Intermec Sabre 1551A Скачать руководство пользователя страница 99

Glossary

G-5

G

Interleaved 2 of 5

A high density, self checking, continuous numeric symbology,
used in the distribution industry.

keyboard wedge mode

An operating method for the scanner that lets it be connected to
a PC by attaching it to the keyboard. This mode is useful for
PCs that do not have an extra serial communication port.

laser redundancy

A feature that checks each scan by creating a duplicate scan and
comparing the information.

laser scanner

See Scanner

modulo 43

A character within a string of data that performs a
mathematical check to ensure the accuracy of the data.

number system digit

The character in some UPC symbols that precedes the bar coded
information.

OCIA

Optical Coupled Interface Adapter. A type of interface that
allows the scanner to transmit bar code data to cash registers.

OCR

Optical Character Recognition. A process in which a machine
processes scanned information in an optical character format.

Содержание Sabre 1551A

Страница 1: ...P N 063496 003 DecodingLaserScanner User s Manual...

Страница 2: ...Intermec manufactured equipment and is not to be released reproduced or used for any other purpose without written permission of Intermec Information and specifications in this manual are subject to...

Страница 3: ...e manual was originally released as version 001 Version Date Description of Change 002 6 96 Revised and reorganized to include the 1551 scanners 003 12 96 Revised to include international keyboards ca...

Страница 4: ......

Страница 5: ...packing the Scanner 1 3 Installation Equipment 1 4 Connecting the Scanner 1 4 15XXX02 Decoding Laser Scanner 1 5 15XXX03 Decoding Laser Scanner 1 6 15XXX07 Decoding Laser Scanner 1 9 Operating the Sca...

Страница 6: ...canner 3 5 Displaying Current Configuration 3 6 Resetting Default Values 3 6 Configuring Bar Code Symbologies 3 7 UPC A and UPC E 3 8 UPC Number System Digit 3 9 UPC Check Digit 3 9 EAN JAN 3 9 EAN JA...

Страница 7: ...XXX02 Serial Parameters 3 27 Baud Rate 3 27 Intercharacter Delay 3 28 Label Buffer 3 29 Setting Up the Bar Code Data String 3 29 Selecting a Protocol 3 31 Configuring the Scanner for Wand Emulation to...

Страница 8: ...Decoding Laser Scanner User s Manual viii Hexadecimal Conversion Chart Configuration Command List Glossary Index A B G I...

Страница 9: ...in this book before handling and operating Intermec equipment You can be seriously injured and equipment and data can be damaged if you do not follow the safety warnings and cautions Do not repair or...

Страница 10: ...be strictly observed to avoid death or serious injury to the persons working on the equipment Avertissement Un avertissement vous avertit d une proc dure de fonctionnement d une m thode d un tat ou d...

Страница 11: ...the scanner Chapter 1 tells you how to connect the scanner to your terminal Operating the scanner Chapter 2 explains how to operate troubleshoot and maintain the scanner Configuring the scanner Chapt...

Страница 12: ...d DA Conventions for Input From a Keyboard or Keypad When you need to press keys on your terminal or reader they are emphasized in bold For example press Enter means you press the key labeled Enter on...

Страница 13: ...t Italic text Italics indicate a variable which you must replace with a real value such as a two letter bar code syntax Brackets enclose a parameter that you may omit from the command Do not include t...

Страница 14: ......

Страница 15: ...Connecting the Scanner 1...

Страница 16: ......

Страница 17: ...guide for your scanner or contact your local Intermec representative for a list of the specific terminals 15XXX07 Keyboard wedge interface for use with personal computers PC through a keyboard or with...

Страница 18: ...hands free operation You must order the appropriate interface cables separately See the quick reference guide for your scanner or call your local Intermec representative for help ordering cables Conne...

Страница 19: ...2 Make sure the terminal is turned off Then connect the D type connector end of the cable to the serial port 3 Connect the external power supply cable to the side of the D type connector 4 Plug the e...

Страница 20: ...551 models have a screw to tighten that secures the plug in the handle Note The interface cable has either an 8 pin SDL synchronous data link connector for the 5B port on the POS terminal or a 4 pin S...

Страница 21: ...ning tips and how to use with the scanner stand for hands free scanning To change the scanner configuration see Chapter 3 To connect the 1551X03 scanner to an OCIA port 1 Insert the scanner end of the...

