User-selectable Options
Component pads are included to enable a variety of
user-selectable circuits to be added to the amplifier VREF, inputs,
outputs, and the amplifier feedback loops.
A voltage divider (
, R
6
and R
12
) can be added to
establish a power supply-tracking common mode reference
using the VREF input. The input stages (see
) have
additional resistor and/or capacitor pads that may be used to
add voltage divider networks or feedback networks for adding
input attenuation, or to establish input DC offsets through the
VREF pin. The output stages (see
) have additional
resistor and capacitor placements for loading.
NOTE: Operational amplifiers are sensitive to output capacitance
and may oscillate. In the event of oscillation, reduce output
capacitance by using shorter cables, or add a resistor in series
with the output.
FIGURE 4. INPUT STAGE (1/2)
FIGURE 5. OUTPUT STAGE (1/2)
C
1
R
5
R
3
J2
J1
R
1
R
2
R10
R
12
R
6
R
9
R
4
DNP
DNP
DN
P
OPEN
DNP
10k
100k
100k
10k
0
VREF
IN+
IN-
OUTPUT
R
26
C
6
R
28
DNP
O
PEN
OPEN
0
FROM OUTPUT
Bill of Materials
DEVICE #
DESCRIPTION
COMMENTS
C2, C4
CAP, SMD, 1206, 1µF, 50V, 10%, X7R, ROHS
Power Supply Decoupling
C3, C6
CAP, SMD, 0805, 0.1µF, 50V, 10%, X7R, ROHS
Power Supply Decoupling
C5, C7
CAP, SMD, 0603, 0.01µF, 25V, 10%, X7R, ROHS
Power Supply Decoupling
C1, C8, C9, C10, C11, C12
CAP, SMD, 0603, DNP-PLACE HOLDER, ROHS
User selectable capacitors - not populated
D1
DIODE-SCHOTTKY BARRIER, SMD, SOT-23, 3P, 40V, ROHS
Reverse Power Protection
U1
ISL70219ASEHF/PROTO, DUAL OP AMP, 10Ld. FLATPACK
R1, R2, R5, R7, R8, R9, R17, R20, R23,
R24
RESISTOR, SMD, 0603, 0.1%, MF, DNP PLACEHOLDER
User selectable resistors - not populated
R3, R19, R21, R22
RES, SMD, 0603, 0
Ω
, 1/10W,TF, ROHS
0
Ω
user selectable resistors
R11, R14
RES, SMD, 0603, 100
Ω
, 1/10W, 1%, TF, ROHS
R4, R6, R16, R18
RES, SMD, 0603, 10k
Ω
, 1/10W, 1%, TF, ROHS
Gain resistors
R10, R12, R13, R15
RES, SMD, 0603, 100k
Ω
, 1/10W, 1%, TF, ROHS
Gain resistors