Bill of Materials

ITEM

QTY

DESCRIPTION

DESIGNATOR

MFR

MFR PART #

COMMENTS

COMPONENTS COMMON TO ALL BOARDS

1

1

PCB

PCB

-

ISL9000EV2 REVB

2

2

CAP, SMD, 0603, 0.01µF, 50V, 10%, X7R, ROHS C3, C4

AVX

06035C103KAT2A

0603 capacitor

3

1

CAP, SMD, 0805, 1µF, 16V, 10%, X5R, ROHS

C2

Panasonic

ECJ-2FB1C105K

0805 capacitor

4

2

CAP, SMD, 1206, 1µF, 25V, 10%, X7R, ROHS

C5, C6

Panasonic

ECJ-3YB1E105K

1206 or 1210 
capacitor

5

2

RES, SMD, 0603, 100k

, 1/10W, 1%, ROHS

R1, R2

Panasonic

ERJ-3EKF1003V

0603 resistor

6

1

CAP-TANTALUM, SMD, 100µF, 16V, 20%, ROHS C1

KEMET

T491D107M016AS

7

4

CON1

J1, J5, J7, J16

Keystone

5010

8

3

CON1

J6, J8, J15

Keystone

5016

9

1

CON2

J2

Molex

22-23-2021

10

1

CON5

J13

Molex

22-23-2051

11

1

JMP2

J10

Molex

22-28-4020

12

2

JMP4

J3, J4

Molex

22-28-4040

13

3

Shunt

AMP

382811-8

Only 3 needed 
per board 

COMPONENTS SPECIFIC TO EACH BOARD VARIATION

14

1

ISL9000A

U1

Intersil

ISL9000AIR_ _Z

15

1

Label

L1

COMPONENTS OPTIONAL ON EACH BOARD

16

2

SCOPE JACK

J11, J12

Tektronix

131-5031-00

Not populated

17

3

BANANA

B1, B2, B3

Keystone

7006

Not populated

18

2

BANANA

B4, B5

Keystone

7007

Not populated

19

1

JMP2

J9

Molex

22-28-4020

Not populated

20

1

CON6

J14

HRS

DF11-6DS-2DSA

Not populated

21

1

HEADER 8X2

JP1

Molex

10-88-1161

Not populated

Содержание ISL9000A

Страница 1: ... ENx and HI on J3 or J4 In this case the shunt between ENx and LOW is not needed If an external enable signal that drives both high and low is used to enable the LDO outputs both shunts can be removed from ENx A jumper J10 connects the CPOR input to a 10nF capacitor for POR timing The jumper can be removed and replaced by a different capacitor to ground for different power on timing requirements T...

Страница 2: ...cks but at higher currents these won t reflect the output voltage as accurately as the kelvin connections Connect the negative leads to GND J13 3 To get the best representation of the IC output voltage under all output loading conditions add a ground terminal to the GNDk pad and connect the meter ground leads there Step 5 Connect a third voltmeter to the input This can be connected to the J2 termi...

Страница 3: ...1uF J11 SCOPE JACK J12 SCOPE JACK B2 B3 1 2 J2 CON2 J10 JMP2 J9 JMP2 C4 0 01uF 1 2 3 4 5 6 J14 CON6 1 J6 CON1 1 J8 CON1 1 J5 CON1 J4 JMP4 J3 JMP4 GND 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 JP1 HEADER 8X2 1 J1 CON1 1 J7 CON1 B5 C5 1uF C6 1uF 1 J15 CON1 1 J16 CON1 1 2 3 4 5 J13 CON5 VO1 Kelvin VO1 Power GND VO2 Power VO2 Kelvin FIGURE 1 ISL9000A EVALUATION BOARD REV B SCHEMATIC ...

Страница 4: ...206 1µF 25V 10 X7R ROHS C5 C6 Panasonic ECJ 3YB1E105K 1206 or 1210 capacitor 5 2 RES SMD 0603 100kΩ 1 10W 1 ROHS R1 R2 Panasonic ERJ 3EKF1003V 0603 resistor 6 1 CAP TANTALUM SMD 100µF 16V 20 ROHS C1 KEMET T491D107M016AS 7 4 CON1 J1 J5 J7 J16 Keystone 5010 8 3 CON1 J6 J8 J15 Keystone 5016 9 1 CON2 J2 Molex 22 23 2021 10 1 CON5 J13 Molex 22 23 2051 11 1 JMP2 J10 Molex 22 28 4020 12 2 JMP4 J3 J4 Mole...