SERVICE AND TECHNICAL MANUAL

Gas Furnace:  N9MSB

440 04 4411 03

3

Specifications subject to change without notice.

START

UP CHECK SHEET

For PSC Models N9MSB

(This sheet is optional. Keep for future reference.)

Date of Start

Up:

Dealer Name

:

Address

:

City, State(Province), Zip or Postal Code

:

Phone

:

Owner Name

:

Address

:

City, State(Province), Zip or Postal Code

:

Model Number:

Serial Number:

Setup Checks

Check the box when task is complete.

All Electrical Connections Tight?  

Have hoses been relocated for furnace U/D/H application?  

Condensate Drain Connected?   

Condensate Drain Trapped?   

Manual Gas Shut

off Upstream of Furnace/Drip Leg

Gas Valve turned ON?    

Type of Gas:          Natural: 

 

      Propane:  

 

Filter Type and Size:

Check in box the Blower OFF Delay Jumper Heating Position

for Fan “Time 

OFF

” Setting:

1 and 2

2 and 3

3 and 4

5 and 6

90

120

150

180

Calculated Input (BTU) Rate: (See 

Checks and Adjustments

Section).

Heating Check

Measured Line Pressure During Heat:            

Measured Manifold Pressure: 

Heat 

Temperature of Supply Air: 

Heat 

Temperature of Return Air: 

Temperature Rise (Supply 

 Return): Heat 

In Rise Range (see furnace rating plate)?   

Static Pressure (Ducts) High Heat:  Supply   

Return   

The Blower Speed Tap used for: 

Heat 

Optional Check: 

CO?

CO2?

Cooling Check

Temperature of Supply Air: 

 

Temperature of Return Air: 

 

Temperature Difference: 

 

Static Pressure (Ducts) Cooling: 

Supply   

Return  

The Blower Speed Tap used for: 

Cooling  

Dealer Comments:

Содержание N9MSB0401410A

Страница 1: ...colors and or pictures or product labels The signal word WARNING is used throughout this manual in the following manner Safety alert symbol When you see this symbol on the unit and in instructions or...

Страница 2: ...eath WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE...

Страница 3: ...am of Furnace Drip Leg Gas Valve turned ON Type of Gas Natural Propane Filter Type and Size Check in box the Blower OFF Delay Jumper Heating Position for Fan Time OFF Setting 1 and 2 2 and 3 3 and 4 5...

Страница 4: ...structure through drain tube Vent gases contain carbon monoxide which is tasteless and odorless WARNING 1 Remove upper and middle collector box drain plugs opposite of the condensate trap See Figure...

Страница 5: ...e at installed altitude from local gas supplier 2 Obtain average yearly gas specific gravity from local gas supplier 3 Find installation altitude range for your installation in the manifold pressure t...

Страница 6: ...manifold pressure is outside this range change main burner orifices h When correct input is obtained replace cap that conceal gas valve regulator adjustment screw Main burner flame should be clear blu...

Страница 7: ...S CONNECTOR TRANSFORMER 24 VAC CONNECTIONS P2 HOT SURFACE IGNITOR HSI INDUCER MOTOR IND CONNECTOR 115 VAC L1 LINE VOLTAGE CONNECTION SPARE1 COM BLUE 115 VAC L2 NEUTRAL CONNECTIONS 24 V THERMOSTAT TERM...

Страница 8: ...300 21 171 343 857 62 58 116 290 22 164 327 818 64 56 112 281 23 157 313 783 66 54 109 273 24 150 300 750 68 53 106 265 25 144 288 720 70 51 103 257 26 138 277 692 72 50 100 250 27 133 267 667 74 48 9...

Страница 9: ...42 3 4 42 3 5 42 3 6 3001 800 43 3 8 42 3 2 42 3 3 42 3 4 915 825 43 3 6 43 3 7 43 3 8 42 3 2 850 44 3 8 43 3 5 43 3 6 43 3 7 875 44 3 6 44 3 7 43 3 4 43 3 5 4000 900 44 3 4 44 3 5 44 3 7 44 3 8 1219...

Страница 10: ...ding Leaving blower door off will result in incorrect temperature measurements due to possible changes in duct static pressure and airflow FURNACE DAMAGE HAZARD Failure to follow this caution may resu...

Страница 11: ...draw readings can be obtained at the wires normally connected to thermostat sub base terminals R and W The thermostat anticipator should NOT be in the circuit while measuring current 1 Remove thermost...

Страница 12: ...65 1305 1240 1170 1090 990 Orange 1375 1355 1330 1300 1260 1210 1155 1090 1025 940 Blue 1045 1040 1030 1010 985 960 920 875 825 745 Red 5 880 865 850 835 810 785 750 715 665 605 0802120 BOTTOM or TWO...

Страница 13: ...nt location accordingly Figure 6 Multipoise Orientations A93041 Electrical Controls and Wiring ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death There may...

Страница 14: ...LED 6 A component test sequence will follow 7 Reinstall the Main Control door Component Self Test NOTE The furnace control component test allows all components to run for a short time except the gas v...

Страница 15: ...rvice as necessary 4 Inspect burner compartment before each heating season for rust corrosion soot or excessive dust If necessary have furnace and burner serviced by a qualified service agency 5 Inspe...

Страница 16: ...t on blower wheel remove wheel from the blower housing and wash it with an appropriate degreaser To remove wheel a Mark blower wheel location on shaft before disassembly to ensure proper reassembly b...

Страница 17: ...old or damaging the mounting to the burner assembly ELECTRICAL SHOCK AND FIRE HAZARD Failure to follow this warning could result in personal injury death and or property damage Turn off the gas and el...

Страница 18: ...furnace through two complete heating cycles to check for proper operation 18 Install control door when complete Servicing Hot Surface Igniter The igniter does NOT require annual inspection Check ignit...

Страница 19: ...ndensate trap and collector box 5 Secure tubing to prevent any sags or traps in the tubing 6 Connect condensate drain elbow or drain extension elbow to the condensate trap 7 Connect the leads of the c...

Страница 20: ...nditioned space where the ambient temperatures may be 32_ F 0_ C or lower freeze protection measures must be taken to prevent property or product damage CAUTION Since the furnace uses a condensing hea...

Страница 21: ...SERVICE AND TECHNICAL SUPPORT MANUAL Gas Furnace N9MSB Specifications subject to change without notice 440 04 4411 03 21 Figure 14 Service Label 338310 2 Rev F...

Страница 22: ...SERVICE AND TECHNICAL SUPPORT MANUAL Gas Furnace N9MSB Specifications subject to change without notice 22 440 04 4411 03 Figure 15 Wiring Diagram 339241 2 Rev A...

Страница 23: ...quence Gas valve and humidifier will not be turned on Inducer motor will start and remain on until the end of the blower test then off The following components are on for 10 15 seconds each individual...

Страница 24: ...onent test Does the igniter glow orange white by the end of the 15 second warm up period Unplug igniter harness from control and repeat component test Check for 115V between connector P2 HSI and NEUTR...

Страница 25: ...is energized Simultaneously the electronic air cleaner terminal EAC is energized and remains energized as long as the blower motor BLWM is energized f Heat Off Delay When the thermostat is satisfied t...

Страница 26: ...dule when used Inducer motor capacitor when used Collector box Condensate trap Condensate trap elbow Gaskets WARNING FIRE EXPLOSION ELECTRICAL SHOCK AND CARBON MONOXIDE POISONING HAZARD Failure to fol...

Страница 27: ...Two stage FEATURE B Base AFUE Efficiency E Extra AFUE Efficiency C Communicating D Dual Certified 2 pipe or 1 pipe R 2 pipe only S Single stage T Two stage N Standard L Low Nox FEATURE 040 40 000 BTU...

Отзывы: