background image

 

Important warning statements 

This carbon monoxide alarm is designed to detect carbon 
monoxide from ANY source of combustion. It is NOT designed 
to detect smoke, fire, or any other gas. 

WARNING: 

Carbon monoxide alarms are not smoke alarms. 

This carbon monoxide alarm is not a substitute for installing 
and maintaining an appropriate number of smoke alarms in 
your home.  
This CO alarm will not sense smoke, fire, or any poisonous gas 
other than carbon monoxide even though carbon monoxide 
can be generated by fire. For this reason you must install 
smoke alarms to provide early warning of fire and to protect 
you and your family from fire and its related hazards. 

Caution: 

This alarm will only indicate the presence of carbon 

monoxide at the sensor. Carbon monoxide may be present in 
other areas. 

WARNING: 

This product is intended for use in ordinary indoor 

locations of family living units. It is not designed to measure 
compliance with Occupational Safety and Health 
Administration (OSHA), commercial, or industrial standards. It 
is not suitable for installation in hazardous locations as defined 
in the National Electric Code.  
The installation of this device should not be used as a 
substitute for proper installation, use and maintenance of fuel 
burning appliances, including appropriate ventilation and 
exhaust systems. It does not prevent CO from occurring, nor 
can it solve an existing CO problem. 

WARNING: 

This device is designed to protect individuals from 

acute effects of carbon monoxide exposure. It may not fully 
safeguard individuals with specific medical conditions. 
If in doubt, consult a medical practitioner. Individuals with 
medical problems may consider using warning devices which 
provide audible and visual signals for carbon monoxide 
concentrations under 30 PPM. 

This carbon monoxide alarm requires a continuous supply of 
electrical power - it will not work without power. 

This alarm has not been investigated for carbon monoxide 
detection below 70 PPM. 

 

Contact information 

For servicing or contact information, see interlogix.com. 

For residential consumers, please contact your local security 
system installation company for product replacement service. 

Product returns from security professionals and installers 

Before you can return any product to UTC Fire & Security, you 
must obtain a return material authorization (RMA). This applies 
to all product returns, including warranty repair/replacements, 
non-warranty repairs, advance replacements, and credit 
returns. 

Security Customer Services: 
Phone: 888-437-3287 
FAX: 503-691-7566 
Email: [email protected] 

You will need to have the product and following information 
ready: 

• 

Original PO number (not required for distribution partners) 

• SKU/part 

number 

• Serial 

number 

Manufacturing information 

Manufactured by Interlogix, a UTC Fire and Security company, 
1275 Red Fox Road, Arden Hills, MN 55112. 

 

P/N 466-2393 • REV A • ISS 14FEB11 

 

7 / 8 

Содержание TX-6310-01-1

Страница 1: ...dwelling unit applications and other areas approved by the authority having jurisdiction AHJ It is not intended for use in industrial applications WARNING After seven years from initial power up this alarm will beep two times every 30 seconds to indicate that it is time to replace the alarm Replace the alarm immediately It will not detect CO in this condition To help identify the date to replace t...

Страница 2: ... Slide the alarm body back onto the mounting plate Note The mounting plate will not close if all three batteries are not installed Figure 4 Sliding the alarm on the mounting plate Alarm mounting guide Alarm mounting guide 5 Perform a sensor RF test with the control panel See RF communication test on page 3 When replacing the batteries use one of the following approved brands Duracell MN1500 or MX1...

Страница 3: ...u place your fingers over the sounder vent while testing your alarm Caution Continuous exposure to the high sound level of this alarm over an extended period of time may cause hearing loss The CO alarm provides three test modes Normal CO alarm test Conducts an internal self test and tests the sounder RF communication test Tests the communication path with the control panel CO alarm functional gas ...

Страница 4: ...1 Sensor Electrochemical Sensor life 7 years Frequency 319 5 MHz Supervisory interval 64 minutes Audible alarm Temporal 4 Alarm response times 70 PPM 60 240 min 150 PPM 10 50 min 400 PPM 4 15 min Dimensions 4 68 x 2 75 x 1 85 in 119 x 70 x 47 mm Storage temperature 4 to 140 F 20 to 60 C Operating environment Temperature Relative humidity 40 to 100 F 4 4 to 37 8 C 10 to 95 noncondensing 6 The contr...

Страница 5: ...arm Very low battery or unit malfunction Trouble condition trouble beeps every 60 seconds Replace batteries If condition continues unit has malfunctioned Replace immediately Unit will not respond to CO Test mode Red Alarm LED flashes with beeps Four quick beeps 5 seconds silence repeated once Normal operation when Test Hush button is pressed Sensor test mode CO not detected Alarm for test purposes...

Страница 6: ...tion of unvented fuel burning devices range oven fireplace etc Temperature inversions which can trap exhaust gasses near the ground Car idling in an open or closed attached garage or near a home What CO alarms can and cannot do CO alarms provide early warning of the presence of CO usually before a healthy adult would experience symptoms This early warning is possible however only if your CO alarm ...

Страница 7: ... from occurring nor can it solve an existing CO problem WARNING This device is designed to protect individuals from acute effects of carbon monoxide exposure It may not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon monoxi...

Страница 8: ...Alarm procedure 2533 7201 00 8 8 P N 466 2393 REV A ISS 14FEB11 ...

Отзывы: