APPLICATION

The GM40 Multi-Volt Series Time Controls are universal,
electromechanical time switches which can be field config-
ured for various power supply voltages. The voltage options
include 120VAC, 208/240VAC and 277VAC –all within the
same unit! Selection of the desired supply voltage is easily
achieved by selecting the DIP to the corresponding input volt-
age as indicated on the printed circuit board assembly (refer
to “input voltage selection” on page 1). The mechanism is
mounted in a NEMA 3R outdoor enclosure and has been
design for the control of lighting, heating, air conditioning,
pumps, motors, or general electrical circuits in residential,
commercial, industrial and agricultural facilities. All GM40
models are available as “Mechanism Only” (–M) for installation
in other enclosures or control panels or “Bracket Mount” (-B).
The GM40 is also available in a NEMA 1 Indoor Metal
Enclosure (-IM).

SPECIFIERS GUIDE

Furnish and install a Grasslin GM40 _ Multi-Volt Series 24 hour
or (7 day) time switch with captive trippers and quartz or syn-
chronous drive. Input voltage shall be 120, 208/240 or 277VAC
selectable via simple to set DIP switch. All units shall incorpo-
rate both SPDT and DPDT contacts that shall be rated at 40A,
2 HP @ 277V. To set the starting time and to provide time indi-
cation, the unit shall have an authentic clock face with hour
and minute hands. LED indicators shall provide Power and
Status feedback. Enclosure shall be NEMA 3R suitable for

both indoor or outdoor installation. Time switch shall contain
an OFF/AUTO/ON manual override. For Carry-over: The time
switch shall have a quartz drive with 7 day reserve carry-over.

PROGRAMMING INSTRUCTIONS

SETTING THE TIME:

Rotate the program dial gradually

clockwise until the day of the week (7 day) and time of day
on the outer dial is nearly aligned with the triangle marker at
2 o’clock position. Then set time to the minute by rotating
minute hand clockwise.CAUTION: Do not rotate dial or
minute hand counter-clockwise.

PROGRAMMING:

The 24 hour model has trippers of 15

minute increments, and an AM/PM indication on the outer
dial. The 7 day model has trippers of 2 hour increments. The
outer dial shows the 7 days of the week and AM/PM for each
day. Push the captive trippers outward for the time period(s)
that the load is to be on (Normally open contacts closed).

MANUAL OVERRIDE:

With the manual switch in the middle

position, the GM40 is in automatic mode and will switch at the
programmed times. In the upper position “I”, the load is per-
manently ON. In the lower position, “O”, the load is perma-
nently OFF.

BATTERY POWERED RESERVE 
(Quartz Models): 

In case of power failure, the built-in nickel-cadmium battery
maintains the time of day for 7 days. During power outage
relays are de-energized.

The GM40 is the only electromechanical general purpose time switch that offers multi-voltage selection,

SPDT and DPDT contacts, 40Amp rating, indoor and outdoor enclosure – all standard in one model.

NO TOOLS REQUIRED! 

Our “GUTS” simply snap

into existing Grasslin or

Intermatic enclosures

Moisture Resistant 

Conformal Coated Board

Ground Lug Termination

Amber and Green

LED Lights Indicate

Power and Status

Large Screw 

Terminals for Easy Wiring

#8 AWG

40 Amp Rated 

Contacts

Captive Trippers

Can’t Be Lost

Independently

Adjustable Trippers at

15 Minute Intervals

Real-Time Clock Face

New Compact 

VALOX

®

NEMA 3R

Outdoor Enclosure
Replaces All Metal

Enclosures

GM40 – 120, 208/240, or 277 Volts – The only one to stock.

Easy Multi-Voltage

Field Adjustable 

DIP Switch for 

120, 208/240, 

or 277 VAC

File #E83486
Covered by U.S. Patent #6,563,237

NE

W

NE

W

NE

W

NE

W

NE

W

NEW

NEW

NEW

Содержание TimeMaster GM40

Страница 1: ...ngs for conduit and outlet boxes must be used 6 1 8 2 1 2 File E83486 Covered by U S Patent 6 563 2371 Interior Protective Cover Step 1 Diagram not to scale All dimensions in inches Ground Lug Step 2 Timer Mechanism GM40 General Purpose Multi Voltage Commercial Time Switch ELECTRICAL RATINGS N O Contacts 40A Resistive 120 277VAC 1HP 16FLA 90LRA 120VAC 2HP 12FLA 52LRA 208 277VAC 30A Ballast 120VAC ...

Страница 2: ...m dial gradually clockwise until the day of the week 7 day and time of day on the outer dial is nearly aligned with the triangle marker at 2 o clock position Then set time to the minute by rotating minute hand clockwise CAUTION Do not rotate dial or minute hand counter clockwise PROGRAMMING The 24 hour model has trippers of 15 minute increments and an AM PM indication on the outer dial The 7 day m...

Страница 3: ...hase Load TIMER 277VAC N H T NO2 NC2 NO NC L2 N L1 COM COM2 LOAD 1 LOAD 2 Typical Wiring Diagram 277VAC Application Controlling Two 277VAC Loads If GM40 is used to control a single 120VAC load remove jumper wire L2 N to COM2 and keep jumper wire L1 to COM If GM40 is used to control two 120VAC loads remove jumper wire L2 N to COM2 and reposition it to COM to COM2 Note GM40 is shipped with pre insta...

Страница 4: ... Lights Pumps Motor etc does not turn OFF 1 Verify manual override switch is set to the middle position 2 Verify correct programming dial refer to page 2 3 Slide manual override switch located on right side of timer module down The GREEN LED should turn OFF indicating that the output should be OFF Mounting GM40 Mechanism into existing Intermatic Metal Enclosure The GM40 Series printed circuit boar...