background image

Chapter 1 — Introduction 

MobileLAN power User’s Guide 

About the Power Bridge 

The Power Bridge is a single Ethernet channel power-feeding 
device. It is designed for use with a 10BaseT/100BaseTx standard 
Ethernet network over a standard TIA/EIA-568 Category 5 (or 
higher) cabling plant. The DC operating power for the data 
terminal units is fed through the unused pairs (7/8 and 4/5). 

The Power Bridge normally powers devices that are Power over 
Ethernet Enabled; that is, they are equipped to receive power over 
Ethernet. Devices that are not equipped to receive power over 
Ethernet can be powered by the Power Bridge, but they require an 
external splitter. 

The Power Bridge has the following features: 

• 

Remote power feeding of Ethernet terminals 

• 

A single 10BaseT/100BaseTx data + power combined channel 

• 

Universal 90 to 264 VAC, 50 to 60 Hz power input  

• 

Port overload and short-circuit protection  

• 

Port status LEDs 

• 

15.4W minimum allowable output power 

• 

Free-standing or wall-hanging mounting 

The Power Bridge also eliminates the need for terminal’s AC 
outlets, UPS, and AC/DC adapters. 

Содержание MobileLAN access

Страница 1: ...MobileLAN power User s Guide ...

Страница 2: ...urpose without written permission of Intermec Information and specifications in this manual are subject to change without notice 2003 by Intermec Technologies Corporation All Rights Reserved The word Intermec the Intermec logo INCA under license MobileLAN JANUS IRL Trakker Antares EZBuilder TE 2000 Data Collection Browser dcBrowser Data Collection PC Universal Access Point UAP Duratherm EasyCoder ...

Страница 3: ...ge Record This page records the changes to this document The manual was originally released as version 001 Version Date Description of Change 002 03 03 Updated information to remove references to the Power Not Active LED Made other small changes ...

Страница 4: ...iv MobileLAN power User s Guide ...

Страница 5: ...er Bridge Front View Detail 3 Power Bridge Rear View Detail 4 Power Bridge Status LEDs 5 Powering Ethernet Devices 6 Installing the Power Bridge 7 Verifying Kit Contents 8 Recording Identification Information 8 Choosing a Suitable Site 8 Mounting the Power Bridge 9 Free Stand Mounting 9 Wall Hanging 9 Cabling the Power Bridge 10 Connecting Cables to the Power Bridge 11 Connecting Cables to End Dev...

Страница 6: ...tion 15 Important Safety Information 16 Power Cord Set 18 Specifications and Troubleshooting 19 Technical Specifications 20 Physical Specifications 20 Environmental Specifications 20 Electrical Specifications 20 Ethernet Interface 20 Troubleshooting 21 A B ...

Страница 7: ...safety is extremely important Read and follow all warnings and cautions in this book before handling and operating Intermec equipment You can be seriously injured and equipment and data can be damaged if you do not follow the safety warnings and cautions Do not repair or adjust alone Do not repair or adjust energized equipment alone under any circumstances Someone capable of providing first aid mu...

Страница 8: ...ssements comprennent des instructions qui doivent être respectées pour assurer la sécurité des personnes et de l équipement Respectez scrupuleusement toutes les instructions A caution alerts you to an operating procedure practice condition or statement that must be strictly observed to prevent equipment damage or destruction or corruption or loss of data Attention Une précaution vous avertit d une...

Страница 9: ...r use by network administrators who are responsible for installing network equipment consequently it assumes a basic working knowledge of LANs Local Area Networks To use this document effectively you should have a working knowledge of Ethernet infrastructures In addition you should have a working knowledge of basic electronics and mechanical assembly as well as an understanding of related local bu...

Страница 10: ...Before You Begin x MobileLAN power User s Guide ...

Страница 11: ...troduces the MobileLAN power bridge and explains how it can be used in your network This chapter covers these topics About the Power Bridge Power Bridge front view detail Power Bridge status indications Power Bridge rear view detail Powering Ethernet devices 1 ...

Страница 12: ...r over Ethernet Enabled that is they are equipped to receive power over Ethernet Devices that are not equipped to receive power over Ethernet can be powered by the Power Bridge but they require an external splitter The Power Bridge has the following features Remote power feeding of Ethernet terminals A single 10BaseT 100BaseTx data power combined channel Universal 90 to 264 VAC 50 to 60 Hz power i...

Страница 13: ...luding the Power Bridge is 100m 328 ft per the IEEE 802 3 standard 10BaseT 100BaseTx Data In Port Right Connector The Power Bridge has a single 10BaseT 100BaseTx data input port configured as Media Dependant Interface MDI non crossover This port is designed to carry Ethernet data only Tx Rx over the standard 2 wire pairs RJ 45 pins 1 2 and 3 6 Power Active LED The Power Active LED green indicates ...

Страница 14: ...ves à la sécurité à l annexe A The Power Bridge automatically adjusts its power setting to any supply voltage from 90 to 240 VAC See Appendix A for proper selection of a power cord Supply Data Label The Supply Data label contains information regarding the total AC power input 100 to 240 VAC power frequency 60 50 Hz and the corresponding amperes See Appendix A for proper selection of a power cord I...

Страница 15: ...king Overload conditions or shorted terminal port or forced external voltage feed constant DC into the port Power to the port is disconnected No DC voltage is present on the spare pairs Main LED Table Main LED Status Main Power Status Remarks Off Main internal power supply unit is unplugged or faulty AC input is not active On Main power supply unit is plugged in and under normal operating conditio...

Страница 16: ...sed to power access points or other end devices such as IP phones web cameras laptop computers and others That is the Power Bridge can be used to power any Ethernet device with power requirements that are within the specified powering capabilities This illustration shows examples of network configurations ...

Страница 17: ... chapter contains information needed to install the Power Bridge This chapter covers these topics Verifying kit contents Recording identification information Choosing a suitable site Mounting the Power Bridge Powering up the Power Bridge Cabling the Power Bridge 2 ...

Страница 18: ...e safety information provided in Appendix A before carrying out any installation removal or any maintenance procedure on the Power Bridge Avertissement Vous devez lire toutes les informations concernant la sécurité à l annexe A avant d entreprendre l installation le retrait ou toute procédure d entretien du Pont d alimentation The Power Bridge is suited for use in an office environment where it ca...

Страница 19: ...ers and broadband amplifiers power lines and fluorescent lighting fixtures Mounting the Power Bridge Disconnect all cables from the Power Bridge before continuing Attention Déconnectez tous les câbles du Pont d alimentation avant de continuer There are two ways that you can mount the Power Bridge Free stand mounting Wall hanging Free Stand Mounting Place the self adhesive rubber feet provided in t...

Страница 20: ... du Pont d alimentation veuillez tout simplement brancher ou retirer le câble d alimentation de la prise de courant alternatif située à l arrière du Pont d alimentation To power on the Power Bridge 1 Insert a power cord into the power receptacle on the rear of the Power Bridge 2 Insert the other end of the power cord into the wall AC power outlet The Power Bridge powers up and runs through its Pow...

Страница 21: ...idge to the Data In port Power Data Out Ports Using a standard Category 5 or higher straight through cable connect the cable leading to the remote device to the Power Data Out port Splitter Power over LAN Hub 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 RJ 45 IN RJ 45 OUT Ethernet Switch Hub RJ 45 RJ 45 data data data DC data DC data data data data spare spare spare spare Data I...

Страница 22: ...AN Access Point Connecting end devices to the power bridge Since the 2102 is not Power over Ethernet Enabled it must be connected to a splitter before it can be connected to the Power Bridge Before connecting end devices to the Power Bridge determine if the end device is Power over Ethernet Enabled or not Note If the end device is not Power over Ethernet Enabled the end device may be safely connec...

Страница 23: ... end device directly if the device is Power over Ethernet Enabled or by using an external splitter 2 Connect the opposite end of the same cable to the RJ 45 wall outlet Monitor the port LEDs If the Power Active LED lights the Power Bridge has identified your end device as Power over Ethernet Enabled and the port is sending power Refer to Appendix B if needed ...

Страница 24: ...Chapter 2 Installing the Power Bridge 14 MobileLAN power User s Guide ...

Страница 25: ...MobileLAN power User s Guide 15 Safety Information This chapter explains safety information A ...

Страница 26: ...nt Respectez les mesures de sécurité de base en matière d électricité lorsque vous connectez le Pont d alimentation à sa source d alimentation This product relies on the building installation for short circuit overcurrent protection Ensure that a fuse or circuit breaker no larger than 120 VAC 15A U S 240 VAC 10A international is used on the phase conductor Avertissement Ce produit suppose qu une p...

Страница 27: ...nt Avertissement Pour tout équipement autonome assurez vous que la surface est stable et suffisamment solide pour soutenir l équipement Ultimate disposal of this product should be handled according to all national laws and regulations Avertissement L élimination de ce produit doit respecter les lois et les règlements du pays en question The Power Bridge Data In and Power Data Out ports are shielde...

Страница 28: ...to the unit and not the wall plug must have a configuration for mating with an EN60320 IEC320 appliance inlet The socket outlet must be near to the unit and easily accessible You can only remove power from the unit by disconnecting the power cord from the outlet This unit operates under SELV Safety Extra Low Voltage conditions according to IEC 950 The conditions are only maintained if the equipmen...

Страница 29: ...MobileLAN power User s Guide 19 Specifications and Troubleshooting This appendix lists Power Bridge specifications and troubleshooting B ...

Страница 30: ... to 104 F Storage 20 to 70 C 4 to 158 F Humidity 10 to 90 no condensation allowed Electrical Specifications Input Voltage 90 to 264 VAC 47 to 63 Hz Input Current at 110 VAC Input Current at 220 VAC 0 34 Amperes maximum 0 17 Amperes maximum Total Power Consumption Continuous port at full load 22 4 Watts maximum Output Power per port 15 4 Watts Nominal Output Voltage per port 48 VDC 4V Ethernet Inte...

Страница 31: ...at the AC power cord is correct and functioning and that it has a solid ground connection Verify that the AC inlet is supplying power test with a different device and that the voltage is between 100 to 264 VAC 50 to 60 Hz Reconnect the Power Bridge to the AC inlet and verify the LED power up sequence Power Bridge operates but the Main LED is off You may have an internal power supply fault The Powe...

Страница 32: ...sover twisted pair wire Verify that the end device is connected to the Data Power Out port left RJ 45 connector Try to bypass the long twisted pair cable and bring the end device close to the Power Bridge Connect it to the port using a short cable if it works you probably have a faulty connection or short on the long cable or a bad RJ 45 connection along the line If possible try to connect the end...

Страница 33: ...are not using any crossover twisted pair wires Verify that the Power Bridge is connected to a switch hub with a good RJ 45 patch cord connection Try to bypass the long twisted pair cable and bring the end device close to the Power Bridge Connect it to the port using a short cable if it works you probably have a faulty connection or short on the long cable or a bad RJ 45 connection along the line T...

Страница 34: ...6001 36th Avenue West Everett WA 98203 U S A www intermec com 2003 Intermec Technologies Corp All Rights Reserved MobileLAN power User s Guide 072006 002 072006 002 ...

Отзывы: