Interton RD2CIC-HP Скачать руководство пользователя страница 21

 

41

40

12 

i

 General warnings

1.  Consult a hearing care professional if you think there may be a foreign object in your ear canal, 

if you experience skin irritation, or if excessive earwax accumulates with the use of the hearing 
aid.

2.  Different types of radiation, from e.g. NMR, MRI, or CT scanners, may damage hearing aids. It is 

recommended not to wear hearing aids during these or other similar procedures. Other types 
of radiation, such as burglar alarms, room surveillance systems, radio equipment, mobile tel-
ephones, contain less energy and will not damage hearing aids. However, they have the potential 
to momentarily affect the sound quality or temporarily create undesired sounds from hearing 
aids.

3.  Do not wear hearing aids in mines, oil fields, or other explosive areas unless those areas are 

certified for hearing aid use.

4.  Do not allow others to use your hearing aids. 
5.  Hearing aid usage by children or mentally disabled persons should be supervised at all times to 

ensure their safety. The hearing aid contains small parts that could be swallowed by children. 
Please be mindful not to leave children unsupervised with this hearing aid.

6.  Hearing aids should be used only as prescribed by your hearing care professional. Incorrect use 

may result in sudden and permanent hearing loss.

7.  Warning to hearing care professionals: Special care should be exercised in selecting and fitting 

hearing aids with maximum sound pressure level that exceeds 132 dB SPL with an IEC 60711:1981 
occluded ear simulator. The remaining hearing may risk further impairment.

8.  Turn off your wireless functionality by using the flight mode in areas where radio frequency 

emission is prohibited.

9.  If a hearing aid is broken, do not use it.

11.2.2 Change Cerustop (white) wax filters

1.  To remove the old wax guard, insert the removal side of the wax guard tool into the used wax 

guard so that the shaft of the tool is touching the rim of the wax guard. Slowly pull the wax 
guard straight out.

2.  To insert the new wax guard, gently press the replacement side of the wax guard tool straight 

into the hole of the sound outlet until the outer ring lies flush with the outside of the receiver. 
Pull the tool straight out -the new wax guard will remain in place.

i

TIP

: Pressing on the new filter with the flat side of the wax filter tool can ensure that the filter is 

correctly in place.

NOTE

: If a different type of wax filter is used for your hearing aids, or if your hearing aids do not 

use wax filters, consult your hearing care professional for guidance.

i

CAUTION

: Use only original Interton consumables e.g. wax filters.

Содержание RD2CIC-HP

Страница 1: ...User guide Custom hearing aids Interton Ready...

Страница 2: ...ay on page 16 AutoPhone on page 25 Telecoil on page 27 Tinnitus Sound Generator on page 30 Hearing aid type designations for models included in this user guide are DA312i FCC ID X26DA312i IC 6941C DA3...

Страница 3: ...ring aids is a major step it is only one step in a process toward more comfortable hearing Successfully adapting to the amplification your hearing aid provides takes time and consistent use You will e...

Страница 4: ...eceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from the one in which the re ceiver is connected Consult the dea...

Страница 5: ...HP RD6ITC MP RD4ITC DW UP RD4ITC DW HP RD4ITC DW MP RD4ITC D UP RD4ITC D HP RD4ITC D MP RD4ITC W UP RD4ITC W HP RD4ITC W MP RD4ITC UP RD4ITC HP RD4ITC MP RD3ITC DW UP RD3ITC DW HP RD3ITC DW MP RD3ITC...

Страница 6: ...ions for the TSG module 30 9 2 1 Description of the device 30 9 2 2 Explanation of how the device functions 31 9 2 3 The scientific concepts that form the basis for the device 31 9 2 4 TSG volume cont...

Страница 7: ...h 3 Removal cord optional 4 Sound outlet 5 Wax filter 6 Vent 7 Microphone sound inlet s 8 Volume control optional 9 Model 10 Manufacturer 11 Serial number 6 2 Your hearing aid In the Canal RD ITC 1 Pu...

Страница 8: ...0 9 8 5 4 15 14 6 3 Your hearing aid In the Ear RD ITE 1 Push button 2 Battery door and On Off switch 3 Sound outlet 4 Wax filter 5 Vent 6 Microphone sound inlet s 7 Volume control optional 8 Model 9...

Страница 9: ...information on appro priate battery type size for your hearing aid Remove the protective foil to activate the battery On Off 3 Wait for 2 minutes before inserting the battery into the hearing aid 4 In...

Страница 10: ...l Hearing aid Remote Control Streaming Fully charged P P P Low P P O Depleted change battery P O O 7 4 Insert remove hearing aids iCAUTION Never attempt to modify the shape of the hearing aid ear moul...

Страница 11: ...l if present allows you to adjust the volume of your hearing aids to your liking 1 To increase the volume turn the volume control up 2 To decrease the volume turn the volume control down When you chan...

Страница 12: ...ase The volume changes to one hearing aid are repeated on the other side to keep the levels the same 8 Telephone use Your hearing aid allows you to use the telephone as you ordinarily do Finding the o...

Страница 13: ...ility However not all cell phones are hearing aid compatible HAC Any degree of disturbance can be due to the nature of your particular cellular phone or of your wireless telephone service provider i N...

Страница 14: ...for reliable AutoPhone activation and good hearing on the telephone NOTE If your hearing aids have enabled the Comfort Phone functionality the hearing aid on the non phone ear automatically turns dow...

Страница 15: ...not hold the handset too tightly against your ear 8 6 Flight mode optional iWARNING When boarding a flight or entering an area where RF transmitters are prohibited deactivate wireless functionality Yo...

Страница 16: ...ring from tinnitus 9 2 2 Explanation of how the device functions The TSG module is a frequency and amplitude shaped white noise generator Noise signal level and fre quency characteristics can be adjus...

Страница 17: ...professional can also enable environmental monitoring synchronization so that the TSG noise level is automatically adjusted simultaneously in both hearing aids dependent on the background sound level...

Страница 18: ...rdian supervision while wear ing the TSG hearing aid 9 3 3 iPrescription use of a Tinnitus Sound Generator hearing aid The TSG module should be used as prescribed by your doctor audiologist or hearing...

Страница 19: ...wearing them 9 4 2 iTinnitus Sound Generator warning to hearing care professionals A hearing care professional should advise a prospective sound generator user to consult promptly with a licensed phy...

Страница 20: ...perspiration the use of a drying kit is recommended 11 2 Replacing wax filters Custom hearing aids may have wax filters that protect against wax and moisture It is recommended that these are changed...

Страница 21: ...our hearing care professional Incorrect use may result in sudden and permanent hearing loss 7 Warning to hearing care professionals Special care should be exercised in selecting and fitting hearing ai...

Страница 22: ...affected In that case move the hearing aid away from the affected electronic device 2 When using wireless functionality and the devices are affected by electromagnetic interference move away from the...

Страница 23: ...Y LEAK OR EXPLODE WARNING ZINC AIR BATTERIES CAN BE HARMFUL TO YOUR HEALTH CONSULT A PHYSICIAN IMMEDIATELY IF A BATTERY HAS BEEN SWALLOWED DO NOT PLACE ZINC AIR BATTERIES IN YOUR MOUTH KEEP BATTERIES...

Страница 24: ...iew of any other available information concerning the prospective user that the prospective user has any of the following conditions 1 Visible congenital or traumatic deformity of the ear 2 History of...

Страница 25: ...itions that may affect hearing are identified and treated before the hearing aid is purchased Following the medical evaluation the physician will give you a written statement that states that your hea...

Страница 26: ...ing an object e g a hat a telephone receiver close to a hearing aid Move your hand away to create more space between the hearing aid and the object Is your ear full of wax Visit your physician No soun...

Страница 27: ...ery dirty Clean it or replace it with a new one Did your hearing aid get moist Use a desiccant Battery drains very quickly Did you leave your hearing aid switched on for long periods of time Always sw...

Страница 28: ...assistance Interton hearing aids that malfunction must be repaired by a qualified technician Do not attempt to open the case of hearing aids as this will invalidate the warranty 23 Temperature test tr...

Страница 29: ...t Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer Redistributions in binary form must reproduce the above copyright notice th...

Страница 30: ...59 58...

Страница 31: ...td Kirtlington Business Centre Portway Kirtlington Oxon OX5 3JA Tel 44 1869 352 800 interton com Australia GN Hearing Australia Pty Ltd Gate C 19 25 Khartoum Road Macquarie Technology Park Macquarie P...

Отзывы: