1.   Must be mounted upright. Antenna must be up.

2.   Radio receivers are sensitive to heat. Avoid mounting them 

above heaters, air conditioners or exposed to afternoon sun.

3.   The higher the receiver module, the longer its range. For 

good range and reliable reception, install modules as high as 

practical above ground level with the antenna at top.

4.   Large metal objects divert radio signals. Avoid mounting 

receiver modules on metal walls, fences or near large metal 

objects.

5.   Environmental conditions could effect the operation of the 

remote-control system. For example, in rain the range may 

be less than normal.

6.   

Certain electric equipment like brush type motors or 

electronic gas heater igniters emit radio signals and can 

effect the function of the receiver module. Avoid mounting 

modules near such equipment.

7.   To prevent electronic interference, install receiver modules at 

least 3 feet apart.

Make sure the intended load is within the capacity of the module, 

see ratings on page 1

.

1. 

 This module can be used to control either a 120 or 240 volt load. 

The NEUTRAL, however, must always be connected to the 

WHITE lead of the module.

 Refer to wiring diagrams on page 3.

2.   Select the proper location (see Useful Information above) and 

install receiver assembly on a vertical surface or other support, 

using hardware suitable for the purpose.

3.   Prepare the necessary conduit runs as required by the installation 

layout and pull in the specified conductors.

4.   Following wiring diagrams on page 3, make wire connections as 

shown.

5.   Turn ON power and test installation, using the ON/OFF button on 

face of the receiver module. Replace junction box cover, make 

sure the installation is secure.

6.   

To link transmitter button with the receiver, see operation 

instructions on page 3.

Содержание RC Series

Страница 1: ... National Electrical Code requirements This control should not be connected to any equipment which would cause bodily injury or property damage should it be activated unexpectedly Disconnect power at circuit breaker s or disconnect switch es before installing or servicing Test GROUND FAULT protection regularly If it fails to reset DO NOT USE THE POOL or SPA Contact a qualified service technician W...

Страница 2: ...f the receiver module Avoid mounting modules near such equipment 7 To prevent electronic interference install receiver modules at least 3 feet apart Make sure the intended load is within the capacity of the module see ratings on page 1 1 This module can be used to control either a 120 or 240 volt load The NEUTRAL however must always be connected to the WHITE lead of the module Refer to wiring diag...

Страница 3: ...ing each RC939 transmitter with the RC613 receiver Excluding a Transmitter Button Link from a Receiver Follow this procedure to exclude a transmitter button from a receiver 1 With a stylus or paper clip press the button on the side of the transmitter until the red LED illuminates 2 Momentarily press the configured ON OFF button on the transmitter that you want to exclude from the receiver 3 Moment...

Страница 4: ...d device is always ON and can t be turned OFF by the ON OFF button on the receiver Receiver is wired incorrectly Correct per installation diagram Faulty receiver Replace receiver Receiver clicks when its ON OFF button is pressed but the controlled device doesn t operate The controlled device is inoperative Perhaps due to a switch thermostat etc on the controlled device Determine what is preventing...

Отзывы: