background image

 

P/N 1072900A-EN 

• REV 

1.0 

• ISS 

27JAN15 

Accessing the web browser  

The on-

screen display

 

menus 

are available in English and 

Chinese. 

To access the web browser: 

1. 

Open the web browser and enter the IP address of 

the 

decoder 

(for example, http://192.168.1.70

). Press the 

Enter

 

key on the computer. The system displays the login 

window. 

2. 

Enter the user name (default: admin) and password 

(default: 1234) to log into the system. The main page of 

the decoder appears, which is 

Decoding Operation

 

by 

default (see

 Figure 3). 

Figure 3: TVE decoder main page 

  

1. 

Decoding Operation: 

Configures decoding resource, decoding

 

mode and video

 output. 

2. 

Configuration:

 

Configures device settings, network parameters,

 

alarm and user account.

 

3. 

Device management: 

Upgrades firmware, restores factory

 

default settings, and reboots the decoder.

 

Figure 4: Menu tree of the Decoding Operation 

Decoding Operation

Decode Mode

Decode Control

Decoding Status

Transparent Channel

Connection Status

Decoding Channel

Display Channel

Ch Enable/Disable

Picture Overlay

Dynamic Decoding
Sequence Decoding
Remote Playback
Display Control

 

Table 1: Description of the Decoding Operation menus 
Function  

Description  

Decode 

Mode  

Select

 decoding channels and 

sequence

.  

• 

 

Configure playback

 on 

recorded files. 

 

• 

 

Configure

 

display channel, video format, output 

resolution and display mode

Decode 

Control  

Enable/disable a decoding channel, scale video 

output image, and configure picture overlay.

  

Function  

Description  

Decoding 

S

tatus  

Dis

play

 the decoding channel status and video 

output status.  

Transparent 

Channel  

Set up

 transparent data 

transmission 

between the 

encoder and decoder. 

Configuration 

Use these menus to configure the decoder.

 

Figure 5: Menu tree of Configuration 

Configuration

Device Properties

Time Settings
Network Settings

Serial Port Settings

Alarm Settings

Arming Time
User Management
Config File Import

/

Export

RS

-232 Port

RS

-485 Port

Alarm Input
Alarm Output

General

DDNS

Telnet

 

Table 2: Description of the Configuration menu tree 
Function  

Description  

Device Properties  

Define the decoder name. 

 

Display the decoder serial number and 

firmware version. 

 

Time S

ettings  

Define the 

device 

time 

 

Network Properties  

Define network settings

Serial 

Port 

S

ettings  

Define the serial port 

properties. 

Alarm S

ettings  

Configure

 

alarm input/output

 settings 

and notification method. 

 

Arming 

T

ime 

 

D

efine alarm s

chedules.  

User M

anagement 

 

Create, modify

 or delete users and 

allocate user permissions. 

 

Config 

File 

Import/

E

xport

 

Import/export configuration files.

 

Specifications 

Power supply 

 

12 VDC

 

Consumption

 

M

ax.

 

15W

 

Operating temperature

 

-10  to +55 °C (14 to 131 °F) 

Operating humidity 

 

10% to 90% 

Dimensions

 

(W ×D × H)

 

220 

× 

180 

× 

45 

mm

   

(8.66 

×

 7.09 

×

 1.77 in.) 

Weight 

 

1.12 kg (2.47lbs) 

Contact information 

For contact information, see www.interlogix.com or

 

www.utcfssecurityproducts.eu.

 

All manuals and user guides at all-guides.com