Страница 22: ...Default when using the Reset to Default Values ZA command The scanner is ready to be used as a hand held scanner and will send data directly to the terminal The default symbologies are UPC A UPC E no...

Страница 23: ...plug in the handle 3 Unplug the keyboard from the terminal and plug it into the short leg of the Y cable 4 Plug the long leg of the Y cable into the terminal where the keyboard was plugged in To conn...

Страница 24: ...used as a hand held scanner and will send data directly to the terminal The default symbologies are UPC A UPC E not expanded Code 39 Code 128 To connect to a laptop or pen based terminal 1 Make sure...

Страница 25: ...ternational keyboard see International Keyboards in Chapter 3 to enable a different language IBM PS2 Model 57 25 laptop interface C9 IBM PC AT laptop interface ThinkPad A Zenith CruisePAD CF Default 6...

Страница 26: ......

Страница 27: ...Operating the Scanner 2...

Страница 28: ......

Страница 29: ...safety instructions in this chapter Keep that guide near your scanner for quick reference Scanner Light The light indicates the status of the scanner Light Description Yellow The device is scanning G...

Страница 30: ...ps The bar code information has not been sent to the terminal successfully See Troubleshooting later in this chapter You can also send a command to make the scanner beep See Remote Beep in Chapter 3 O...

Страница 31: ...e quickest at an angle If the bar code is on a reflective surface or you are scanning straight at perpendicular to the bar code the beam temporarily dims or disappears but the scanner can still read t...

Страница 32: ...he column height so the scanner laser beam covers the entire reflective label 4 Place a bar code right side up over the reflective label When the scanner emits a single beep and or the scanner light t...

Страница 33: ...Configuring Bar Code Symbologies in Chapter 3 Scanner does not read the correct uppercase or lowercase letter or number and symbol If you use the Caps Lock on your terminal you must enable the Shift A...

Страница 34: ...on Scanner does not emit a beam and does not operate The scanner is not receiving power Make sure the scanner cables are securely plugged in and the terminal is on Replace damaged cables If you contin...

Страница 35: ...Configuring the Scanner 3...

Страница 36: ......

Страница 37: ...you must scan the bar codes When the 15XXX02 is used with a portable reader all serial communications functions are disabled Serial communications parameters and portable reader parameters are activa...

Страница 38: ...s values for minimum length use the two letter bar code for the command For example Command Function STX ESC PC ETX Enable I 2 of 5 with check digit STX ESC PD12 ETX Set I 2 of 5 minimum length to 12...

Страница 39: ...ceives a correctly formatted command it sends a confirmation back to the host followed by an ACK 06H If the scanner receives an unknown command an improperly formatted command or a command accompanied...

Страница 40: ...on the application Display Current Configuration ZB Transmit Program Version ZC Transmit Program Version number displays as two decimal places followed by commands for carriage return and line feed R...

Страница 41: ...ulation white high 50 ips Communications 9600 e 7 1 Z5 Configuring Bar Code Symbologies You can configure these symbologies on your scanner UPC A UPC E EAN JAN Code 39 Standard 2 of 5 Interleaved 2 of...

Страница 42: ...or 5 digits lets the scanner read the supplement as well Enable UPC A and UPC E Supplement allowed QB Enable UPC A and UPC E Supplement disabled QC Enable Expanded UPC E QI Disable Expanded UPC E QH E...

Страница 43: ...he last character in a UPC symbol Enabled QG Disabled QF Default for all modes EAN JAN Scan the appropriate code to enable or disable EAN 8 digit and 13 digit When EAN JAN is enabled all EAN JAN codes...

Страница 44: ...e or disable the number system digit the first character in a UPC symbol Disable Number System Digit RD Enable Number System Digit RE EAN JAN Check Digit Scan a bar code to enable or disable the check...

Страница 45: ...3 Check Character OD Enable Modulo 43 Check Character OE Transmit START and STOP Characters OG Do not transmit START and STOP Characters OF Default for 15XXX02 and 15XXX07 scanners Default for all mod...

Страница 46: ...s To set the bar code length optional 1 Scan the appropriate bar code below Minimum Length PH Maximum Length PI 2 Enter a length between 01 and 32 using the conversion chart in Appendix A Interleaved...

Страница 47: ...2 and 32 using the conversion chart in Appendix A Code 128 These bar codes configure your scanner for Code 128 scanning Enable TB Disable TA Default for 15XXX02 and 15XXX07 scanners To set the bar cod...

Страница 48: ...ies Enable VB Disable VA Transmit START and STOP characters VD Do not transmit START and STOP characters VC Default for all scanners To set the bar code length optional 1 Scan the appropriate bar code...

Страница 49: ...ies Disable UA Enable Code 93 UB Standard Code 93 UC Enable Full ASCII Code 93 UD Default for 15XXX02 and 15XXX07 scanners To set the bar code length optional 1 Scan the appropriate bar code below Min...

Страница 50: ...e Code 11 With One Check Digit SB Enable Code 11 With Two Check Digits SC Disable Transmit of Code 11 Check Digits SD Enable Transmit of Code 11 Check Digits SE To set the bar code length optional 1 S...

Страница 51: ...r code ID Preamble Postamble Prefix The prefix identifies the start of a data string and is represented by a code that is determined by an industry standard The prefixes available are STX start of tra...

Страница 52: ...I code that conforms to a standard The available suffixes are CR carriage return LF line feed CR and LF ETX end of transmission and HT horizontal tab Scan a bar code to enable the suffix used with you...

Страница 53: ...wo digits between 01 and 99 using the conversion chart in Appendix A Bar Code ID If your system uses different types of bar code symbologies it may require a bar code ID The ID is a single character t...

Страница 54: ...represented by two hexadecimal numbers If they are used in your system only those codes with the correct preamble and postamble are accepted To configure a preamble or a postamble 1 Scan one of these...

Страница 55: ...acters International Keyboards Power Consumption Power consumption parameters determine if the scanner reverts to standby when not scanning With standby enabled the scanner draws very little power bet...

Страница 56: ...t AD Default Laser Redundancy Laser redundancy checks each scan by creating a duplicate scan and comparing the information which must match for a successful read This feature increases the integrity o...

Страница 57: ...potter beam Disable Spotter Beam NP Enable Spotter Beam NQ 2 If you scan Enable Spotter Beam enter a spotter beam duration between 0 and 9 using the conversion chart in Appendix A External Trigger The...

Страница 58: ...Disabled HA External Trigger HE External Trigger HF Default Reading Uppercase Letters When the Caps Lock key is used on the reader terminal you must also configure the scanner to read and decode the u...

Страница 59: ...able or disable shift lock not available for 15XXX02 and 15XXX03 Enable Shift Lock ES Disable Shift Lock ET Note To read uppercase letters see the previous section Reading Uppercase Letters Internatio...

Страница 60: ...erman Keyboard Wedge L DEC VT 220 320 420French Keyboard Wedge M Using an International Keyboard With a Laptop If you use a laptop with an international keyboard you need to enable the keyboard Scan a...

Страница 61: ...using your 15XXX02 scanner with a portable reader you must configure the scanner by scanning the bar codes in this manual If you are configuring the scanner from a host terminal see Configuring the Sc...

Страница 62: ...racter delay simulates keystroke input by inserting a delay between transmission of characters The delay is a certain number of milliseconds set separately when you enable this parameter To set the in...

Страница 63: ...r the previous label to be transmitted No buffer You cannot scan the next label until the previous one has been completely transmitted One label buffer You can scan ahead one label only Scan a bar cod...

Страница 64: ...stem Data Setup 1 start bit 7 data bits 1 stop bit Odd Parity ED Even Parity EC Mark Parity EB Space Parity EA Default for Serial mode Data Setup 1 start bit 7 data bits 2 stop bit Odd Parity EH Even...

Страница 65: ...n it is ready to receive data and sends the XOFF character when the buffer is full and cannot accept data No additional hardware is needed only transmit receive and signal ground are required Clear to...

Страница 66: ...TS high when scanner ready to receive HA Note CTS may be programmed independently of RTS however the polarities must match You cannot select CTS and fix RTS RTS low when scanner ready to receive HI RT...

Страница 67: ...stand Otherwise your terminal may register a scanner failure or you may cause damage to the terminal or the scanner 3 Connect the scanner to the reader using the cables for your scanner For help see y...

Страница 68: ...bar code symbology you can configure your scanner to convert to Code 39 before it transmits the data to the portable reader To convert to Code 39 full ASCII before transmitting scan this code Transmit...

Страница 69: ...at the terminal again scan this bar code Note for 15XXX07 users If your scanner is interfaced through a keyboard scanning CA will enable Serial mode Scan CE next bar code before reconnecting your sca...

Страница 70: ...figuring the Scanner for Use With an Intermec 94XX and 95XX Reader These steps are a quick way to enable wand emulation to an Intermec 94XX or 95XX reader when the scanner is connected with a smart ca...

Страница 71: ...Hexadecimal Conversion Chart A...

Страница 72: ......

Страница 73: ...number must be scanned first 4 Locate the number or letter at the left of the table in bold for the row containing the character 5 Scan the bar code for that number or letter For example the hexadeci...

Страница 74: ...nual A 4 Hexadecimal Conversion Table 0 1 0 1 2 3 2 0 1 2 3 NUL SOH STX ETX DLE DC1 DC2 DC3 SP 0 1 2 3 3 4 5 6 7 EOT ENQ ACK BEL DC4 NAK SYN ETB 4 5 6 7 4 8 9 A B BS HT LF VT CAN EM SUB ESC 8 9 5 C D...

Страница 75: ...Hexadecimal Conversion Chart A 5 A 8 9 4 5 6 7 0 1 2 3 A B C P Q R S a b c p q r s A 4 5 6 7 D E F G T U V W d e f g t u v w B 8 9 A B H I J K X Y Z h i j k x y z C C D E F L M N O _ l m n o DEL D E F...

Страница 76: ......

Страница 77: ...Configuration Command List B...

Страница 78: ......

Страница 79: ...X02 scanner in Serial mode using the two letter bar code syntax See Configuring the Scanner in Chapter 3 The commands are listed in alphabetic order by syntax Command Syntax Bar Code Continuous Power...

Страница 80: ...eset K DEC VT220 320 420 German Keyboard Wedge L DEC VT220 320 420 French Keyboard Wedge M Beeper Volume Control Off AA Beeper Volume Control Low AB Beeper Volume Control Medium AC Beeper Volume Contr...

Страница 81: ...interface C9 Select Primary Communications Port Cancel Wand Emulation CA Select Wand Emulation Code 39 Full ASCII CB Select Wand Emulation Same Code Emulation CC Inverted Serial Communications CD Wed...

Страница 82: ...Terminal CZ Select NEC Powermate SX20 Keyboard C0 Select IBM 3151 With Break Codes C1 Select Sperry PC With Keytronics Keyboard C4 Select Unisys B26 Keyboard Wedge C6 Enable Fast PC AT Keyboard Hong K...

Страница 83: ...nd Syntax Bar Code Commands EA to EN are serial data word commands 7 Low 1 EA 7 High 1 EB 7 Even 1 EC 7 Odd 1 ED 7 Low 2 EE 7 High 2 EF 7 Even 2 EG 7 Odd 2 EH 8 Low 1 EI 8 High 1 EJ 8 Even 1 EK 8 Odd...

Страница 84: ...e in milliseconds 00 99 GB Turn Off the Interlabel Delay GC Set the Interlabel Delay Two digit argument is the delay time in 100 milliseconds intervals 00 99 GD HA to HK are serial communication comma...

Страница 85: ...IC Disable Unit ID JA Enable Unit ID The arguments are a two digit unit ID number ID s are in the range 01 99 JB Disable Preamble KA Set Four Character Preamble Unused characters are set to Null The f...

Страница 86: ...le Label Buffering NC Enable Label Buffering and Power Conservation Clear the label buffer ND Enable Full Serial Buffering NE Enable No Serial Buffering NF One Label Buffer NG Select Wide Normal Scan...

Страница 87: ...Two digit argument is the length 01 32 OH Set Maximum Length Two digit argument is the length 01 32 OI Enable Transmit of Check Character This command and the next are responsible for controlling the...

Страница 88: ...nt is the length 02 32 Length must be a multiple of two Round all entries up to the next even number Becomes 2nd fixed length for 3 fixed length option PE Disable Standard 2 of 5 PF Enable Standard 2...

Страница 89: ...PC E only QF Enable Transmit of the UPC Check Digit UPC A and UPC E only QG Disable Expansion of UPC E QH Enable Expansion of UPC E QI Enable EAN Emulation by UPC A Symbols Forces UPC A to be decoded...

Страница 90: ...ements QX Disable Supplement Delimiter QY Enable Supplement Delimiter QZ Disable Mandatory Supplements for UPC EAN Q0 Enable Mandatory Supplements for UPC EAN Q1 Disable UPC E1 Symbology Q2 Enable All...

Страница 91: ...f the laser and transmit the labels one after the other Note These bar codes will not be concatenated upon transmit RH Enable Stacked EAN 13 RI Disable EAN 8 Transmission of Check Character RJ Enable...

Страница 92: ...o digit argument is the length 01 32 SG Disable Code 128 TA Enable Code 128 TB Set Minimum Length for Code 128 Two digit argument is the length 01 32 TC Set Maximum Length for Code 128 Two digit argum...

Страница 93: ...for Codabar Two digit argument is the length 01 32 VE Set Maximum Length for Codabar Two digit argument is the length 01 32 VF Enable Transmit of Codabar Start Stop as Lowercase Characters VG Wand Em...

Страница 94: ...l Key YK Reset to Primary Communications Defaults ZA Dump Status Serial Communications Models Only ZB Dump Version Serial Communications Models Only ZC Scan and Transmit Label Serial Communications Mo...

Страница 95: ...Glossary G...

Страница 96: ......

Страница 97: ...one device to another The number of bits symbols or digits per second that are transmitted check digit A bar coded character in some UPC symbols that follows the bar coded information and serves as a...

Страница 98: ...has both a version that uses 8 digits and a version that uses 13 digits EEPROM Electrically Erasable Programmable Read Only Memory A form of semiconductor memory in which the entire contents can be e...

Страница 99: ...hecks each scan by creating a duplicate scan and comparing the information laser scanner See Scanner modulo 43 A character within a string of data that performs a mathematical check to ensure the accu...

Страница 100: ...a host terminal that controls data flow RS 232 A widely used standard interface for connections between data communication equipment scan To read a bar code by scanning with a laser scanner that conv...

Страница 101: ...ons port rather than by scanning the configuration bar codes standby mode A configuration that lowers power consumption when the scanner is idle start and stop characters Special bar code characters a...

Страница 102: ...ntegrated circuits whose principle switching components are bipolar transistors UPC Universal Product Code used in the supermarket industry since 1973 A fixed length numeric continuous symbology emplo...

Страница 103: ...Index I...

Страница 104: ......

Страница 105: ...3 12 parameters bar code ID 3 19 preamble and postamble 3 20 prefix 3 17 suffix 3 18 terminal ID 3 19 polarity for portable readers 3 34 prefix 3 17 scanning techniques 2 5 suffix 3 18 troubleshootin...

Страница 106: ...p volume 3 22 external trigger 3 23 international keyboards 3 25 laser redundancy 3 22 power consumption 3 21 reading symbols 3 25 reading uppercase letters 3 24 spotter beam 3 23 Portuguese keyboard...

Страница 107: ...BM PC XT 1 10 IBM PS 2 model 50 60 80 1 10 IBM PS2 Model 25 30 57 1 10 1 11 ID bar code 3 19 terminal 3 19 installing 15XXX02 1 5 15XXX03 1 6 15XXX07 1 9 equipment 1 4 RS 232 scanner 1 5 scanner to an...

Страница 108: ...reading symbols 3 25 reading uppercase letters 3 24 spotter beam 3 23 P parameters displaying current settings 3 6 operating beep volume 3 22 external trigger 3 23 international keyboards 3 25 laser...

Страница 109: ...ing 2 4 remote beep 3 5 speed improving 3 7 stand enabling 2 6 troubleshooting 2 7 scanning bar code distance 2 5 bar code far away 3 23 duplicate 3 22 hand held 2 4 tips 2 5 unreadable bar codes 3 34...

Страница 110: ...canner 1 3 terms defined in glossary G 3 in the manual xi tips for scanning 2 5 transmission rate for portable readers 3 34 transmitting converting to Code 39 before 3 34 trigger external 3 23 trouble...

Отзывы: