background image

Contents

Important Safeguards

3

Warnings and Precautions

4

Theory of Operation

5

General Use Guidelines

6

Trouble Shooting

8

Applications

7

Maintenance

9

Specifications

10

Dimensions

11

Front & Back Views Of Your Titan

12

Purifier or Scrubber???

13

Titan Testing

14

Warranty

15

Glossary

17

LIMITED WARRANTY

Titan Hydroxyl Generators

What the warranty covers:

International Ozone Technologies Group, Inc.

warrants its products to be free from defects in material

and workmanship during the warranty period.  If a product proves to be defective in material or
workmanship during the warranty period,

will, at its

International Ozone Technologies Group, Inc.

sole option, repair or replace the product with a like product.  Replacement product or parts may include
remanufactured or refurbished parts or components.

How long the warranty is effective:

The

is warranted for one (1) years for all parts and one (1) year for all

Titan Hydroxyl Generator

labor from the date of the first consumer purchase.

Who the warranty protects:

This warranty is valid only for the first consumer purchaser.

What the warranty does not cover:

1. Any product on which the serial number has been defaced, modified or removed.

2.

Damage, deterioration or malfunction resulting from:

a.

Accident, misuse, neglect, fire, water, lightning, or other acts of nature, unauthorized product
modification, or failure to follow instructions supplied with the product.

b.

Repair or attempted repair by anyone not authorized by

International Ozone Technologies

Group, Inc.

c.

Any damage of the product due to shipment.

d.

Removal or installation of the product.

e.

Causes external to the product, such as electric power fluctuations or failure.

f.

Use of supplies or parts not meeting

International Ozone Technologies Group, Inc.

specifications.

g.

Normal wear and tear.

h.

Any other cause which does not relate to a product defect.

I

.

Shipping & Handling to or from

International Ozone Technologies Group, Inc.

3. Removal, installation, and set-up service charges.

How to get service:

1.

For information on obtaining warranty service, call

International Ozone Technologies Group,

Inc.

The customer support telephone numbers are: U.S. and Canada 1-877-406-9663. Internet

address http://www.internationalozone.com

2.

To obtain warranty service, you will be required to provide (a) the original dated sales slip, (b)

your name, (c) your address, (d) a description of the problem, and (a) the serial number of the

product. Obtain a RMA# (Returned Merchandise Authorization) from

International Ozone

Technologies Group, Inc.

3.

Take or ship the product prepaid in the original container to

International Ozone Technologies

Group, Inc.

1100 SW 10th. Street, Ste J, Delray Beach, Florida 33444.

at

Limitation of implied warranties:

THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE
DESCRIPTION CONTAINED HEREIN INCLUDING THE IMPLIED WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Exclusion of damages:

International Ozone Technologies Group, Inc.

's

LIABILITY IS LIMITED TO THE COST OF REPAIR

OR REPLACEMENT OF THE PRODUCT.

SHALL NOT

International Ozone Technologies Group, Inc.

BE LIABLE FOR:
1.

DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE PRODUCT, DAMAGES
BASED UPON INCONVENIENCE, LOSS OF USE OF THE PRODUCT, LOSS OF TIME, LOSS
OF PROFITS, LOSS OF BUSINESS OPPORTUNITY, LOSS OF GOODWILL, INTERFERENCE

15

2

Содержание Titan 1000

Страница 1: ...Titan 1000 4000 OWNER S GUIDE International Ozone Technologies Group Inc Delray Beach Florida USA 2014 Manufactures Of Environmental Products That Solve Problems ...

Страница 2: ...elow for future reference for warranty or insurance purposes Product Name Titan Hydroxyl Generator Model Number _________________________ Serial Number _________________________ Purchase Date _________________________ Glossary Bacteria Disease causing microscopic organism BOD Biological Oxygen Demand CFM Cubic Feet Per Minute COD Chemical Oxygen Demand Corona Arcing halo around an electrical disch...

Страница 3: ...s which vary from state to state Some states do not allow limitations on implied warranties and or do not allow the exclusion of incidental or consequential damages so the above limitations and exclusions may not apply to you Sales outside the U S A For products sold outside of the U S A contact your dealer for warranty information and Titan Titan service 16 1 S p ace Age Techn olog y S p ace Age ...

Страница 4: ...val or installation of the product e Causes external to the product such as electric power fluctuations or failure f Use of supplies or parts not meeting International Ozone Technologies Group Inc specifications g Normal wear and tear h Any other cause which does not relate to a product defect I Shipping Handling to or from International Ozone Technologies Group Inc 3 Removal installation and set ...

Страница 5: ...electrical power specified on the backside of the case Do not attempt to service this product yourself as opening or removing the enclosure may expose you to dangerous voltage or other hazards Do not put foreign objects inside the equipment Do not operate equipment with a damaged cord or plug if fans fail to rotate after the equipment malfunctions or if it has been dropped or damaged in any manner...

Страница 6: ...amp environment This equipment should only be operated using a properly grounded electrical outlet International Ozone Technologies Group Inc assumes no liability for damages or injuries incurred by misuse of this equipment 4 13 Titan 4000 Is it an Air Purifier That Scrubs The Air Or An Air Scrubber That Purifies The Air ...

Страница 7: ... use at any time with or without people or animals in the treatment area NOTE 60 humidity is required for optimum performance NOTE 60 humidity is required for optimum performance 5 Model 1000 Model 4000 12 Views 5 000 CFM Ball Bearing Fan 4 8 Diameter High Output TiO UVA Photocatalytic 2 Lamps 20 x 20 x 1 2 Permanent Washable Electrostatic Filter 82 Efficient Front Mounted On Off Switch 100 CFM Ba...

Страница 8: ...any variables such as pollutant load temperature humidity etc Examples for 1000 cubic feet 100 Square feet with 10 foot ceilings with lite to moderate odor Titan 1000 3 to 4 Hours Titan 4000 1 Hour As stated above these are just general guidelines In some cases you will have to go longer and in other cases you will go shorter Once you have become experienced with using your Titan for odor removal ...

Страница 9: ...uto Detailers Automobile Rentals Beauty Parlors Nail Salons Bowling Alleys Bus Lines Business Opportunity Businesses Carpet Cleaners Installers Chemical Supply Child Care Centers Cocktail Lounges Bars Condominium Associations Country Golf Clubs Cruise Ships Doctors Dentist Chiropractors and Medical Clinics Dry Cleaners Duct Cleaning Companies Equipment Rental Companies Fire Water Damage Restoratio...

Страница 10: ... call the factory for an RMA number and ship the unit back We will inspect and diagnose the problem If the equipment only needs adjustments or cleaning to bring it back into specifications we will gladly service and re certify your equipment you only pay free of charge shipping and handling are self cleaning and will perform at Titan s Photo Catalytic Lamps their optimum for a period of 8000 hours...

Отзывы: