LCD Keypad 

11

DISPLAY TEST FUNCTION 

This function will perform a test of the LCD display.  No alarms or reports will be 
sent. 

1. Press 

[

U

] [4] [5]. The test will be performed and all of the display pixels and 

keys will flash until another key is pressed. 

2.  Press any key to end the test. 
 
 

LIGHT CONTROL FOR X-10 DEVICES (Optional, if programmed) 

This menu allows you to control up to ten X-10 devices from each keypad. 

1. Press 

[

U

] [4] [6]. The screen will prompt you to “Select Light Number 0 - 9”. 

2. 

Enter the number of the X-10 device you want to control.  The LCD screen will 
show the light number on the left.  On the right side of the display it will 
prompt you to turn the light (X-10 device) “On” or “Off”. 

3. Press 

[

x

] to turn the X-10 device “On” or press [

y

] to turn the X-10 device 

“Off”. 

4.  The LCD screen will again prompt you to “Select Light Number 0 - 9”. 

5.  Repeat Steps 2 and 3 until complete. 

6. Press 

[#] to exit from the X-10 menu. 

 
 

CHANGE LANGUAGES 

This function allows you to switch between the two languages programmed in your 
keypad.  NOTE:  You must exit any other function mode before attempting to 
change languages. 

1. Press 

[

U

] [4] [9]. The LCD keypad is now toggled to the second language. 

2.  Repeat Step 1 to revert to the first language. 
 
 

CHANGING USER CODES 

1. Press 

[

U

] [5]. The LCD Screen will prompt for a code. 

2. Enter 

[master code].  The LCD Screen will prompt for a user number. NOTE: 

For partitioned systems, if you are changing the code of another person, 
you must have access to all partitions, or at least all of the partitions to 
which the other person has access. 

Содержание NX-1248E

Страница 1: ......

Страница 2: ...hen the system is armed in the NIGHT mode It is off when the system is disarmed The NIGHT key will flash when there has been an alarm during the previous arm cycle The BYPASS key is illuminated when a...

Страница 3: ...10 SETTING THE KEYPAD TONE 10 VIEW ALARM MEMORY 10 TEST FUNCTION 10 DISPLAY TEST FUNCTION 11 LIGHT CONTROL FOR X 10 DEVICES 11 CHANGE LANGUAGES 11 CHANGING USER CODES 11 ASSIGNING USER CODE AUTHORITY...

Страница 4: ...e your system KEEP IN MIND THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this...

Страница 5: ...under duress Forced Arming An option that allows the system to be turned on ARMED with one or more zones open A system that is ready to be force armed will flash the entire message System Not Ready Fo...

Страница 6: ...y zone in this keypad s partition is bypassed If the BYPASS key is off no zones are bypassed EMERGENCY ACTIVATION KEYS NOTE You must press and hold these keys for 2 seconds to activate these functions...

Страница 7: ...when the user is going away from the premise and wants the interior protected 1 Close all protected doors and windows T The System Ready message will be displayed when all protected zones and sensors...

Страница 8: ...If any zones are bypassed a sensor in that zone can be violated without affecting the ready status T The security system will not arm if the System Not Ready message is displayed It can be force arme...

Страница 9: ...m in the AWAY STAY NIGHT modes by pressing the corresponding AWAY STAY NIGHT key twice This feature is used for ARMING ONLY and will not disarm the security system This is ideal for a maid or baby sit...

Страница 10: ...dure B If you know the number of the zone to bypass 1 Press BYPASS 2 When the LCD prompts for a code optional if programmed enter your user code 3 The bypass light flashes 4 Enter the zone you wish to...

Страница 11: ...s and the corresponding numbers associated with those functions 2 Press the number listed on the display in order to access that particular function Hint If you already know the function numbers simpl...

Страница 12: ...ress to set this tone and exit from the Adjust Tone mode VIEW ALARM MEMORY 1 Press U 3 to display the zone s on the keypad that created the last alarm 2 The LCD Screen will display the zone descriptio...

Страница 13: ...0 device On or Off 3 Press x to turn the X 10 device On or press y to turn the X 10 device Off 4 The LCD screen will again prompt you to Select Light Number 0 9 5 Repeat Steps 2 and 3 until complete 6...

Страница 14: ...LS Assign authority levels to users by following the steps below Assign user codes before assigning authority levels NOTE You must have authority to the partition you wish to add or remove from anothe...

Страница 15: ...t Smoke Detectors Zone Troubles and Zone Tampers 1 Disarm the system if it is not already disarmed 2 Press U 7 Resets have now been performed 3 If the keypad begins beeping the reset did not execute p...

Страница 16: ...JUSTING THE VIEW BRIGHTNESS OF THE LCD 1 Enter U 9 1 The LCD will prompt for a code 2 Enter master code The LCD will prompt you to raise or lower the view 3 Use x y to raise or lower the viewing angle...

Страница 17: ...o understand the various messages displayed on your keypad screen INDICTORS IN THE PARTITIONING MASTER MODE T BYPASS will illuminate if ANY area has a zone bypassed T AWAY will illuminate steady if AL...

Страница 18: ...ND DISARMING MULTIPLE PARTITIONS To arm disarm multiple partitions enter a code that has arm disarm authority for ALL of the partitions to be armed disarmed The following display will appear on the LC...

Страница 19: ...armed and disarmed states of an individual area press U Area number To operate an individual area enter the number of the partition you wish to operate The LCD keypad will now operate as a single area...

Страница 20: ...g has not been selected T Beeps 1 second for the CHIME feature T Beeps 1 second at the end of the exit delay T Beeps to indicate telephone line fault if selected T Beeps rapidly to alert you that ther...

Страница 21: ...press RQWURO R WDPSHU Optional The Box Tamper circuit has activated RQWURO DLO WR RPP The control attempted to communicate a message to the Central Station but was unsuccessful RQWURO URXQG IDXOW A sh...

Страница 22: ...HU FXUUHQW A short circuit of an expansion devices power supply has occurred SDQVLRQ 3RZHU WURXEOH The main power to an expansion power supply is not on SDQVLRQ 3RZHU WURXEOH The main power to an expa...

Страница 23: ...ce is not reporting to the control Duress Duress The control has been armed or disarmed with a Duress code Man Fire Manual Fire Keypad Fire has been activated Aux 2 Auxiliary 2 Keypad Medical has been...

Страница 24: ...ession is started End Dnld End Download Download session is ended Cancel Cancel System is disarmed and the Cancel button was pressed within 5 minutes of an alarm Gnd Flt Ground Fault A short to ground...

Страница 25: ...site Code Entry Code Entry A code has been entered First Open First Open Reports when the first partition is disarmed Last Close Last Close Reports when the last partition is armed Sprnklr Sprinkler I...

Страница 26: ...outdoors for a headcount of the building occupants Practice escape procedures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If...

Страница 27: ...LCD USERS MANUAL 1248EUA01 REV A 08 20 01...

Отзывы: