Intertherm DESIGNER 36 Скачать руководство пользователя страница 10

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

10

Roof Ridge

120

°

Step 10. Using a FBTM Termination:

1.

 Hold the FBTM over top of last chimney

section (

Figure 30 ).

2.

 Center inner slip section in inner flue pipe-

slip down.

Figure 29

Figure 30

Figure 31

3.

 Center outer locking section over outer flue

pipe. Push down until locking tabs are firmly
engaged.

4.

 Pull up slightly on FBTM to ensure locking

joint has firmly engaged.

Note:

 It is recommended that all exterior ex-

posed metal fireplace components; such as
terminations, flashings, storm collars and/or
flue be painted with a premium quality, high
temperature, rust preventative paint designed
for metal. This is especially important when
installations are made in abnormally adverse or
corrosive environments; such as near lakes,
oceans or in areas with consistently high hu-
midity conditions. Consult the paint manufac-
turers instructions for proper preparation and
application.

TEN FOOT RULE SUMMARY

The minimum chimney height above the roof
and/or to adjacent walls and buildings is speci-
fied by all major building codes.

If the horizontal distance from the peak of the
roof is less then 10', the top of the chimney
must be at least 2' above the peak of the roof.

If the horizontal distance from the chimney
edge to the peak of the roof is more than 10' a
chimney height reference point is established
on the roof surface 10' horizontally from the
chimney edge.  The top of the chimney must be
at least 2' above this reference point. In all
cases, the chimney cannot be less then 3'
above the roof at the edge of the chimney.

The 2' in 10' rule is necessary in the interest of
safety but does not ensure smoke-free opera-
tion. Trees, buildings, adjoining roof lines,
adverse wind conditions, etc., may require a
taller chimney should the fireplace not draft
properly (

Figure 31 ).

Less Than 10'

3'

Min

2' Min.

10'

3'

Min

Locking Band

Mastic

Or Roof

Caulking

FBTM

Termination

Chimney

Figure 27

Step 8.

 The standard FireCraft Technologies'

FTF8 roof flashing assemblies include a storm
collar. Slide the storm collar over outer chim-
ney, rest on flashing spacers and align with top
surface of flashing. Insert tab in slot, pull tight
and bend tab back over slot. Seal storm collar
to outer chimney with roof caulking or mastic
around entire circumference of pipe. Also add
extra roof caulking to the tab/slot area to seal
completely against water penetration (

Figure

28 ). Check all joints very carefully to ensure
no water intrusion can take place.

Figure 28

Note:

 If chimney extends more than 8' above

roof surface, guy wires are also recommended.
Use three (3) guy wires, attach to locking band
assembly, extend and secure to roof in a
triangular pattern (Figure 29 ). Guy wires are
not supplied by the manufacturer.

Step 9.  

FTF locking bands, Model FLB, may be

required if the chimney extends too high above
the roof flashing. As a general rule, if the
chimney extends more than 6' above the roof
flashing, the use of locking bands is advisable
to strengthen the chimney assembly.  Align
the locking band at the chimney joint. Locking
bands wrap around pipe joints equally cover-
ing the joints of both pipe sections. Use the nut
provided and TIGHTEN snugly. Do not over-
tighten as this might damage the chimney
section (

refer to Figure 23 ).

Step 7.

 Secure flashing by nailing along the

perimeter into roof using 8d nails or equivalent
fasteners. If shingled roof, slide upper end and
sides of roof flashing under shingles (trim if
necessary), seal the top and both sides of the
flashing to the roof with roof caulking. Cover
fastener heads with roof caulking (

Figure 27 ).

Содержание DESIGNER 36

Страница 1: ...g your installation Do not alter or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chi...

Страница 2: ...a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your distributor 16 For...

Страница 3: ...lace systems are designed for in stallation in accordance with the National Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 andinaccordancewithcodessuchasth...

Страница 4: ...MBLE WARNING DONOTOBSTRUCTTHECOL LAR OPENINGS AROUND THE BASE OF THE CHIMNEY AT THE TOP OF THE FIRE PLACE NEVER USE BLOWN INSULA TIONTOFILLTHECHIMNEYENCLOSURE LOCATION OF FIREPLACE Carefully select th...

Страница 5: ...tal safety strips beneath the fireplace as illustrated Figures5 6 and 7 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests o...

Страница 6: ...wall must always be measured from a finished surface If a wall covering such as drywall is to be attached to the rear wall then the 21 552 mm must be measured from the drywall surface It is important...

Страница 7: ...1 2 dry wall at the fireplace face Ifsheathingthechaseorfinish ing with other thickness materials calculations will need to be made Perpendicular to roof ridge A B Ceiling Framing C D Roof Framing FR...

Страница 8: ...h floor brackets used to secure the fireplace to the floor to prevent shifting in transit Screw 8d Nail Or Equivalent Fastener Ensurethethimblepenetratestheroofopening The thimble must extend complete...

Страница 9: ...flue pipe and locking outer stabilizer section into place over the outer chimney pipe Position for proper clearance through framed opening and nail straps securely under tension in shear into place on...

Страница 10: ...gs adjoining roof lines adverse wind conditions etc may require a taller chimney should the fireplace not draft properly Figure 31 Less Than 10 3 Min 2 Min 10 3 Min Locking Band Mastic Or Roof Caulkin...

Страница 11: ...be used between but do not exceed 20 in total length between elbows If sections of pipe exceed 10 between elbows a chimney stabilizer must be used at the midpoint see Figure 33 The stabilizer support...

Страница 12: ...mber Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12 18 36 48 MM M Height Of Number Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12...

Страница 13: ...0 0 718 1467 29 59 1 0 0 1 1 0 743 1505 31 63 1 0 2 0 1 0 794 1600 32 64 1 0 1 0 0 1 819 1638 34 68 1 0 1 1 1 0 870 1734 35 69 1 0 0 1 0 1 895 1772 37 73 1 0 0 2 1 0 946 1861 38 75 1 0 0 0 2 0 972 190...

Страница 14: ...ow FTF8 30 Offset Elbow B A Part of Offset Return Package Model FTF8 ES30 INSTALLING OFFSETS First review the Offset Elevation Chart and Figure 37 for reference Step 1 Determine the offset distance wh...

Страница 15: ...valve key for safety Always plumb gas line installation per local codes Check all connections with soap suds leaks will bubble Never test any gas line connection with a match or open flame CAUTION WHE...

Страница 16: ...12 of the fireplace opening see Figure 46 Use a 24 W x 30 H wall shield constructed of millboard or a durable noncombustible material having an equal or greater insulating value than K 54BTU IN FT2 HR...

Страница 17: ...th exten sion to a level of 5 or more above the floor surface What combination of noncombustible materials can be used to accomplish this If common brick is used so that the 3 dimension is the height...

Страница 18: ...facing and wall surrounds to prevent air intrusion Use non combustible caulking material only to seal the black metal facing to the surround material on the finished wall Combustible materials may pro...

Страница 19: ...Storm Collar 63L59 FSC Locking Band 63L60 FLB Stabilizer 63L25 FTF8 S4 Round Termination 63L42 FTF8 CTD Adjustable Firestop Thimble HO326 FM8 AT2 Thimble Extension 2 19M52 F8 TE26 2 INSTALLATION COMP...

Страница 20: ...V D 04 2002 LHP 1110 West Taft Avenue Orange CA 92865 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue c...

Отзывы: