background image

4

Jøtul C 

550

 CB Rockland    139656_02     10/2/14

Standards

Tested and listed by Intertek Testing Services,   

Middleton, Wisconsin.
Tested to U.S. Standard ANSI/UL 1482-2011 Solid-

Fuel Type Room Heaters and Canadian Standard for 

Space Heaters for use with Solid Fuels, CAN/ULC-

S627 M93-2000.

Manufactured and distributed by:  

Jøtul North America 

55 Hutcherson Dr. 

Gorham, ME 04036 

 

This heater meets the U.S. Environment Protection 

Agency’s Phase II emissions limits for wood heaters 

manufactured and sold after July 1, 1990.

 

This appliance is not approved for use in 

mobile homes.
This appliance is listed to burn wood only. 

Do not burn other fuels.
Read this manual before you install and 

use your fireplace insert. 

 

Save these instructions and make them 

available to anyone using or servicing the 

fireplace insert.

Installation and Operation Instructions for USA/Canada

Installation et fonctionnement pour Canada

SAFETY NOTICE: IF THIS SOLID FUEL ROOM HEATER IS NOT PROPERLY INSTALLED, A 

HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIREC-

TIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND 

INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. SAVE THESE INSTRUC-

TIONS FOR FUTURE REFERENCE.

Avis de sécurité: Une installation non appropriée de ce poêle de chauffage ris-

que de provoquer un incendie. Assurez votre sécurité en respectant les directives 

d’installation suivantes. Consultez les autorités locales du bâtiment ou de la pré-

vention des incendies au sujet des restrictions et exigences relatives aux inspections 

d’installations dans votre région.

Check Building Codes

When installing, operating and maintaining your 

Jøtul C 

550

 CB Fireplace Insert, follow the guide-

lines presented in these instructions, and make 

them available to anyone using or servicing the 

stove.
Your city, town, county or province may require a 

building permit to install a solid fuel burning appli-

ance. 

In the U.S.,

 guidelines established by UL 1777, the 

National Fire Protection Association’s Code, NFPA 

211, Standards for Chimneys, Fireplaces, Vents and 

Solid Fuel Burning Appliances, or similar regula-

tions, may apply to the installation of a solid fuel 

burning appliance in your area. For further informa-

tion on using your heater safely, obtain a copy of 

the NFPA publication “Using Coal and Wood Stoves 

Safely,” NFPA No. HS-8-1974, available from NFPA 

470 Atlantic Ave. 

Boston, MA 02210.

In Canada,

 the guidelines are established by ULC-

S635, and the CSA Standard, CAN/CSA-B365-M93, 

Installation Code for Solid-Fuel-Burning Appliances 

and Equipment.  
Always consult your local building inspector or 

authority having jurisdiction to determine what 

regulations apply in your area.

 

  

Содержание Jotul C 550 CB Rockland

Страница 1: ...land 139656_02 10 2 14 J tul C 550 CB Rockland Fireplace Insert Keep these instructions for future reference Installation and Operating Instructions for the United States Canada V2 J tul C 550 CB Rock...

Страница 2: ...6_02 10 2 14 NOTICE YOU SHOULD CONSULT THE AUTHORITY HAVING JURISDICTION IN YOUR LOCALE SUCH AS MUNICIPAL BUILDING DEPARTMENT FIRE DEPARTMENT FIRE PREVENTIOIN BUREAU ETC BEFORE INSTALLATION TO DETERMI...

Страница 3: ...ntents Standards and Safety Notices Standards Codes 4 Safety Notices 5 Preparation 5 Unpacking the Firebox 5 Specifications J tul C 550 Rockland Fireplace Insert 6 Installation Masonry Fireplace Requi...

Страница 4: ...tallation non appropri e de ce po le de chauffage ris que de provoquer un incendie Assurez votre s curit en respectant les directives d installation suivantes Consultez les autorit s locales du b time...

Страница 5: ...ed appliance will not guarantee proper chimney performance Consult your local J tul authorized dealer regarding spe cific installation performance issues Installation Preparation We strongly urge you...

Страница 6: ...550 CB Rockland Fireplace Insert meets U S EPA emission limits for wood heaters sold after July 1990 and is tested and listed to ANSI UL 1482 and CAN ULC S628 93 It is intended for installation in acc...

Страница 7: ...fireplace with the following conditions The factory built fireplace must be listed per UL 127 or ULC S610 The factory built chimney system must be fully lined with listed chimney liner meeting type H...

Страница 8: ...ossible in these instances A custom built surround panel system may be used provided it does not interfere with air circulation through the convection chamber louvers Air flow within and around the fa...

Страница 9: ...such as drapes or doors that could swing into the area within 36 of the insert Mantel Clearances The installation must conform to the minimum mantel clearances specified in the chart below These clear...

Страница 10: ...line as noted below A Hearth Protection width from centerline 18 1 2 470 mm B Hearth Protection forward from door opening US 16 CAN 20 508 mm C To Side Trim 1 max thickness from centerline 21 3 4 552...

Страница 11: ...nto the first flue tile is acceptable provided the tile is no larger than 8 x 12 5 For external chimneys one or more sides are exposed to the outside below the roof line including garages a positive c...

Страница 12: ...nts from the fireplace Alternatively you can wire the damper plate to lock it in the open position Thoroughly clean the firebox and smokeshelf area with a wire brush 2 If the fireplace has been modifi...

Страница 13: ...IREPLACE 2 Insert the AC power receptacle lead through the ap propriate inlet in the side of the firebox See fig 10 Remove the 8 x 5 8 phillips screw already in place and engage the receptacle bracket...

Страница 14: ...h 5 If appropriate attach the Extended Surround Pan el to the firebox See illustration on page 6 With the painted side facing out engage the hooked tabs on panel with the slots in the backside of the...

Страница 15: ...arting or reviving the fire the control lever should be set at the far right position to allow the maximum amount of air into the stove See fig 15 After the fire is well established the lever should b...

Страница 16: ...rol without waiting for the fire to be reestablished Creosote Formation This appliance is designed to burn wood cleanly and efficiently when operated as described in this manual However when wood is b...

Страница 17: ...tion of creosote An exterior chimney whether masonry or prefabricated steel will be ex posed to cold outside temperatures and consequently will be more prone to creosote accumulation than an interior...

Страница 18: ...tible materials pending final dis posal If the ashes are disposed of by burial in soil or otherwise dispersed they should be kept in the closed container until all coals and cinders have thoroughly co...

Страница 19: ...for seal integrity The gaskets should be soft enough to be somewhat resilient to the touch Over time gaskets will com press and harden Replace worn out or hardened gaskets with the appropriate size ma...

Страница 20: ...SA 24 127215 Blower Maintenance In order to ensure that the blower delivers many years of reliable performance you should inspect it regularly and clean it of any household dust and debris that may ha...

Страница 21: ...21 J tul C 550 CB Rockland 139656_02 10 2 14 This page is intentionally blank...

Страница 22: ...ine J tul replacement parts Do not substitute parts from any other manufacturer See your local Authorized J tul Dealer or contact us directly J tul North America 55 Hutcherson Dr Gorham Maine 04038 Fi...

Страница 23: ...No Description Part Number 1 Rear Shroud 222027 2 Screw 8 x 1 2 Hex Slt 117917 3 Nut M6 Flange 117968 4 Right Baffle Plate 157045 5 Left Baffle Plate 157044 6 Secondary Air Tube Front 223262 7 Seconda...

Страница 24: ...31 Total R R brick R mineral board 0 8 0 431 1 231 Step 3 Compare proposed system R 1 231 to specified R of 0 893 Since R is greater than required the system is acceptable Definitions Thermal conducta...

Страница 25: ...red Over firing can also be identified by warped plates rust colored cast iron paint pig ment that has turned dusty white or bubbling cracking and discolor ation of the enamel finish Misuse includes w...

Страница 26: ...26 J tul C 550 CB Rockland 139656_02 10 2 14 This page is intentionally blank...

Страница 27: ...27 J tul C 550 CB Rockland 139656_02 10 2 14 This page is intentionally blank...

Страница 28: ...lations It is important that the these instructions be carefully read and understood before beginning the instal lation J tul pursues a policy of continual product development Consequently products ma...

Отзывы: