Figure 5: Mounting on concrete
Always use a DV1202A mounting plate. The expansion plug must
penetrate at least 50 mm into the concrete. Please follow the steps
shown in Figure 6 if you are installing the test transmitter DV1215A.
$
For the equipment to conform to CEI standard 79-2, the
DV1215A test transmitter must be installed.
Figure 6: Control and function test
Using a voltmeter, check the background signal level in the detector
to prevent nuisance alarms. Set the sensitivity to Gmax during the
test.
DV1201A
DV1221A
Measure
0.7 V
0 V
None
1.4 V
2 V
Reduce range/remove source
$
Try to remove the source of ambient noise instead of
reducing the range.
Functional testing with hand tester DV1230
!
and mechanical
tool
"
:
DV1201A
DV1221A
Alarm in 30 sec.
Alarm in 45 sec.
Alarm after 5 blows
NA
Detection range (in foot):
Technical specifications:
Input power:
9-15 VDC
2 V max. ripple pp
Current consumption:
Nom. 8.6 mA
Alarm output:
Form C solid state relay, max. series
resistance 35 Ohm
Alarm indication:
LED-ind. output 3
Sensitivity:
5 steps of 6 dB each
Range:
See Table “Detection range”
Sabotage protection:
Temp. 183.2 °F
drill shield,
opening/pry-off contact,
Low voltage alarm:
7.5 V
Temperature limits:
-4 °F to + 131 °F
Dimensions:
3.93 x 3.15 x 1.30 inches
Colour:
Grey, RAL 7035
Weight:
0.86 lb
Concrete
13.12
45.93
45.93
Steel
1/G
max
26.25
45.93
45.93
Brick
9.84
26.25
26.25
Concrete
9.84
29.53
29.53
Steel
2/G
ref
13.12
29.53
29.53
Brick
3.28
19.69
19.69
Concrete
6.56
19.69
19.69
Steel
3/G
min
6.56
19.69
19.69
Brick
-
13.12
13.12
Concrete
3.28
16.40
16.40
Steel
4
3.28
16.40
16.40
Brick
-
9.84
9.84
Concrete
-
13.12
13.12
Steel
5
-
13.12
13.12
Brick
-
6.56
6.56
Sensitivity
setting
Material
Thermal
lance
Diamond
disk
Drilling