7. Configuration modes and utilities
RS-232 slave mode
124
ScanPlus S Series - Installation Manual
RS-232 slave mode
optimized security transmission (9600, 7, E, 2)
\41\4A\01\29\60
- allows the ScanPlus to be configured or
controlled directly by the terminal host system
via the RS-232 output port
- optimized high-security Code 128 transmission
(start/stop, hexadecimal characters, checksum)
1. use "display data string mode" (see above) to display on a terminal screen the data string
and checksum for the setup commands you want to send to the ScanPlus in slave mode
(the EasySet "View - Data String" command displays the command data strings but does not
display the checksum !)
Example: "Code 39 - active" = \ 41 \ 4C \ 60 \ 5E ("5E" = checksum)
2. remove the backslash separator characters from the data strings and adapt each string to
slave mode format :
<start> <command>
<checksum>
<stop>
< 6 8 > x x x x x x
x x
< 6 A >
Example: slave mode command = 6 8 4 1 4 C 6 0 5 E 6 A
3. activate RS-232 slave mode with the "optimized security transmission" option and
reconfigure the standard RS-232 output parameters to suit your system if required
- the ScanPlus goes into "temporary configuration mode" (see "temporary configuration
mode" below)
4. send the commands from the host terminal to the ScanPlus (individually or as a list in a
batch file)
- the values displayed in "display data string mode" are hexadecimal values, make sure that
the values you send from the host system correspond to these values - in our example, the
ScanPlus must receive the hexadecimal value 41 or its equivalent (ASCII character "A" for
example), not the decimal value "41" !
5. send "update current configuration" (see "temporary configuration mode" below) if you want
to save the new configuration you have sent to the ScanPlus
6. reselect your normal RS-232 interface setting (section 3) to quit RS-232 slave mode and
reconfigure the RS-232 output parameters to suit your system if required
Содержание ScanPlus S Series
Страница 1: ...P N 0 360049 02 ScanPlusSSeries Installation Manual ...
Страница 8: ...Contents 8 ScanPlus S Series Installation Manual ...
Страница 14: ...2 Reset all parameters 14 ScanPlus S Series Installation Manual ...
Страница 68: ...4 Data transmission settings OCIA cash registers 68 ScanPlus S Series Installation Manual ...
Страница 83: ...5 Symbologies Code 93 ScanPlus S Series Installation Manual 83 minimum length 6 45 42 06 60 ...
Страница 91: ...5 Symbologies Matrix 2 of 5 ScanPlus S Series Installation Manual 91 minimum length 6 46 59 06 60 ...
Страница 120: ...6 Operating settings beeps green indicator LED 120 ScanPlus S Series Installation Manual ...
Страница 150: ...C Number codes 150 ScanPlus S Series Installation Manual 8 18 60 9 19 60 end selection 64 60 ...
Страница 156: ...Index 156 ScanPlus S Series Installation Manual ...