manualshive.com logo in svg
background image

(307IO)  MODEL HP3220  HEAT PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  10/10/2017

English

307

IO

SAVE THESE INSTRUCTIONS

English

Page 6

PRODUCT SPECIFICATIONS

•  Pump and pool must be installed and fi lled with water prior to installation. Two adults required.
•  Tools required: one adjustable wrench, one Philip screwdriver.
•  The unit will work properly as long as the following three elements are present: 
 

1. Fresh air          2. Electricity          3. Swimming pool water

(Unit: mm)

752

485

24

260

96

131.5

270

290

560

752

*Measured Condition at 27°C Ambient Air, 27°C Water

Heat Output

4.1 kW (13,911 Btu) / hr

Power Consumption

0.78 kW (2,646 Btu) / hr

Coeffi cient of Performance (COP)

5.2

*Measured Condition at 15°C Ambient Air, 26°C Water

Heat Output

3.1 kW (10,518 Btu) / hr

Power Consumption

0.75 kW (2,544 Btu) / hr

Coeffi cient of Performance (COP)

4.1

General Data

Voltage / Frequency / Phase

220 - 240 V / 50 Hz (with in line RCD) / 1 PH

Rated current

3.5 A

Advised fuse

16 A

Recommended pool water capacity

5 - 11 m³

Required system water fl ow rate

1.8 - 10 m³/hr

Maximum water pressure (excluding bypass kit / hoses)

0.4 MPa

Water pressure drop

15 kPa

Operating water temperature range

15°C - 35°C

Operating air temperature range

8°C - 40°C

Class of protection

I

Type of protection

IPX4

Heat exchanger

Titanium inside a PVC reservoir

Compressor / refrigerant type

Rotary / R410A

Refrigerant gas quantity

0.5 kg

Inlet / outlet fi tting size

38 mm hose with collar nut

Noise level at 1 m

48 dB(A)

Fan input power

68 W

Fan speed

830 - 870 RPM

Global warming potential (GWP)

2088

CO

2

 Equivalent

0.95 T

Weight Net / Gross

33 / 40 kg

Dimension

780 x 340 x 485 mm

* Pool covered with a solar pool cover

This heat pump only has heating fuction.
Contains fl uorinated greenhouse gases. Fluorinated greenhouse gases are contained in 
hermetically sealed equipment.

Содержание HP3220

Страница 1: ...g Ltd Intex Recreation Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademark...

Страница 2: ...NSTRUCTIONS English Page 2 Warnings 3 4 Parts Reference 5 Product Specifications 6 Set Up Instructions 7 11 Display Control Panel Operation 12 13 Maintenance 14 Pool Water Chemistry 14 Heat Pump Carin...

Страница 3: ...disassembly by adults only Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Position this product away from pool to prevent a child from climbing on...

Страница 4: ...y have been given supervision or instruction concerning use of the heat pump by a person responsible for their safety The heat pump doesn t work at air temperatures below 8 C Disconnect the power cabl...

Страница 5: ...or illustration purpose only Actual product may vary Not to scale When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 L SHAPE O RING 2 11228 2...

Страница 6: ...Performance COP 4 1 General Data Voltage Frequency Phase 220 240 V 50 Hz with in line RCD 1 PH Rated current 3 5 A Advised fuse 16 A Recommended pool water capacity 5 11 m Required system water flow r...

Страница 7: ...collection containers The heat pump must be fixed and installed on a flat solid vibration free and level support cement slab or prefabricated platform Do not install the heat pump on unstable ground T...

Страница 8: ...event chemical saturated water reflux which could damage the heat pump and void the warranty The water circulation system must be arranged observing the following general layout Pool Pump Filter Heat...

Страница 9: ...Typical in ground pool arrangement Pool Filter Pump Chemical Treatment Heat Pump Power Cable Inlet Condensation Draining Pipe Water to Pool Water Pump Filter Check Valve Chemical Treatment Water from...

Страница 10: ...electrical outlet socket Initial Operation Make sure the pool is filled with water to the correct level the skimmer and suction fittings are below the water level To heat the pool water the filter pu...

Страница 11: ...s higher than 1m above or below the heat pump s automatic flow switch adjustment knob your specialist technician may need to adjust the initial startup water flow rate Refrigerant Gas Pressure Verific...

Страница 12: ...its will flash Press or to adjust the hour from 00 to 23 2 Press again and the minute MM digits will flash Press or to adjust the minute from 00 to 59 3 Press again to confirm the Clock Time Timer ON...

Страница 13: ...same time for 5 seconds The LED display will show a lock icon The button is also locked To unlock press and at the same time for 5 seconds and the lock icon will disappear Mode Setting Button For qual...

Страница 14: ...le from the main electrical outlet Or turn off the electrical power at the main circuit breaker panel 2 Shut off the water supply bypass kit to the heat pump 3 Disconnect the IN and OUT water connecti...

Страница 15: ...ne level every 2 3 days Verify pH level once a week Verify Alkalinity level every 3 4 weeks More often if you own an Automatic Chlorine or Bromine Feeder Verify Calcium Hardness once a month Above tes...

Страница 16: ...gas pressure lower Compressor failure Probable accumulation of condensation Possible water leak from the water exchanger or from hydraulic unit connection devices Follow the instructions in Initial O...

Страница 17: ...atus means the unit is electrically connected but not running Setting Step 1 Standby status Press M 5 seconds Press M again 1 27 Press to enter heating temperature setting press or to alter heating te...

Страница 18: ...f 0 1 1 Adjustable by technicians 08 Mode cooling only heat pump auxiliary electrical heating hot water 0 3 3 hot water Adjustable by technicians 09 Water pump keep running or stop after compressor st...

Страница 19: ...ature sensor connection T5 temperature sensor broken replace T5 sensor Terminal block for T5 connection on PCB broken replace PCB Water out temperature sensor broken Check T4 temperature sensor connec...

Страница 20: ...nnection on PCB broken replace PCB No water flow or low water flow Verify if water inlet and outlet hoses pipes are connected correctly Ensure pool inlet and outlet cover grid is clean and free from o...

Страница 21: ...s the necessary competence in emission prevention recovery of fluorinated greenhouse gases and safe handling of the relevant type and size of equipment covered by the certificate Record keeping Operat...

Страница 22: ...DEL HP3220 HEAT PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 10 10 2017 English 307 IO SAVE THESE INSTRUCTIONS English Page 22 SERVICE BY QUALIFIED TECHNICIANS continued Parts Diagram for qualified technician...

Страница 23: ...ANCE 22 HIGH PRESSURE PROTECTION SWITCH 6 TRANSFORMER 23 LOW PRESSURE PROTECTION SWITCH 7 FIVE POSITION TERMINAL BLOCK 24 SUCTION VALVE 8 CLIP 25 PIPE EXCHANGER TO CAPILLARY 9 ELECTRIC BOX 26 LOGO 10...

Страница 24: ...ermine the validity of the claim If the item is covered by the provisions of the warranty the item will be repaired or replaced with the same or comparable item at Intex s choice at no charge to you O...

Отзывы: