WARNING
Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may
damage seriously the interface and/or the AC indoor unit.
• This interface must be installed by accredited technical personnel (electrician, installer or authorized technical personnel) and
following all the safety instructions.
• This interface must only be installed in a restricted access location.
• Before manipulate the AC indoor unit be sure it is completely disconnected from Mains power.
• In case of installation of the interface inside the AC indoor unit, fix the interface and communication cables preferably to any
appropriate point of the plastic cover of the unit taking care of no blocking free movement of mobile parts and as far as possible
from tubes containing liquids and power cables.
1. Unplug the AC system from mains electricity.
2. Connect IntesisBox device RWB connector to Fujitsu’s Indoor Unit RWB connector or Wired Remote Control (if present).
3. Connect another cable from Fujitsu’s Indoor Unit RWB to Fujitsu’s Wired Remote Control connector (if present).
4. Configure the IntesisBox switches (see below).
6. Connect the external antenna into the antenna connector.
7. Place the antenna preferably in a vertical position and pointing directly to the Wi-Fi Router or Access Point (AP).
8. Plug the Fujitsu system to mains electricity.
Binary value
b
0
…b
3
Decimal
value
Switches
1 2 3 4
Description
x0xx
0
x
x x
Fujitsu Indoor Unit Type B. (default value)
x1xx
1
x
x x
Fujitsu Indoor Unit Type A.
xxx0
0
x x x
Slave– A Fujitsu Wired Remote Controller must be present in FGL bus, configured as Master (default value).
xxx1
1
x x x
Master in FGL bus – Fujitsu Wired Remote Controller not needed in FGL bus. If existing, it must be configured as slave.
Safety instructions
Installation instructions
Switch configuration