6.8 Adjustment for first use
Before using the machine for the first time, the following adjustments need to be made:
1. Adjustment of the milking vacuum acting on the control valve (typically for milk transport systems, set
to 50kPa
– 14.76 “Hg)
2. Cut the rope to the correct length for the milking system
NOTE
The cylinder rope is left at a length of 2.7m (8.85 ft) to allow it to be shortened
3. Adjust the distance between the hook and ball to prevent the cluster from touching the ground or the
Portable iMilk401 from being too tight during milking
If the cluster touches the ground during removal
If the cluster is too tight
CAUTION
It is forbidden to change the position of the lock ball. Distance adjustment must be made by
changing the position of the hook
4. Adjust the panel parameters. The main parameters to adjust for correct milking are:
o
Detachment delay (Par 34): reduce the parameter value in order to prevent the cluster from
falling to the ground during detachment operations. Increase the parameter value in cases
where it appears that the cluster is torn from the animal's teats.
o
Flow level for detachment (Par 17): determines the milking flow that passes on to the
DETACHMENT phase
Hook