©2017 United Technologies Corporation                                                  2 / 2                                          P/N 466-5276 

• REV C • ISS 14FEB17      

 

 
 

LED 

Description 

D2 Red 

Blinks when sending data to control panel 

D4 Green 

Blinks when receiving data from control panel 

D9 Green 

Lit when power is on 

D8 Orange 

No function 

D7 Blue 

Blinks when valid packet received from sensor or keyfob 

D6 Green 

Blinks when valid packet received 

D14 Red 

Lit when relay is on 

D15 Red 

A triple blink every second indicates module not enrolled, a 
single blink every second indicates module is enrolled 

 
 
UM-W7 Programming 

 

Consult the UltraSync Modular Hub Reference Manual for programming the UM-W7. 
 

Note on Tamper 

 
Two rubber push buttons provide front case and rear wall tamper.  
 
To clear an Expander Tamper condition, both tamper inputs must be sealed. The 
enclosure should be firmly mounted on a flat surface with the cover closed. 
 
If either tamper input is open then an Expander Tamper condition will occur. 
 

Note on Relay Modes 

 
The receiver features one Single Pole Double Throw (SPDT) Form C relay. 

 

The relay is connected to output terminal J6 with Normally Open and Normally 
Closed connections for your convenience. 

 

The red LED (D14) lights up when the relay is energized. 

 

The relay can be configured in 3 different modes to support different applications. 
Use jumper on J5 to select the mode suitable for your requirements. 

 

 
 
 
 
 
 
 
 
 

 

Default is no jumper with relay in NC position. 

 

 

 

No Jumper 

Dry contact closure provided to output terminal. Maximum Load 30VAC @ 0.5A or 
30VDC @ 1A. 

 

Jumper between - and C 

Buss Ground provided to output terminal @ typical 0V. Do not exceed relay rating 
which is maximum load 30VAC @ 0.5A or 30VDC @ 1A.  

 

Jumper between C and + 

BUS Voltage is provided to output terminal @ typical 12-13VDC. Maximum Load @ 
12V is total panel current of 1,000 mA, this includes all connected devices such as 
keypads, cellular module, sirens and expansion modules. Do not exceed relay rating.

 

Adding and Removing Wireless Devices 

 

Refer to the UltraSync Modular Hub Reference Manual for adding and removing 
wireless devices. 

 

Completing Installation 

 

1. Re-install the front rubber tamper button if it was removed. 
2. Re-install the front plastic housing and tighten the bottom screw 

 

Warning: 

 

CHECK THE CURRENT REQUIREMENTS OF YOUR LOAD BEFORE CONNECTING. THERE IS NO OVERCURRENT PROTECTION ON 
THE RELAYS. YOU MUST ENSURE YOUR LOAD DOES NOT EXCEED THE RECEMMENDED LIMITS ABOVE. EXCEEDING LIMITS CAN 
DAMAGE THE MODULE AND POSE AN ELECTRICAL HAZARD THAT COULD RESULT IN A FIRE OR CAUSE SERIOUS ELECTRICAL 
SHOCK OR LOSS OF LIFE. 
THE ULTRASYNC MODULAR HUB HAS OVERCURRENT PROTECTION ON THE BUS AND MAY DISCONNECT THE BUS TO PROVIDE 
TEMPORARY PROTECTION. IF ENABLED, YOUR PANEL WILL REPORT “OVERCURRENT FAULT” OR “EXPANDER OVERCURRENT.”  
REPEATED OVERCURRENT CONDITIONS CAN RESULT IN PERMANENET DAMAGE TO THE PANEL OR CONNECTED DEVICES. 
 

Attention:  

VERIFIER LES CONDITIONS ACTUELLES DE VOTRE CHARGE AVANT DE CONNECTER. 
IL N'Y A PAS PROTECTION DE SURCHARGE SUR LES RELAIS. VOUS DEVEZ ASSURER VOTRE CHARGE NE DEPASSE PAS LES 
LIMITES SUGGERER CI-DESSUS. 
 SUPERIEURE LIMITES PEUVENT ENDOMMAGER LE MODULE ET POSE UN RISQUE ÉLECTRIQUE QUE POURRAIT CAUSER UN 
INCENDIE OU ENTRAÎNER UNE GRAVE ÉLECTROCUTION OU DES PERTES DE VIE. LE HUB UltraSync MODULAIRE A DE LA 
PROTECTION DE SURCHARGE SUR LE BUS DE COMMUNICATION POUR OFFRIR UNE PROTECTION TEMPORAIRE. SI ELLE EST 
ACTIVÉE, VOTRE GROUPE PRÉSENTERA SON RAPPORT "SURINTENSITÉ" OU "EXPANDER SURVOLTAGE." CONDITIONS DE 
SURINTENSITÉ RÉPÉTÉ PEUT ENTRAÎNER UN ENDOMMAGEMENT PERMENANT AU PANNEAU OU A DES APPAREILS 
CONNECTÉS. 

 

Specifications 

 

Compatibility 

UltraSync Modular Hub systems 

Frequency 

319.5 MHz 

UL/ULC Listed Voltage 

9.12 - 15 VDC 

Operational Voltage 

7.75 - 15 VDC  

Current 

40 mA Average 
65 mA Alarm/Maximum* 

*If relay is inactive, calculation can be de-rated 25 mA per inactive relay. If 
positive switching is utilized, additional current draw of connected load must be 
included in power budget calculations.

 

Operating 
temperature 
range 

Non UL/ULC installations 

14° to 131°F 

(-10° to 55°C) 

UL/ULC installations 

32° to 120° F 

(0° to 49° C) 

Storage temperature 

 

−30° to 120°F 

(−34° to 60°C) 

Relative 
humidity 

Non UL/ULC installations 

up to 95% noncondensing 

UL/ULC installations 

up to 85% noncondensing 

Product Dimensions 
(W x H x D) 

3.74” x 6.10 x 1.02” 
95mm x 155mm x 26mm 

 

Regulatory Information 

 

Manufacturer 

Placed on the market by: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, USA 

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in accordance with 
the instruction manual, may cause harmful interference to radio communications. 

If this equipment does cause harmful interference to radio or television reception, 
which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following 
measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the equipment and receiver.  
• Connect the equipment into an outlet on a circuit different from that to     
  which the receiver is connected.  
• Consult the dealer or an experienced radio/TV technician for help. 

This class B digital apparatus complies with Canadian ICES-3B. 
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du 
Canada. 

 

Contact Information 

For contact information, visit us online at www.interlogix.com. 
For technical support, see www.interlogix.com/support. 

 

Copyright 

Copyright © 2017 United Technologies Corporation. All rights reserved. 

 

Trademarks 

Interlogix is a registered trademark of United Technologies Corporation. Interlogix is part 
of UTC Climate, Controls & Security, a unit of United Technologies Corporation. 