background image

LIMITED 1 YEAR WARRANTY

If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, 

free of charge. This warranty is extended to the original purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, 

dropping or abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; 

(c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs; (f) the finish on any portion of the 

product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.

INTERMATIC  INCORPORATED  WILL  NOT  BE  LIABLE  FOR  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES.  SOME  STATES  DO  NOT  ALLOW  THE  EXCLUSION 

OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY 

IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE 

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL 

BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED 

WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.

This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of pur-

chase, postage prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, 

Illinois 60081-9698/815-675-7000  http://www.intermatic.com  Please be sure to wrap the product securely to avoid shipping damage. 

158HL13183

THESE INSTRUCTIONS DO NOT COVER ALL VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR ALL SITUATIONS 

RELATED TO FIXTURE INSTALLATION, OPERATION OR MAINTENANCE. FOR FURTHER INFORMATION CONTACT YOUR 

DISTRIBUTOR OR INTERMATIC INCORPORATED - SPRING GROVE, ILLINOIS 60081 (815) 675-7000   www.intermatic.com

MOUNTING & WIRING (continued)

Select appropriate fixture wire to match incoming voltage. 

Models FL150MH & FL175MH are shipped with 277 V  
wire  ready  for  connections.  Models  FL150MHT  & 
FL175MHT  are  shipped  with  347  V  wire  ready  for 
connections. If supply voltage is lower, cap wire marked 
277 V (or 347 V for tri-tap models) with appropriate twist 
on  wire  connector  and  strip  fixture  wire  marked  with 
matching voltage.

Confirm  unused  voltage  fixture  wires  are  appropriately 

capped within fixture body.

Feed  the  matching  voltage  fixture  wire  through  the 

mounting arm.

Replace and secure reflector in the same orientation as 

shown in Figure 2.

Close  and  secure  lens  door  to  prevent  damage  while 

wiring fixture to mounting.

Connect the fixture wire matching the incoming voltage 

to the black (hot) supply wire.

Connect  the  fixture  wire  marked  COM  to  the  white 

(neutral) supply wire.

Connect  the  Green  (fixture  ground)  wire  to  the  supply 

grounding wire.

Make  sure  that  all  wires  and  connections  are  inside  the 
mounting wiring compartment and that the cover is properly 
sealed to keep moisture out.
Open lens door. Screw lamp into socket in lampholder until 
finger-tight.
Close  lens  door,  making  sure  that  gasket  is  in  place 
and  compressed  to  seal  out  moisture.  To  weatherproof 
fixture,  seal  all  holes  in  housing  (mounting  conduit,  plugs, 
photocontrols, etc.) with silicone sealant. 
To operate, restore power to the circuit and switch light on.

c.

d.

e.

f.

g.

h.

i.

j.

3.

4.

5.

6.

AIMING FIXTURE

  

 

WARNING 

  Electric shock hazard.

Do not turn mounting arm more than 360˚ after wires are 
connected. Excessive twisting of wires may loosen connections.

Turn off power at circuit breaker or fuse box. Rotate mounting 
arm  until  light  is  pointing  in  the  desired  direction.  Tighten 
locknut to secure.
Loosen mounting arm bolt (do not remove) and tip fixture to 
desired angle. Retighten bolt to secure.
Turn power on and check aim. If adjustment is needed, turn 
power OFF at circuit breaker or fuse box and allow fixture to 
cool before adjusting

LAMP REPLACEMENT

1.  Turn off power at circuit breaker or fuse box. Allow fixture and 

lamp to cool.

2.  Release  retaining  clip  and  swing  hinged  fixture  lens  door 

open . Remove old lamp and replace with new lamp of correct 
type and wattage. Screw lamp into socket in lampholder until 
finger-tight.

3.  Close and secure lens door, making sure that gasket is properly 

seated, free of debris, and compressed to seal out moisture.

4.  Turn power back on.
5.  Properly dispose of lamp per manufacturer’s recommendations.

1.

2.

3.

FL150MH  

(Metal Halide)

Figure 3

277 V
240 V

208 V

120 V

COM

IGN-02

X3

LAMP

X1

X3

COM

CAP

277 V

240 V

208 V

120 V

COM

LAMP

COM

FL175MH 

(Metal Halide)

Figure 4

FL150MHT 

(Metal Halide 

w/tri-tap)

Figure 5

347 V

277 V

120 V

COM

IGN-02

X3

LAMP

X1

X2

COM

CAP

347 V

277 V
120 V

COM

LAMP

COM

FL175MHT 

(Metal Halide 

w/tri-tap)

Figure 6

CAP

    

CAUTION

  (Metal Halide Lamps Only) 

Do not use lamp beyond manufactures rated life to reduce 
chance of lamp rupture.Turn lamp off at least once for 15 
minutes per week to reduce chance of lamp rupture.

    

CAUTION

 

Use lamp of correct type and wattage as specified on fixture.