18
Version 3.0 (04/2013) en
Translation of the original instructions
RollerDrive EC100 / EC110
Assembly
Warning notices for the electrical installation
The electrical installation may only be executed by qualified and authorized
persons.
Disconnect the power before installing, removing or rewiring the RollerDrive.
Do not apply AC current to the RollerDrive or DriveControl device at any time,
as this will cause irreparable damage.
Do not apply too much tension and pressure stress to the motor connector.
Bending the cable and forcing the star washer over the cable can cause
damage to the insulation of the cable, which could result in failure of the
RollerDrive.
Ensure that the RollerDrive, the DriveControl and the 24 VDC power source
are properly earthed through the frame or supporting structure in which the
RollerDrive and the DriveControl are installed. Incorrect earthing can result in
the buildup of static charge, which can cause the motor or DriveControl to
malfunction or fail prematurely.
Do not bend the motor cable at the motor shaft. Leave a minimum of 12 mm
(0.5 in) of excess cable for stress relief. (Maintain a bending radius of at least
five times the cable diameter.)
Do not rotate the RollerDrive manually, as this generates a voltage which
could damage the DriveControl.
Risk of damage to the motor and/or the wires of the
RollerDrive
Observe the following notices.