6 MACHINE SPECIFICATIONS
6.1 Power Requirements
Electrical:
115VAC, 60HZ, 1ph, 5.0A
Standard Electrical equipment:
•
Two (2) 1/4 HP gear motors.
•
One ½ HP motor
•
A neoprene power cord.
•
A grounded plug.
Pneumatic:
10 CFM @ 90 PSI
Contact your distributor for power requirements or other information not listed above.
6.2 Specifications
Throughput Speed - Up to 12 CPM.
Hopper Capacity - Up to 75 cases (2000 lb. test)
Machine Weight - 1,675 lbs.
Discharge Height - 24” – 28”
Operating Conditions – Use in a dry, relatively clean environment at 40º to 105º F (5º to
40º C) with clean dry cartons.
Operating Range – 23” x 16” x 22” Max
10” x 7” x 4” Min
Changeover Information – 7 Operations (5-10 minutes max) No tools, no change parts