background image

1

 

 

P/N 0320-7201-00 • REV A • ISS 14MAR18                      ©2018 United Technologies Corporation

  

Attention:

 Please take a few minutes to thoroughly read this user guide which should be 

saved for future reference.

NOTE:

 Leave this user guide with the home owner.

You do NOT need a home wi-fi system to use these units. Multiple wireless units create 

their own independent wireless alarm network.

SDX-135Z-433

Wireless Interconnected Smoke/Heat/ 

Freeze sensor 433-63

User Guide

Содержание SDX-135Z-433

Страница 1: ...y read this user guide which should be saved for future reference NOTE Leave this user guide with the home owner You do NOT need a home wi fi system to use these units Multiple wireless units create their own independent wireless alarm network SDX 135Z 433 Wireless Interconnected Smoke Heat Freeze sensor 433 63 User Guide ...

Страница 2: ...work Teach children how to respond to the alarm and that they should never play with the unit Your Interlogix smoke alarm was designed for use in a residential environment It is not designed for use in a recreational vehicle RV or boat NOTE Please thoroughly read this user guide and save the document for future reference and to pass on to any subsequent owner The manufacturer recommends replacing ...

Страница 3: ...commended Locations For Smoke Alarms 14 7 Locations To Avoid 16 8 Installation Activation Wireless 17 8 1 Set Up A Wireless Alarm Network Wireless Interconnect 18 8 2 Adding Alarms to an Existing Wireless Interconnected Network 20 8 3 Resetting an Alarm s Wireless Interconnect Settings 21 9 Operation and Testing 22 10 Recognizing Nuisance Alarms 23 11 Battery 24 12 Permanently Disable Alarm Discha...

Страница 4: ...Instead use your alternate exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in If the escape route requires you to go through smoke stay close to the floor where the air is cleaner Crawl if necessary and breathe shallowly through a cloth wet if possible Once outside go to your selected meeting place and make ...

Страница 5: ... 2 alarm chirps when System Test mode enabled Hold magnet next to button for 4 seconds See Figure 5 Local Alarm Test button press when no alarm condition is present Flashes RED AMBER GREEN then current protocol Temporal T3 pattern Allow completion of test or perform button press to cancel return to normal operation System Alarm Test button press in System Test Mode when no alarm condition is prese...

Страница 6: ...nown alarm condition such as smoke from cooking activates the alarm Locate None After button push on non initiating unit only initiating unit continues alarm pattern Use this to quickly locate the alarm source and determine if alarm is nuisance or real Initiating Alarm Alarm multiple alarms in an interconnected system Green LED blinks once per sec indicating that this is the unit initiating the al...

Страница 7: ... the device in a different orientation on the mounting bracket This might align the antenna in a better position 1 Push the Test Hush button once to silence the audible indication for 24 hours at a time The RED LED will blink out an Error Code number of blinks when the Test Hush button is pushed released once Report the number of blinks to Customer Service if needed 2 Follow instructions in Resett...

Страница 8: ...s Sensor Clean liness Level Clean Me Indication AMBER LED Clean Me blink sequence after TESTING PUSH TO TEST BUTTON temporal pattern per Operation and Testing None 1 Push the Test Hush button to initiate alarm test Following the temporal patterns the AMBER LED will blink the cleanliness status of the alarm 0 1 Unserviceable fault remove discharge and replace the alarm 2 3 Insensitive requires clea...

Страница 9: ...alarms Up to 24 alarms can be a part of the same interconnected network The SDX 135Z 433 uses 10 year sealed in lithium batteries ensuring continuous operation over the 10 year life of the alarm This eliminates worry about battery removal or unauthorized deactivation of the alarm The self activation feature activates the alarm when attached to the mounting bracket At the end of alarm life the unit...

Страница 10: ...hermistor Battery life 10 years Alarm life 10 years Audible alarm Smoke heat 85dB at 10 3 0 to 3 5 KHz pulsing alarm Temporal T3 pattern Single Unit Box Dimensions 142mmx149mm x 65mm W x L x H Product Dimensions Ø142 3 0 3mm x 59 0 1 0mm Smoke Sensitivity 2 32 1 35 ft obscuration Gross Weight unit pkg etc 465 grams Net Product Weight 340 grams Product Features and Specifications ...

Страница 11: ...5 F 29 4 C Fixed temperature heat detection 135 F 57 2 C Freeze warning 41 F 5 C 5 F 2 8 C Storage temperature 4 F 20 C to 140 F 60 C Operating environment Temperature Relative humidity 32 F to 100 F 0 C to 37 8 C 0 to 95 noncondensing Regulatory Listings UL217 3 year warranty Not a battery performance claim Product Features and Specifications ...

Страница 12: ...R18 2018 United Technologies Corporation Model Description SDX 135Z 433 Wireless Interconnected Smoke Heat Freeze sensor 433 63 UL217 Accessories SM 200 Smoke In A Can canned smoke for functional testing of smoke alarms Product Ordering ...

Страница 13: ...an occur within the home Ionization sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than pho toelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms A battery powered alarm must have a battery of the specified type in good condition and installed properly This m...

Страница 14: ...ed The closed door may prevent an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential construction When mounting an alarm on the ceiling locate it at a mi...

Страница 15: ...rms and smoke detectors on tray shaped ceilings ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped ceilings ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped ceilings ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped ceilings Figure 1 F...

Страница 16: ...perature may fall below 32ºF 0C or rise above 100ºF 37 8C such as garages and unfinished attics Alarms should not be installed within 3 ft 9m of the door to a bathroom containing a tub or shower forced air supply ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas Do not install near vents flues chimneys or any forced unforced air ventilation open...

Страница 17: ...ate by rotating the alarm in a clockwise direction NOTE Installing the alarm on the mounting bracket trim plate will automatically activate the battery The power up sequence is indicated by the LED ring slowly glowing GREEN on off one time NOTE Alarms will emit a series of slow RED LED glowing on off as the alarm searches for a wireless network If you are intending to use the alarms without the wi...

Страница 18: ...aken within 15 minutes of initial power up the wireless function will turn off The alarm will then perform as a single station alarm WIRELESS These models have wireless alarm interconnect capability When one interconnected alarm sounds an alarm all other compatible wireless alarms in the wireless alarm network will alarm A maximum of 24 compatible devices may be interconnected in a multiple statio...

Страница 19: ... network setup to timeout approximately 15 minutes OR to immediately close the network push the Test Hush button until two beeps are heard approximately 4 seconds and then release the button The network can be closed from any device enrolled in the network When the network has been closed each alarm s GREEN LED will change from glowing on off every second to flashing once every 60 seconds to indic...

Страница 20: ...rim plate to activate the battery or by carefully turning the red activation wheel with a screwdriver See Figure 4 After initial GREEN LED on off sequence the new alarm s RED LED will fade on off every 3 sec onds as it searches for the network A fast GREEN LED flickering followed by a slow GREEN LED fading on off confirms the new alarm has found and joined the existing wireless interconnection net...

Страница 21: ... the out of box mode 1 Place and hold a magnet for 4 seconds on the cover at the designated location per Figure 5 The alarm will chirp once when the magnet is detected then the alarm will chirp twice and the button will start flashing the RED LED rapidly to indicate System Test Mode has been entered 2 Press and hold the Test Hush button for approximately 8 seconds while the RED LED is rapidly flas...

Страница 22: ...it for four seconds until the alarm chirps twice and the RED LED begins blinking rapidly and then press and release the Test Hush button All alarms will perform a self test WARNING Due to the loudness 85 decibels of the alarm always stand about 2 5 ft 0 7M away from the alarm or use ear protection when testing WARNING DO NOT use an open flame to test your alarm You could damage the Alarm or ignite...

Страница 23: ...f combustible particles are generated from spills or when broiling Using the fan on a range hood which vents to the outside non recirculating type will also help prevent nuisance alarms from occurring by removing these combusti ble products from the kitchen Locate In an interconnected system all alarms will be alarming together an alarm that detects smoke or heat and initiates an alarm is called t...

Страница 24: ...UTION THE BATTERY USED IN THIS DEVICE MAY PRESENT A FIRE OR CHEMICAL BURN HAZARD IF MISTREATED DO NOT RECHARGE DISASSEMBLE HEAT ABOVE 100 C 212 F OR DISPOSE OF IN FIRE Low battery This alarm is equipped with a low battery monitor circuit If the battery capacity can no longer provide adequate power for all alarm functions the low battery condition will occur See Troubleshooting Guide The alarm batt...

Страница 25: ...or reactivated WARNING Failure to discharge alarm battery as instructed prior to disposal may create poten tial for lithium battery related fire or hazard CAUTION Do not disassemble and do not dispose of in fire To Permanently Disable Alarm Discharge Battery Rotate the alarm counterclockwise to remove it from the mounting plate Push in the dashed area with a screwdriver to break tab Figure 6 After...

Страница 26: ...est sequence the alarm may be in need of cleaning After cleaning press the Test Hush button If the fault does not clear the alarm needs to be replaced Never use detergent or other solvents to clean the alarm Avoid spraying air freshener hair spray or other aerosols near the alarm Do not paint the alarm Paint will seal the vents and interfere with the sensor s ability to detect smoke Never attempt ...

Страница 27: ...sted Install and maintain fire extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires Victims are often intimate with the fire too old or young or physically or mentally impaired such that they ca...

Страница 28: ...e alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recom mended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room and hallways not pr...

Страница 29: ... radio or television reception the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for he...

Страница 30: ... ALL WARRANTIES AND REPRESENTATIONS WHETHER EXPRESS IMPLIED STATUTORY OR OTHERWISE INCLUDING BUT NOT LIMITED TO ANY WAR RANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THESE PRODUCTS AND ANY RELATED SOFTWARE MANUFACTURER FURTHER DISCLAIMS ANY OTHER IMPLIED WARRANTY UNDER THE UNIFORM COMPUTER INFOR MATION TRANSACTIONS ACT OR SIMILAR LAW AS ENACTED BY ANY STATE USA onl...

Отзывы: