Operating Instructions CP MEGATHERM DN.A HI
Page 4 / 7
HOM177695627Ien-6
INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany ·
+49 9445 9532-0 · [email protected]
Piece
Name
4
M 6x45 cheese-head screws with hex socket
If one of the components listed here is not included in
the scope of delivery, then please contact the
manufacturer.
6
Technical Data
Protection class
IP66/IP68 1bar/30min
Rated voltage
max. 250 V AC
Permitted operating voltage
max. 275 V AC
Rated current (in
compliance with VDE 0298)
max. 10 A
Ambient temperature
- 60 to + 60°C
Max. permitted operating
temperature
- 60 to + 180°C
Switching capacity of fault
alarm (AM)
10 A / 275 V AC
Connecting cable
Silicone hose cable,
notch- and oil resistant, 3
x 1,5 mm² Ø8,8 mm
Connecting cable AM
Silicone hose cable,
notch- and oil resistant, 5
x 1,0 mm² Ø8,5 mm
Material
Seawater-proof
aluminium, black
anodized
Mean Time Before Failure
50.000 h
Storage temperature
- 60 to + 80°C
Connecting cable HI
Silicone hose cable,
notch- and oil resistant, 2
x 0,62 mm² and 3 x 1,35
mm², Ø10,2 mm
Special voltages with corresponding power adjustment
and component selection are possible.
Profile type "P" Height x
Width x Depth
225 x 229 x 60
mm
Profile type "T" Height x
Width x Depth
325 x 229 x 60
mm
INFO
You will find the precise technical data for your
instrument on the label.
Rated voltage/Operating voltage
High temperature version
Rated output
Illustration 1:
Example: CP MEGATHERM DNPA 200 HI label
7
Installation
WARNING
The heater is only designed for non hazardous
areas.
INTERTEC-Hess GmbH accepts no liability for improper
use.
NOTICE
Carefully remove
When removing from the packaging and during
transport, the connection line must not be stressed or
bent.
For free convection, the heater needs to be installed with
ribs standing vertically. The minimum distances to the
floor and to devices above it must be complied with. The
label needs to remain legible.
For the operation of the device, it is absolutely
necessary to connect an external digital temperature
controller TC… in series with the heater. The controller
housing may only be mounted at a place where 80°C is
not exceeded. See separate operating instructions for
series digital temperature controller TC.
To ensure operational safety, the heater must operate
under temperature conditions which will NOT exceed the
trigger temperature of the limiter.
The operating temperatures must be adhered to.
The connection cable must be permanently installed up
to the inlet into the on-site junction box, taking the
permissible bending radius = 5 x outer diameter into
consideration.