Troubleshooting
In case of a fault
DANGER
Danger to life from electrocution
4
Only perform maintenance and repair work after you have switched off power.
4
Faults on electrical equipment may be rectified only by a trained electrician!
4
Immediately power down the module and ensure that it cannot be started accidentally.
4
Remove material and objects that block the conveyor.
4
Before switching it on again, ensure that no persons are at risk.
4
Properly dispose of any gear oil that has leaked. Have the motor replaced by qualified
personnel, if necessary.
Troubleshooting
Fault
Cause
Remedy
Conveying goods jam
between the side guides
Conveying goods sit on the
module at an angle
Align conveying goods parallel
to the side guide
Center of gravity of the load is
not centered
Align the center of gravity of the
load
Transport process cannot
be started and motor does
not run
Main switch and/or control
turned off
Check the switch position; turn
on main switch and/or key
switch of the control as required
Supply line damaged
Check supply line
Transport process cannot
be started and motor is
running
Module conveyor too loose
Retension module conveyor
Transport weight too high
Observe maximum weight
Transport shows jerky
movements
Foreign objects in roller area
Remove foreign objects
Conveying goods are not
being transported
Defective drum motor
Replace defective motor
Defective roller
Replace defective roller
Module conveyor brushes
against the side frame
Module conveyor adjustment is
not straight
Adjust module conveyor