Version 2.5 (11/2020) UL
Translation of the original operating manual
19 of 140
Product information
3.5
Technical specifications
Rated voltage for logic and sensors (L1)
24 V DC, protected extra-low
voltage (PELV)
Voltage range L1
22 to 27,5 V DC
Rated voltage for RollerDrive (L2)
24 V DC, protected extra-low
voltage (PELV)
48 V DC, protected extra-low
voltage (PELV)
Voltage range L2
22 to 27,5 V DC
44 to 56 V DC
Current consumption
Logic supply voltage L1:
MultiControl: Max. 0.2 A + connected sensors/actuators = max.
1.6 A
RollerDrive supply voltage L2:
RollerDrive rated current:
Max. 4 x 3.5 A = 14.0 A
RollerDrive starting current:
Max. 4 x 7.5 A = 30.0 A
RollerDrive rated current:
Max. 4 x 1.75 A = 7.0 A
RollerDrive starting current:
Max. 4 x 3.8 A = 15.2 A
Protection rate
IP54 (not UL-tested)
Degree of contamination
2
Weight
500 g (incl. base plate)
Ambient temperature in operation
-30 °C to +40 °C (-22 °F to +104 °F)
Ambient temperature during transport and
storage
-40 °C to +80 °C (-40 °F to +176 °F)
Max. temperature change
1 K/min, 3 h, 2 cycles
Max. relative humidity
93% at +40 °C (104 °F), 14 days, non-condensating
Altitude of installation site
Max. 1000 m (3280 ft)
In principle, it is possible to install the equipment at altitudes
higher than 1000 m (3280 ft). However, this may reduce the
performance values.
Содержание MultiControl AI
Страница 68: ...68 of 140 Version 2 5 11 2020 UL Translation of the original operating manual Appendix ...
Страница 74: ...74 sur 140 Version 2 5 11 2020 UL Traduction de la notice d utilisation originale ...
Страница 136: ...136 sur 140 Version 2 5 11 2020 UL Traduction de la notice d utilisation originale Annexe ...
Страница 137: ...Version 2 5 11 2020 UL Traduction de la notice d utilisation originale 137 sur 140 Notes ...
Страница 138: ...138 sur 140 Version 2 5 11 2020 UL Traduction de la notice d utilisation originale Notes ...
Страница 139: ......
Страница 140: ...INSPIREDBY EFFICIENCY 2020 INTERROLL EN FR UL 11 2020 Version 2 5 1119087 ...