4
Switch configuration
Please, make sure that switches are placed in the right position
as per your desired settings.
Switches
1 2 3 4
Description
0 X X X
Slave - A LG Controller must be present in BYR bus, configured as Master (Default value)
1 X X X
Master – LG Controller not needed in BYR bus. If it exists, it must be configured as Slave
X 0 X X
Error Type B – Machine must be Type B (Default value)
X 1 X X
Error Type A – Machine must be Type A
X X 0 X
Low Power Mode
X X 1 X
High Performance Mode (Default value)
X X X 0
WIFI power is limited
X X X 1
Max WIFI power (Default value)
Switch 3
This switch determines the performance of the device. Running in High Performance Mode means maximum consumption
and maximum device performance.
Switch 4
This switch determines the Wi-Fi range of the device. Maximum range is set by default. Consider that changing this switch
may affect to device Wi-Fi communication, happening a device in a running installation not to reach the current access
point or Wi-Fi network to which is connected.
In case no external supply is used:
In very specific installations, AC port consumption may be overpassed, leading the
device to reboot. If that happened, decrease device consumption by using SW3 and SW4.
NOTE:
Remember that you need to power cycle the climate system or the IntesisHome device for the changes in the
switches to be applied.
1 = UP
0 = DOWN
1 = UP
0 = DOWN