen...

Страница 20: ...ll disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no...

Отзывы: