ELECTRICAL DATA

Table 6—Electrical Data

Console and Floor Ceiling Size

12K

18K

24K

36K

48K

58K

(208/230V)

(208/230V)

(208/230V)

(208/230V)

(208/230V)

(208/230V)

FLA

0.21

1.11

1.11

1.36

0.94

1.2

Input

W

66.6

100

100

130

98

210

Rated HP

HP

0.027

0.075

0.075

0.156

0.122

0.218

LEGEND

FLA - Full Load Amps

CONNECTION DIAGRAM

Fig. 27

 - 

Connection Diagram

Notes

:

1. Do not use thermostat wire for any connection between indoor and outdoor units.
2. All connections between indoor and outdoor units must be as shown. 

The connections are sensitive to polarity and improper termination will result in a fault

code.

A150635

Fig. 28

 - 

Control and Power Wiring on Indoor Unit

NOTE:  For applications where gravity cannot be used for drainage, a condensate pump accessory is available. Consult the condensate
pump installation instructions for more information.

Содержание DLFLFA

Страница 1: ...stallation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS LIST CONSOLE 3 SYSTEM REQUIREMENTS 4 WIRING 4 DIMENSIONS 5 CLEARANCES 7 INSTALLATION LOCATION REQUIREMENTS 8 INDOOR UNIT INSTALLATION CO...

Страница 2: ...ntifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practi...

Страница 3: ...louver at air outlet Air inlet with air filter inside INDOOR UNIT 6 Drain pipe Fig 2 Parts List Console Sizes 18 58 Note If the outdoor unit is higher than the indoor unit prevent rain from flowing i...

Страница 4: ...insulation rating power communication wiring from the outdoor unit to indoor unit consists of four 4 wires and provides the power for the indoor unit Two wires are line voltage AC power one is communi...

Страница 5: ...ice DIMENSIONS 0 63 16 Drain pipe 7 68 195 Hanging arm Unit in mm 27 56 700 23 62 600 8 27 210 Fig 3 Dimensions Table 2 Indoor Unit Console Dimensions UNIT SIZE 12 Depth in mm 8 27 210 Width in mm 27...

Страница 6: ...204mm 8 7in 222mm 8 6in 220mm Fig 4 Dimensions Table 3 Indoor Unit Floor Ceiling Dimensions UNIT SIZE 18K 24K 36K 48K 60K Height in mm 9 25 235 9 25 235 9 25 235 9 25 235 9 25 235 Width in mm 42 05 1...

Страница 7: ...32801000401 7 Specifications subject to change without notice CLEARANCES Fig 5 Indoor Unit Clearance Console...

Страница 8: ...ft the unit and mount it on the hooks Be sure the hooks are on the correct mounting locations on the back of the unit see Fig 7 Washer Tapping screw Hook 6mm Fig 7 Hang the indoor unit DRILL A HOLE IN...

Страница 9: ...e the roof beam to avoid any vibration DRILL A HOLE IN THE WALL FOR THE INTERCONNECTING PIPING DRAIN AND WIRING 1 For maximum serviceability it is recommended that you have the refrigerant line flare...

Страница 10: ...MAX MIN 1 4 6 35 0 05 1 3 0 03 0 7 3 8 9 52 0 06 1 6 0 04 1 0 1 2 12 7 0 07 1 8 0 04 1 0 Bar Copper pipe Clamp handle Red arrow mark Cone Yoke Handle Bar Fig 21 Clamp Handle 5 Apply a small amount of...

Страница 11: ...hen installing condensate piping follow these recommendations S Condensate piping should slope downward in the direction of the condensate flow with a minimum gradient of 1 in per 100 inches S When mu...

Страница 12: ...Load Amps CONNECTION DIAGRAM Fig 27 Connection Diagram Notes 1 Do not use thermostat wire for any connection between indoor and outdoor units 2 All connections between indoor and outdoor units must b...

Страница 13: ...itioner from being activated for approximately 3 to 4 minutes 2 Press MODE and select COOLING HEATING FAN mode to check if all functions work correctly 3 To run the test using the manual button in the...

Страница 14: ...short circuit 7 times X EC Refrigerant leakage detection 8 times X EE Water level alarm malfunction 1 time O F0 Current overload protection 2 times O F1 Open circuit or short circuit of outdoor ambien...