background image

Specifications

10

7

Applications for Titan’s Use

Adult Day Care Centers & Nursing Homes
Air Conditioning Contractors
Apartment Complexes
Auto Dealerships
Auto Detailers
Automobile Rentals
Beauty Parlors & Nail Salons
Bowling Alleys
Bus Lines
Business Opportunity
Businesses
Carpet Cleaners & Installers
Chemical Supply
Child Care Centers
Cocktail Lounges & Bars
Condominium Associations
Country / Golf Clubs
Cruise Ships
Doctors, Dentist & Chiropractors and Medical Clinics
Dry Cleaners
Duct Cleaning Companies
Equipment Rental Companies
Fire & Water Damage Restoration
Florists
Funeral Homes
Garbage/Dumpsters Rooms
Grocery Stores, Meat Markets and Fish & Seafood Markets
Health Clubs & Gyms
Home Owners
Hotels
Insurance Companies
Janitorial Companies
Janitorial Supply
Karate Studios
Limousine Services
Marinas / Boats
Motorhome / Recreational Vehicle Rentals
Movie Theaters
Painting Contractors
Pest Control Companies
Police Departments
Pool Supply Companies
Print Shops
Public Rest Rooms
Realtors
Restaurants
Schools
Sick Building Syndrome
Trucking Companies
Vegetable & Fruit Preservation
Warehouse / Storage Facilities

Model

#2000

#4000

Size

12" x 12" x 16"

26" x 26" x 12"

Weight

20 lbs.

38.5 lbs.

Process

UVA/Titanium Dioxide

Based Photo Catalytic

Oxidation

UVA/Titanium Dioxide

Based Photo Catalytic

Oxidation

Filtration

10" x 10" x 1/2"

Permanent Washable

Electrostatic Filter

20" x 20" x 1/2"

Permanent Washable

Electrostatic Filter

Air Movement

900 CFM Max.

5000 CFM Max.

Max. Treatment

Area

20,000 Cu. Ft.

40,000 Cu. Ft.

Volts / Amps

110 / 2

110 / 4

Hertz

50 / 60

50 / 60

Case Material

Anodized Aluminum

.060 / 14 Gauge

Anodized Aluminum

.060 / 14 Gauge

Finish

Industrial Powder Coat Industrial Powder Coat

Warranty

One Year Parts & Labor One Year Parts & Labor

Содержание Titan 4000

Страница 1: ...Titan 2000 4000 OPERATIONS MANUAL International Ozone Technologies Group Inc Delray Beach Florida USA 2015 Manufactures Of Environmental Products That Solve Problems ...

Страница 2: ...elow for future reference for warranty or insurance purposes Product Name Titan Hydroxyl Generator Model Number _________________________ Serial Number _________________________ Purchase Date _________________________ Glossary Bacteria Disease causing microscopic organism BOD Biological Oxygen Demand CFM Cubic Feet Per Minute COD Chemical Oxygen Demand Corona Arcing halo around an electrical disch...

Страница 3: ...s which vary from state to state Some states do not allow limitations on implied warranties and or do not allow the exclusion of incidental or consequential damages so the above limitations and exclusions may not apply to you Sales outside the U S A For products sold outside of the U S A contact your dealer for warranty information and Titan Titan service 16 1 S p ace Age Techn olog y S p ace Age ...

Страница 4: ...val or installation of the product e Causes external to the product such as electric power fluctuations or failure f Use of supplies or parts not meeting International Ozone Technologies Group Inc specifications g Normal wear and tear h Any other cause which does not relate to a product defect I Shipping Handling to or from International Ozone Technologies Group Inc 3 Removal installation and set ...

Страница 5: ...electrical power specified on the backside of the case Do not attempt to service this product yourself as opening or removing the enclosure may expose you to dangerous voltage or other hazards Do not put foreign objects inside the equipment Do not operate equipment with a damaged cord or plug if fans fail to rotate after the equipment malfunctions or if it has been dropped or damaged in any manner...

Страница 6: ...amp environment This equipment should only be operated using a properly grounded electrical outlet International Ozone Technologies Group Inc assumes no liability for damages or injuries incurred by misuse of this equipment 4 13 Titan 4000 Is it an Air Purifier That Scrubs The Air Or An Air Scrubber That Purifies The Air ...

Страница 7: ...t people or animals in the treatment area NOTE 60 humidity is required for optimum performance NOTE 60 humidity is required for optimum performance 5 Model 2000 Model 4000 12 Views 5 000 CFM Ball Bearing Fan 4 8 Diameter High Output TiO Photocatalytic 2 UVA Lamps 20 x 20 x 1 2 Permanent Washable Electrostatic Filter 82 Efficient Rear Mounted On Off Switch 900 CFM Ball Bearing Fan 2 8 Diameter High...

Страница 8: ...s on many variables such as pollutant load temperature humidity etc Examples for 1000 cubic feet 100 Square feet with 10 foot ceilings with lite to moderate odor Titan 2000 2 Hours Titan 4000 1 Hour As stated above these are just general guidelines In some cases you will have to go longer and in other cases you will go shorter Once you have become experienced with using your Titan for odor removal...

Страница 9: ...Karate Studios Limousine Services Marinas Boats Motorhome Recreational Vehicle Rentals Movie Theaters Painting Contractors Pest Control Companies Police Departments Pool Supply Companies Print Shops Public Rest Rooms Realtors Restaurants Schools Sick Building Syndrome Trucking Companies Vegetable Fruit Preservation Warehouse Storage Facilities Model 2000 4000 Size 12 x 12 x 16 26 x 26 x 12 Weight ...

Страница 10: ... call the factory for an number and ship the unit back We will inspect and RMA diagnose the problem If the equipment only needs adjustments or cleaning to bring it back into specifications we will gladly service and re certify your equipment you only pay free of charge shipping and handling are self cleaning and will perform at Titan s Photo Catalytic Lamps their optimum for a period of 8000 hours...