background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

IntesisBox

®

 ASCII Server

 

KNX 

 
 

 
 
 
 
 
 
 
 
 

 

User Manual

 

r1.0 EN 

Issue date: 

03/2019 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание IntesisBox ASCII

Страница 1: ...IntesisBox ASCII Server KNX User Manual r1 0 EN Issue date 03 2019...

Страница 2: ...se agreement or nondisclosure agreement The software may be used only in accordance with the terms of those agreements No part of this publication may be reproduced stored in a retrieval system or tra...

Страница 3: ...tered trademark of Intesis Software SLU 3 20 email info intesisbox com web www intesisbox com phone 34 938047134 Gateway for the integration of KNX installations into ASCII IP or ASCII Serial enabled...

Страница 4: ...CII TCP 8 3 4 Address Map 8 3 5 Points definition 8 3 6 ASCII messages 10 4 Connections 11 4 1 Powering the device 12 4 2 Connection to ASCII 12 4 2 1 ASCII TCP IP 12 4 2 2 ASCII Serial 12 4 3 Connect...

Страница 5: ...m signals and resources from any system capable to be programmed to read and write simple text messages through EIA232 or EIA485 serial port or Ethernet TCP IP port for example Extron LiteTouch system...

Страница 6: ...ages requesting writings of points and acts according to the message received See ASCII interface section for details about this ASCII messages Each KNX group address from the KNX is associated to an...

Страница 7: ...termined by the flags configured for the point See details in section 4 2 2 Points definition Every internal datapoint to define has the following KNX properties Property Description Description Descr...

Страница 8: ...is not configured to do so then the new value will be available to be polled in any moment from the ASCII enabled device connected to this ASCII interface This behaviour of sending or not through the...

Страница 9: ...g to the communication object Function Read Write Read Write KNX communication object flags R T R T W U W U Ri U W Ri U R W Ri T U R W T U W T Spontaneous Determines if any change of value for the poi...

Страница 10: ...gateway Character use to indicate that this is a reading message configurable from the configuration tool r Carriage return character HEX 0x0D DEC 13 Message to write a point s value ASCII_String vv r...

Страница 11: ...after powering up the gateway DHCP will be enabled for 30 seconds After that time if no IP is provided by a DHCP server the default IP 192 168 100 246 will be set PortA KNX Connect the KNX TP1 bus to...

Страница 12: ...communication cable coming from the ASCII network to the port marked as Port B of IntesisBox Connect the EIA485 bus to connectors to connectors B1 B B2 A and B3 SNGD of gateway s PortB Respect the pol...

Страница 13: ...gateway Mini USB cable to connect to PC Link to download the configuration tool Product documentation 5 2 IntesisBox MAPS Configuration monitoring tool for IntesisBox ASCII series 5 2 1 Introduction...

Страница 14: ...nfigure the connection parameters Three subsets of information are shown in this window General Gateway general parameters ASCII ASCII interface configuration and KNX KNX TP 1 interface configuration...

Страница 15: ...aracter to be used to read or write the internal gateway datapoint Port TCP port to be used for the ASCII communication By default it is set to 5000 Keep Alive Time of inactivity before sending a keep...

Страница 16: ...to the IntesisBox using the Send button in the Receive Send section 5 2 6 Diagnostic To help integrators in the commissioning tasks and troubleshooting the Configuration Tool offers some specific too...

Страница 17: ...U All rights reserved IntesisBox is a registered trademark of Intesis Software SLU 17 20 email info intesisbox com web www intesisbox com phone 34 938047134 Figure 5 6 Diagnostic More information abou...

Страница 18: ...ARNING In order to avoid earth loops that can damage IntesisBox and or any other equipment connected to it we strongly recommend The use of DC power supplies floating or with the negative terminal con...

Страница 19: ...ded 24VDC Push Button Button A Reserved for future use Button B Reserved for future use Operation Temperature 0 C to 60 C Ethernet 1 x Ethernet 10 100 Mbps RJ45 2 x Ethernet LED port link and activity...

Страница 20: ...stered trademark of Intesis Software SLU 20 20 email info intesisbox com web www intesisbox com phone 34 938047134 7 Dimensions Recommended available space for its installation into a cabinet wall or...