Intermatic PJB2175 Скачать руководство пользователя страница 2

INSTALLATION PJB2175 & PJB4175

Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material 

contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.

INTERMATIC INCORPORATED,

 

SPRING GROVE, IL 60081-9698

http://www.intermatic.com

158PA13021 

 

 

 

 

 

 

 

 

 

  

       

ONE YEAR LIMITED WARRANTY

If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, except diverter seal, which is warrantied for the life 

of the product Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original household purchaser only 

and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; 

(b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) dam-

ages exceeding the cost of the product; (e) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear;

(f) transit damage, initial installation costs, removal costs, or reinstallation costs.

INTERMATIC  INCORPORATED  WILL  NOT  BE  LIABLE  FOR  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES.  SOME  STATES  DO  NOT  ALLOW  THE 

EXCLUSION  OR  LIMITATION  OF  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES,  SO  THE  ABOVE  LIMITATION  OR  EXCLUSION  MAY  NOT  APPLY  TO 

YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES.  ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF 

MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN 

THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW 

LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.

This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof 

of purchase, postage prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., 

Spring Grove, Illinois 60081-9698/815-675-7000  http://www.intermatic.com   Please be sure to wrap the product securely to avoid shipping damage.

TROUBLESHOOTING

SYMPTOM 

POSSIBLE CAUSE(S) 

CORRECTIVE ACTION

1. On light is OFF 

a. Burned - out bulb 

a. Replace bulb

   

b. Bad connection 

b. Correct defect

2. All lights are OFF 

a. Tripped breaker 

a. Reset breaker

   

b. Open GFCI 

b. Call Electrician

A wiring layout should be prepared ahead of the 

installation  of  this  Junction  Box  with  considera-

tions given to the following details.

1.  Installation shall be according to Article 

 

680 of the National Electric Code and all 

 

applicable local Codes. This Junction Box

 

is suitable for either line or low voltage 

 

luminaires.

2.  Use copper conductors only.

3.  This Junction Box will accommodate 

 

water resistant flexible cord, #16/3 or 

 

#14/3 Extra-hard usage (Type SOW, STW

 

or STOW) or, #12/3 or #10/2 Hard usage 

 

(Type SJW, SJTW or SJTWO).

4.  The Junction box must be rigidly 

 

supported and unused conduit openings 

 

permanently plugged with the plugs 

 

provided.

Installation

1.  Determine best location for the Junction Box and run 

properly sized conduits as per the wiring layout. 

The 

Junction Box shall be located not less than 4 feet 

from the inside wall of the pool. It must also be at 

least 8 inches above the maximum water level and 

not less than 4 inches above deck or grade. 

(See 

Illustration) Make sure the Junction Box can be rig-

idly supported. The optional mounting bracket (Model 

PA114) is designed to accommodate either wall or 

stake mounting.

2.  Cut off all conduits at the same level. Use reducer 

bushings furnished as needed for installation. For 1/2 

inch conduit, apply PVC Solvent Cement 1 inch down 

conduit and to small inside diameter of reducer bushing. 

Slide small end of reducer bushing over conduit to the 

stop tab. For 3/4 inch conduit, break the stop tab off of 

reducer bushing and PVC Solvent Cement large inside 

diameter of reducer bushing to conduit. PVC Solvent 

Cement large outside diameter of reducer bushings or 1 

inch conduit to Junction Box base. 

Permanently close 

all unused  conduit openings with the plugs provided. 

3.  An optional external bonding lug is provided. Connect to 

Equipotential Bonding Grid, if your installation requires it.

4.  Pull supply conductors from source and flexible cord 

from luminaires into Junction Box. Use twist on wire 

connectors or other approved termination method for 

power connections. Connect ground conductors and 

bonding conductors, if required, to ground bar. Tighten

 

terminal screws 35 in-lbs minimum. 

5.  Install strain reliefs. The direction that the clamps go on 

depends on the diameter of cable. For cables smaller 

than 1/2 inch (#16/3 or #12/3), install clamps with the 

arrow pointing down. For cables larger than 1/2 inch 

(#14/3 or #10/2) install clamps with the arrow pointing 

up. Tighten screws evenly until clamp bottoms out. If 

required, make bonding connections to the grounding 

bar and to external bonding lug.

6.  Check tightness of connections, make sure gasket is 

properly seated and close the Junction Box with the 

screws provided.

NOT LESS THAN 4FT.

TOP FACE OF JUNCTION BOX BASE

JUNCTION BOX

PLUGS

NOT LESS THAN 4”

NOT LESS THAN 8”

DECK