background image

DAY

SWITCHING

“ON” OR “OFF”

SUN.

MON.

TUES.

WED.

THUR.

FRI.

SAT.

EVENT

TIMES

OPERATION

1

2

3

4

5

6

7

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Programming Steps

Refer to programming instructions in this manual or the abbreviated 
instructions on time switch door label and note the following:

The slide switch located on the right side is used to select automatic
operation (AUTO), manual operation (MANUAL) or to select 
programming (PROGRAM). The MANUAL position can be used to
temporarily override the program. Under normal operation, the 
selector should be in the AUTO  mode. The MANUAL mode maintains the
program but prevents the loads from automatically switching. 

FOR A

PROGRAM TO SWITCH LOADS AT THE CORRECT TIMES, THE
SELECTOR SWITCH MUST BE IN THE AUTO POSITION.

The left selector switch is used to select programming for the time of 
day and day of week (CLK) or select programming for the switch-
ing times (for both outputs independently OUTPUT1 or OUTPUT 2).

The RESET switch is used only prior to programming to reset the
microprocessor or to erase all programmed set points.

By holding the hour and/or minute buttons depressed, you can 
achieve a fast roll of the displayed time. This is useful when setting 
the time of day or programming set points (EVENTS).

UP to 10 ON and 10 OFF set points for both outputs combined or 
any combination up to 20 set points (EVENTS or momentary pulses) 
can be programmed and can be assigned to any or all 7 days for up 
to a maximum of 140 set points or pulses each week.

The load can be manually switched ON or OFF at any time if the
selector switch is in either the MANUAL or AUTO mode by pressing 
the ON/OFF button.The  left selector MUST BE IN OUTPUT 1 or 
OUTPUT 2 MODE.

Pressing the ON/OFF button two times in the PROGRAM mode 
causes the event time displayed to be removed from the program. 
The display will show “-:--”.

Programming

RESET TIME SWITCH: Press the recessed RESET switch to reset the
microprocessor and delete any set point information which has been
programmed. NOTE: DO NOT press RESET after programming has
begun or you will loose all of your program information.
TO SET TIME AND DAY OF WEEK: Place the right three position
selector in PROGRAM and the two left three position selector in CLK
mode. Press the HOUR, MINUTE and DAY buttons individually to
select the current time of day (12 hour AM/PM repeating) and the day
of the week. Day 1 is Sunday, day 2 is Monday, etc.
TO PROGRAM SET POINTS: Select PROGRAM mode with the right
selector and OUTPUT 1 or OUTPUT 2 mode with the left selector.
Press the HOUR and MINUTE buttons separately to program the first
set point time desired. Press the DAY button to select the day the 

FIG. #4

TIMER

POWER

BELL

LINE 1

LINE 2

LOAD

For ringing a bell (output 1)
and switching a motor load
(output 2) on different schedules.

LOAD STATUS INDICATOR

“ON” or “OFF”

DAY
INDICATOR

PROGRAM 

OUTPUT 

PROGRAM

CLOCK

LEFT SELECTOR

PROGRAM/

AUTOMATIC

MANUAL/OVER-

RIDE/RIGHT

SELECTOR

PROGRAMMING/
MANUAL LOAD
CONTROL
BUTTON

FIG. #6

PROGRAMMING

BUTTONS

Momentary Output 1
Maintained Output 2

TIMER

POWER

LINE 1

LINE 2

LOAD

LINE 

COIL

OFF 

ON 

COMMON

Output 1 “ON” times switch load ON
Output 2 “ON” times switch load OFF

For switching lighting contractor with
(shown) or WITHOUT self cleaning contacts.

FIG. #5

AM  ON

5 : 2 0

Содержание ET279C

Страница 1: ...ected loads 1 Follow all local electrical and safety codes National Electric Code NEC as well as Occupational Safety and Health Act OSHA 2 If the power disconnect point is out of sight lock it in the OFF position and tag it to prevent unexpected application of power 3 This time switch case must be grounded 4 Do not exceed the maximum current carrying capacity of this time switch 5 Always replace t...

Страница 2: ... making sure the display is visible If the display has scrambled information press the RESET switch and hold for three to five seconds Note that the battery can easily be replaced without removing the time switch mechanism or field wiring Simply press in and down ward in the direction of the arrow on the battery cover which is identified with the word Battery It is recommended that the battery be ...

Страница 3: ...tched ON or OFF at any time if the selector switch is in either the MANUAL or AUTO mode by pressing the ON OFF button The left selector MUST BE IN OUTPUT 1 or OUTPUT 2 MODE Pressing the ON OFF button two times in the PROGRAM mode causes the event time displayed to be removed from the program The display will show Programming RESET TIME SWITCH Press the recessed RESET switch to reset the microproce...

Страница 4: ...TATED ABOVE This warranty service is available by either a returning the product to the dealer from whom the unit was purchased or b mailing postage prepaid to the nearest authorized service center listed Please be sure to wrap the product securely when mailing to avoid damage This warranty is made by Intermatic Incorporated After Sales Service 7777 Winn Rd Spring Grove IL 60081 9698 815 675 7000 ...

Отзывы: