14
Installation Guide
Operating temperature range
The operating temperature of the TVD-2402/4402
and TVD-2404/4404 cameras is -30 to +60 °C (-22
to +140 °F).
When the camera initially starts up, the heater will
start to work automatically when the temperature is
below -10 °C (14
°F). However, with continuous
operation the heater will not work until the internal
temperature drops below -30°C (-22 °F). It will then
be disabled when the temperature reaches -10 °C
(14 °F)
. The heater only work
s under 24 VAC.
Program
Once the camera hardware has been installed, you
can then program the camera.
The camera has a built-
in OSD button and supports
UtC (Up-to-
Coax) control over both CVBS and TVI
outputs.