INSTALLATION

1.  Remove the four #10 hex head screws from the 

  back of the enclosure and attach mounting brackets

  to enclosure.
2.  Select the proper location for the Control and hang

  enclosure on a flat vertical surface or other support,

  using hardware suitable for the purpose. 
3.  Prepare the necessary conduit runs, terminate them

  at both ends and pull in the conductors as specified

  by the installation layout.
4.  Refer to Figure 1 below; 

  note that this enclosure

  contains one or two Time

  Switch(es). To wire the 

  panel, follow the wiring diagram located inside the 

  enclosure door. Make sure that connections to time

  switch terminals are tight (25 lb.-in. minimum) and

  insulation clears the pressure plate - see illustration.
5.  If required by the heater manufacturer, install 

  fireman switch kit 156T4042A (not furnished) 

  on Time Switch Plate and make the fireman switch

  connections. Use at least #18 AWG wiring with 

  insulation rated 300 Volt or higher. Place heater

  ON/OFF switch on heater to ON (see Figure 2).

 

Some heaters may require a special connecting 

  harness, contact heater manufacturer 

  for details.
6.  For direct wiring of underwater lights, the 

  installation must comply with Article 680-21(b) 

  of the National Electrical Code or in Canada,

  Articles 68-060, -062 and -066.
7.  To install additional wiring devices inside the 

  enclosure, first remove rectangular knock-out(s) in

  dead front. Next, remove hex head screws in back 

  of enclosure and install stand-offs* in place of

  screws. Attach wiring device to stand-offs.

  •  Stand-offs are not furnished. Order 21T156A for 

    a set of four (4) stand-offs and mounting hardware.

8.  If external bonding is required, install a bonding 

  lug at bottom of enclosure and bond installation

  according to code requirements.
9.  Testing of the installation is optional and recom-

  mended only if pump is securely in place and will

  not be damaged by this test:
  a. Turn the manual lever of the Time Switch to OFF.
  b. Turn ON power at breaker panel.
  c. Move the manual lever of Time Switch to the 

      right (ON). Pump should start and run on full speed.
  In case of unsatisfactory results, turn OFF power,

  check your wiring, refer to Troubleshooting on Page 3.
10. Install front panel over wiring compartment. 

  The control is now ready for programming, 

  see OPERATION section on Page 3.

IMPORTANT SAFETY INSTRUCTIONS

When installing and operating this Product and other associated equipment, basic safety precautions should always be followed, 

including the following:
1.  Read and follow all instructions.

2.  This Control must be installed by a qualified electrician, according to National and Local Electrical Codes.

3.  Install this control not less than 5 feet (3 meters in Canada) from inside edge of pool. USE COPPER CONDUCTORS ONLY.

4.  Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.

5.  For Control grounding, bonding, installing and the wiring of underwater lights, refer to Article 680 of the National Electrical

  Code or Article 68 of the Canadian Electrical Code.

6.  The Control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly.

READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL