QN HD CCU Instruction & Admin Manual
Page 25 of 32
InterT
est, Inc. • 303 Route 94 • Columbia, NJ 07832
+1 (908) 496-
8008 •
Released 7-16-20 Admin Version
Command
Inquiry Hex
Reply HEX
Definition
Read P Version 43 09 E0 00 00 00 00 FF 43 09 EE 00 00 qr st FF
Returns PIC Version qr st in
hex. LCD shows in decimal.
Read E Version 43 09 E1 00 00 00 00 FF 43 09 EE 00 00 qr st FF
Returns EM Version qr st in
hex. LCD shows in decimal.
Shutter Table:
The shutter increment and decrement functions have 18 total steps as seen in the following table. The
shutter value can be set to any value between 1/1 to 1/20000 using the direct command. If the shutter
value is set to a different value than one in the table, the increment and decrement commands will set
the shutter value to the next highest or next lowest shutter step respectively. If the shutter is given a
decrement command while at shutter value 1/1 the shutter value will go into auto mode.
Step #
Shutter Speed
qr st value
0
Auto
00 00
1
1
00 01
2
1/2
00 02
3
1/3
00 03
4
1/4
00 04
5
1/8
00 08
6
1/15
00 0F
7
1/25
00 19
8
1/30
00 1E
9
1/50
00 32
10
1/60
00 3C
11
1/100
00 64
12
1/250
00 FA
13
1/500
01 F4
14
1/1000
03 E8
15
1/5000
13 88
16
1/10000
27 10
17
1/20000
4E 20