MODEL: T51211BC

TWO CIRCUIT SEVEN DAY
TIMING CONTROL CENTER WITH 
SPRING-WOUND CARRY-OVER MOTOR

CIRCUIT A:  PHOTO CONTROL

ON-TIME SWITCH OFF

CIRCUIT B:  PHOTO CONTROL

ON-PHOTO CONTROL OFF

CONTACT RATINGS:
15 AMP., 1/2 H.P. - 125 OR 250 VOLTS A.C.
420 V.A. PILOT DUTY, 150 WATTS TUNGSTEN -120V A.C.

TO CONTROL MECHANICALLY HELD AND MAGNETIC CONTACTORS

(MAY ALSO BE USED WITH 24 VOLT SYSTEMS IF WIRED IN ACCORDANCE
WITH NATIONAL ELECTRICAL CODE REGULATIONS.)

CLOCK MOTOR AND PHOTO CONTROL: 120 VOLTS - 60 HZ.

WIRING INSTRUCTIONS
This center can be programmed to control any lighting and other loads on two circuits, on a
seven day schedule with selected day(s) of the week omitted from circuit 

A. For terminal

markings refer to diagram above. Follow national or local electrical code regulations and
complete wiring as shown. Turn selector switches (bottom front panel) to 

OFF. Replace panel

before turning on electricity. Test each circuit individually.
PROGRAMMING INSTRUCTIONS
1. THE PHOTO CONTROL (INSTALLED OUTSIDE) 
selects the "ON" times depending on time

of season. If fine adjustment is needed move slide on photo control to retard/advance 
"ON" time.

2. TO SET "OFF" TIMES Place dark OFF trippers firmly against dial edge at day-of-week 

and time-of-day when lights are to turn off. 

NOTE: In order to reset time switch, every 

OFF tripper on dial must be followed by an ON tripper. Fasten a bright ON tripper to dial
at any time within the day-light hours of winter, preferably 12 o'clock noon.

3. TO SKIP DAYS ON CIRCUIT A, omit trippers for the day(s) automatic operation(s) is/are 

not required (Circuit B is independently controlled by the photo control).

4. TO SET DIAL TO TIME-OF-DAY turn dial clockwise and align the exact day-of-week 

and time-of-day (AM or PM) on dial with the time pointer. Some allowance may be 
required to compensate for gear backlash. 

CAUTION: Do not force dial counterclock-

wise or move time pointer.

OPERATING INSTRUCTIONS
1. THE THREE POSITION SELECTOR SWITCH 
provide manual control of the two circuits.

When turned to 

ON or OFF, lights or other loads will remain ON or OFF until the switch is 

manually reset. With a switch in 

AUTOMATIC position, operations will follow the preset 

program of the center.

2. IN CASE OF EXTENDED POWER FAILURE OR NEED TO ADVANCE/RETARD TIME

place selector switch in 

OFF position. Reset time-of-day, see step 4 of programming

instructions. Then turn selector switch to 

ON or AUTOMATIC.

BEFORE ANY BEHIND-THE-PANEL WORK DISCONNECT ELECTRICITY

INTERMATIC INCORPORATED

SPRING GROVE, ILLINOIS 60081-9698

158TS10994

LR3730

158TS10994  8/6/04  10:54 AM  Page 1