background image

the GarageVac to secure in place.  If the vacuum cleaner is loose, you will need to tighten the 

screws further. 

8. 

The hose retainer is right side up if you can read the word “Warning” impression correctly

.  

Secure the hose retainer on the front panel of the GarageVac with the two small black screws. 

(There is a small indentation on the retainer where the screws can penetrate). 

ALWAYS CHECK TO BE SURE THE DUST BAG AND MOTOR FILTER ARE IN PLACE BEFORE 

USING! 

 

Model GF-120 and GF-220 Recessed installation into Drywall (Gypsum Wall) 

 

GROUNDING INSTRUCTIONS FOR GF-120 VOLT ONLY, WHEN PERMANENTLY WIRED

 

This appliance must be connected to a grounded metal, permanent wiring system or an equipment-

grounding conductor must be run with the circuit conductors and connected to the equipment-grounding 

terminal or lead on the appliance. 

WARNING:  Disconnect all electrical power to the wall area before installing!  Do not drill near 

studs where electrical cable may be secured to studs adjacent to receptacles. 

NOTE:  The four mounting holes in the outer corners of the flange of the power unit must be 

drilled from the back of the unit with a 3/16” (4.5mm) drill bit when the unit is to be recessed into a 

wall. 

For added stability, mount against the side of a wall stud. 

1.  Before making the cutout, ensure that no electrical switches or outlets are obstructing the area. 

2.  Tape template L-45 against the wall a minimum of 3” from the floor to allow for exhausting air. 

3.  Install 14-gauge (1.0mm) AWG, 300V minimum Romex cable (use wire cutters rated for at least 

95C) from the electrical power supply and pull the power cable through the wall cut-out. 

4.  North American Installation: Remove the side cover plate of the vacuum and pull the three inside 

wires through the opening.  Insert the 120-volt power supply cable through the Romex clamp and 

out through the side opening.  With three wire nuts, connect black to black, white to white and 

green to bare ground conductor wires.  Tighten the Romex clamp and replace the side cover.  

5.  European installation (220/230 volt). 

Does not require a ground wire

. The vacuum cleaner is 

double insulated:  Pull the two wires with the terminal block out.  Connect the power cable to the 

terminal block inside the housing.  With a pair of pliers, insert the cable with the strain relief (CE) 

and replace the side cover. 

6.  Slide the unit, bottom first, into the opening and secure with the four screws. 

7. 

The hose retainer is right side up if you can read the word “Warning” impression correctly

.  

Secure the hose retainer on the front panel of the GarageVac with the two small black screws. 

(There is a small indentation on the retainer where the screws can penetrate). 

8.  Check to be sure the dust bag and motor filter are in place. 

 

HOW TO OPERATE YOUR GARAGEVAC 

GarageVac is equipped with a thermal protector on the motor.  If your vacuum shuts off due to 

overheating, turn the switch to off and allow to cool.  It will reset after about one hour.  (See 

trouble shooting guide). 

 

A.   Connecting and disconnecting the hose. 

1.   Lift the inlet valve cover on the front of the door. 

2.  Insert hose cuff with a twist and a firm push to secure. 

3.  To remove, turn hose in either direction while pulling hose towards you. 

B.  On / Off Switch

 

1.   To start the vacuum cleaner, push the switch to the “I” position. 

2.  To stop the vacuum cleaner, push the switch to the “O” position 

C.   How to change the dust bag. (Uses 

Y-08

 single bag an

Y08-5

 replacement bags). 

1.  Open the door on the vacuum cleaner by pushing the latch upward and remove both door 

and dust bag. 

2.  To avoid spillage, carry door with dust bag attached to the trash container. Dispose of full 

bag. 

Содержание garage vac GH-120

Страница 1: ...CABINET This manual must be read and understood before installation adjustment service or maintenance is performed This unit should be installed by a qualified technician Modification of this product...

Страница 2: ...openings blocked keep free of dust lint hair and any other material that may reduce air flow If the secondary filter becomes dirty rinse in warm water or replace with a new filter Filter should be co...

Страница 3: ...ns may not apply to you This warranty gives you specific legal rights that vary from state to state If a problem with this product develops during or after the warranty period you may contact your dea...

Страница 4: ...pull the three inside wires through the opening Insert the 120 volt power supply cable through the Romex clamp and out through the side opening With three wire nuts connect black to black white to whi...

Страница 5: ...clogged hose Clear clog and allow motor to reset 2 The bag is overfilled or fine dust has clogged the bag Vacuuming large amounts of dust other than household dirt such as drywall or fine saw dust can...

Страница 6: ...tre lu et compris avant l installation le r glage l entretien ou la maintenance Cet appareil doit tre install par un technicien qualifi La modification de ce produit peut tre extr mement dangereuse e...

Страница 7: ...oussi re des peluches des cheveux et de tout autre mat riau pouvant r duire le flux d air Si le filtre secondaire devient sale rincez le l eau ti de ou remplacez le par un nouveau filtre Le filtre doi...

Страница 8: ...u la limitation des dommages accessoires ou cons cutifs ou des limitations de la dur e d une garantie implicite Les exclusions ou limitations ci dessus peuvent ne pas s appliquer vous Cette garantie v...

Страница 9: ...e la zone 2 Avec du ruban adh sif collez le gabarit L 45 contre le mur au moins 3 po 7 6 cm du sol pour permettre l vacuation de l air 3 Installez un c ble Romex AWG de calibre 14 1 0 mm 300 V minimum...

Страница 10: ...ille Vous pouvez galement nettoyer le filtre sale en passant l aspirateur ou en le lavant la main avec un savon doux Ne pas nettoyer la machine laver Laissez le filtre s cher compl tement et r utilise...

Страница 11: ......

Отзывы: